Safety and efficacy of prophylactic resorbable biosynthetic mesh following midline laparotomy in clean/contemned field: preliminary results of a randomized double blind prospective trial.

F Pizza1, D D'Antonio2, M Arcopinto3, C Dell'Isola4, A Marvaso2.   

Abstract

BACKGROUND: Incisional hernia (IH) is one of the most common sequelae of laparotomy.
MATERIALS AND METHODS: We present a double-blind randomized study examining feasibility, safety and incisional hernia rate using a prophylactic Bio-A biosynthetic stripe (Gore) in a sub-lay position after midline laparotomy in patients undergoing operations in clean-contaminated and contaminated field. One hundred patients who underwent a midline laparotomy of at least 10 cm in a clean-contaminated and contaminated field were considered. Patients were divided into two groups: [Group A closed in double layer using PDS 0 with WL/SL of 1:4; Group B closure in double layer using PDS 0 and sub-lay positioning a 3 cm-wide BIO A (Gore) strip extended for the entire length of the incision]. The primary objective of the study was to identify IH rate in the two groups at 1- and 2-year follow-up. Secondary objective was to identify any differences in the two groups in terms of post-operative pain, morbidity and mortality.
RESULTS: Out of a total of 100 patients included in the study, a 2-year follow-up was possible for 47 patients in group A and 45 in group B. The incidence of IH was 11/47 in group A (22%) and 3/45 in group B (6%) [p < 0.01]. Furthermore, no statistically significant difference was noted about post-operative morbidity and pain related to the wall closure method.
CONCLUSIONS: The prophylactic use of a BIO-A biosynthetic stripe (Gore) showed a statistically significant reduction in the incisional hernia rate in patients who underwent clean-contaminated and contaminated surgery.

Entities:  

Keywords:  Incisional hernia; Prophylactic mesh; Resorb able mesh

Year:  2019        PMID: 31432287     DOI: 10.1007/s10029-019-02025-4

Source DB:  PubMed          Journal:  Hernia        ISSN: 1248-9204            Impact factor:   4.739


  38 in total

1.  Prospective clinical trial of factors predicting the early development of incisional hernia after midline laparotomy.

Authors:  Radovan Veljkovic; Mladjan Protic; Aleksandar Gluhovic; Zoran Potic; Zoran Milosevic; Alexander Stojadinovic
Journal:  J Am Coll Surg       Date:  2010-02       Impact factor: 6.113

2.  Comparison of ultrasonography and physical examination in the diagnosis of incisional hernia in a prospective study.

Authors:  A Bloemen; P van Dooren; B F Huizinga; A G M Hoofwijk
Journal:  Hernia       Date:  2011-08-11       Impact factor: 4.739

3.  Infected large pore meshes may be salvaged by topical negative pressure therapy.

Authors:  F Berrevoet; A Vanlander; M Sainz-Barriga; X Rogiers; R Troisi
Journal:  Hernia       Date:  2012-07-27       Impact factor: 4.739

Review 4.  Prophylactic mesh placement in high-risk patients undergoing elective laparotomy: a systematic review.

Authors:  Subramanian Nachiappan; Sheraz Markar; Alan Karthikesalingam; Alan Karthikesaligam; Paul Ziprin; Omar Faiz
Journal:  World J Surg       Date:  2013-08       Impact factor: 3.352

5.  Long-term complications associated with prosthetic repair of incisional hernias.

Authors:  G E Leber; J L Garb; A I Alexander; W P Reed
Journal:  Arch Surg       Date:  1998-04

6.  Absorbable Polyglactin vs. Non-Cross-linked Porcine Biological Mesh for the Surgical Treatment of Infected Incisional Hernia.

