Literature DB >> 31440962

Simultaneous reconstruction of multiple stiff wires from a single X-ray projection for endovascular aortic repair.

Katharina Breininger1, Moritz Hanika2, Mareike Weule2, Markus Kowarschik2, Marcus Pfister2, Andreas Maier3.   

Abstract

PURPOSE: Endovascular repair of aortic aneurysms (EVAR) can be supported by fusing pre- and intraoperative data to allow for improved navigation and to reduce the amount of contrast agent needed during the intervention. However, stiff wires and delivery devices can deform the vasculature severely, which reduces the accuracy of the fusion. Knowledge about the 3D position of the inserted instruments can help to transfer these deformations to the preoperative information.
METHOD: We propose a method to simultaneously reconstruct the stiff wires in both iliac arteries based on only a single monoplane acquisition, thereby avoiding interference with the clinical workflow. In the available X-ray projection, the 2D course of the wire is extracted. Then, a virtual second view of each wire orthogonal to the real projection is estimated using the preoperative vessel anatomy from a computed tomography angiography as prior information. Based on the real and virtual 2D wire courses, the wires can then be reconstructed in 3D using epipolar geometry.
RESULTS: We achieve a mean modified Hausdorff distance of 4.2 mm between the estimated 3D position and the true wire course for the contralateral side and 4.5 mm for the ipsilateral side.
CONCLUSION: The accuracy and speed of the proposed method allow for use in an intraoperative setting of deformation correction for EVAR.

Entities:  

Keywords:  EVAR; Fluoroscopy; Guide wire reconstruction; Image guidance

Mesh:

Year:  2019        PMID: 31440962     DOI: 10.1007/s11548-019-02052-7

Source DB:  PubMed          Journal:  Int J Comput Assist Radiol Surg        ISSN: 1861-6410            Impact factor:   2.924


  22 in total

1.  Three-dimensional guide-wire reconstruction from biplane image sequences for integrated display in 3-D vasculature.

Authors:  Shirley A M Baert; Everine B van de Kraats; Theo van Walsum; Max A Viergever; Wiro J Niessen
Journal:  IEEE Trans Med Imaging       Date:  2003-10       Impact factor: 10.048

2.  Patient-Specific Finite-Element Simulation of the Insertion of Guidewire During an EVAR Procedure: Guidewire Position Prediction Validation on 28 Cases.

Authors:  J Gindre; A Bel-Brunon; M Rochette; A Lucas; A Kaladji; P Haigron; A Combescure
Journal:  IEEE Trans Biomed Eng       Date:  2016-07-07       Impact factor: 4.538

3.  Source of errors and accuracy of a two-dimensional/three-dimensional fusion road map for endovascular aneurysm repair of abdominal aortic aneurysm.

Authors:  Claude Kauffmann; Frédéric Douane; Eric Therasse; Simon Lessard; Stephane Elkouri; Patrick Gilbert; Nathalie Beaudoin; Marcus Pfister; Jean François Blair; Gilles Soulez
Journal:  J Vasc Interv Radiol       Date:  2015-02-24       Impact factor: 3.464

4.  Guide wire reconstruction and visualization in 3DRA using monoplane fluoroscopic imaging.

Authors:  Theo van Walsum; Shirley A M Baert; Wiro J Niessen
Journal:  IEEE Trans Med Imaging       Date:  2005-05       Impact factor: 10.048

5.  Multimodality 3D-roadmap for cardiovascular interventions in congenital heart disease--a single-center, retrospective analysis of 78 cases.

Authors:  Martin Glöckler; Julia Halbfaβ; Andreas Koch; Stephan Achenbach; Sven Dittrich
Journal:  Catheter Cardiovasc Interv       Date:  2013-03-18       Impact factor: 2.692

6.  Semi-automatic catheter reconstruction from two views.

Authors:  Matthias Hoffmann; Alexander Brost; Carolin Jakob; Felix Bourier; Martin Koch; Klaus Kurzidim; Joachim Hornegger; Norbert Strobel
Journal:  Med Image Comput Comput Assist Interv       Date:  2012

7.  Iliac artery deformation during EVAR.

Authors:  Giasemi Koutouzi; Marcus Pfister; Katharina Breininger; Mikael Hellström; Håkan Roos; Mårten Falkenberg
Journal:  Vascular       Date:  2019-03-27       Impact factor: 1.285

8.  Automatic detection of selective arterial devices for advanced visualization during abdominal aortic aneurysm endovascular repair.

Authors:  Simon Lessard; Claude Kauffmann; Marcus Pfister; Guy Cloutier; Éric Thérasse; Jacques A de Guise; Gilles Soulez
Journal:  Med Eng Phys       Date:  2015-09-09       Impact factor: 2.242

9.  A Numerical Preoperative Planning Model to Predict Arterial Deformations in Endovascular Aortic Aneurysm Repair.

Authors:  Hossein Mohammadi; Simon Lessard; Eric Therasse; Rosaire Mongrain; Gilles Soulez
Journal:  Ann Biomed Eng       Date:  2018-07-11       Impact factor: 3.934

10.  Robust and semantic needle detection in 3D ultrasound using orthogonal-plane convolutional neural networks.

Authors:  Arash Pourtaherian; Farhad Ghazvinian Zanjani; Svitlana Zinger; Nenad Mihajlovic; Gary C Ng; Hendrikus H M Korsten; Peter H N de With
Journal:  Int J Comput Assist Radiol Surg       Date:  2018-05-31       Impact factor: 2.924

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.