Authors:  Yohann Renard; Louis de Mestier; Julie Henriques; Paul de Boissieu; Philippe de Mestier; Abe Fingerhut; Jean-Pierre Palot; Reza Kianmanesh
Journal:  J Gastrointest Surg       Date:  2019-01-22       Impact factor: 3.452

7.  Outcomes of synthetic mesh in contaminated ventral hernia repairs.

Authors:  Alfredo M Carbonell; Cory N Criss; William S Cobb; Yuri W Novitsky; Michael J Rosen
Journal:  J Am Coll Surg       Date:  2013-09-14       Impact factor: 6.113

8.  Prophylactic Intraperitoneal Onlay Mesh Reinforcement Reduces the Risk of Incisional Hernia, Two-Year Results of a Randomized Clinical Trial.

Authors:  Philippe Brosi; Philippe M Glauser; Benjamin Speich; Samuel A Käser; Christoph A Maurer
Journal:  World J Surg       Date:  2018-06       Impact factor: 3.352

9.  Meta-analysis of techniques for closure of midline abdominal incisions.

Authors:  M van 't Riet; E W Steyerberg; J Nellensteyn; H J Bonjer; J Jeekel
Journal:  Br J Surg       Date:  2002-11       Impact factor: 6.939

Review 10.  2017 update of the WSES guidelines for emergency repair of complicated abdominal wall hernias.

Authors:  Arianna Birindelli; Massimo Sartelli; Salomone Di Saverio; Federico Coccolini; Luca Ansaloni; Gabrielle H van Ramshorst; Giampiero Campanelli; Vladimir Khokha; Ernest E Moore; Andrew Peitzman; George Velmahos; Frederick Alan Moore; Ari Leppaniemi; Clay Cothren Burlew; Walter L Biffl; Kaoru Koike; Yoram Kluger; Gustavo P Fraga; Carlos A Ordonez; Matteo Novello; Ferdinando Agresta; Boris Sakakushev; Igor Gerych; Imtiaz Wani; Michael D Kelly; Carlos Augusto Gomes; Mario Paulo Faro; Antonio Tarasconi; Zaza Demetrashvili; Jae Gil Lee; Nereo Vettoretto; Gianluca Guercioni; Roberto Persiani; Cristian Tranà; Yunfeng Cui; Kenneth Y Y Kok; Wagih M Ghnnam; Ashraf El-Sayed Abbas; Norio Sato; Sanjay Marwah; Muthukumaran Rangarajan; Offir Ben-Ishay; Abdul Rashid K Adesunkanmi; Helmut Alfredo Segovia Lohse; Jakub Kenig; Stefano Mandalà; Raul Coimbra; Aneel Bhangu; Nigel Suggett; Antonio Biondi; Nazario Portolani; Gianluca Baiocchi; Andrew W Kirkpatrick; Rodolfo Scibé; Michael Sugrue; Osvaldo Chiara; Fausto Catena
Journal:  World J Emerg Surg       Date:  2017-08-07       Impact factor: 5.469

View more
  4 in total

Review 1.  Prophylactic Mesh After Midline Laparotomy: Evidence is out There, but why do Surgeons Hesitate?

Authors:  Martijn Depuydt; Mathias Allaeys; Luis Abreu de Carvalho; Aude Vanlander; Frederik Berrevoet
Journal:  World J Surg       Date:  2021-02-08       Impact factor: 3.352

Review 2.  Ventral hernia repair with synthetic mesh in a contaminated field: a systematic review and meta-analysis.

Authors:  M P Morris; J A Mellia; A N Christopher; M N Basta; V Patel; K Qiu; R B Broach; J P Fischer
Journal:  Hernia       Date:  2021-01-19       Impact factor: 4.739

3.  Is absorbable mesh useful in preventing parastomal hernia after emergency surgery? The PARTHENOPE study.

Authors:  F Pizza; D D'Antonio; F S Lucido; P Del Rio; C Dell'Isola; L Brusciano; S Tolone; L Docimo; C Gambardella
Journal:  Hernia       Date:  2022-02-23       Impact factor: 4.739

Review 4.  Bioabsorbable mesh use in midline abdominal wall prophylaxis and repair achieving fascial closure: a cross-sectional review of stage of innovation.

Authors:  S K Kamarajah; N J Smart; I R Daniels; T D Pinkney; R L Harries
Journal:  Hernia       Date:  2020-05-24       Impact factor: 4.739

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.