Literature DB >> 31414154

[Upper Airway Stimulation for obstructive sleep apnea-Can radiological position monitoring predict tongue motion one year after implantation? German version].

A Steffen1, A S Wozny2, I R König3, J-P Goltz4, B Wollenberg2, K Hasselbacher2.   

Abstract

BACKGROUND: Tongue motion patterns (TMP) can influence the outcome of upper airway stimulation (UAS) in the treatment of obstructive sleep apnea (OSA). As a postoperative control the cuff position of the stimulation lead is monitored via X‑ray imaging. A multidimensional X‑ray assessment system was established and the association between these positional assessments and TMP was investigated 1 year after implantation.
MATERIAL AND METHODS: The study on TMP and the X‑ray assessments were carried out at a German ear nose and throat clinic as an implantation center. The TMPs were assessed under bipolar electrode configuration and were categorized according to the currently available literature as right-sided protrusion (RP), left-sided protrusion (LP), bilateral protrusion (BP) and mixed activation (MA). The X‑ray assessment was carried out in five dimensions: the position relative to the mandible and hyoid, cuff steepness in the lateral view of the neck, the cuff position based on the single electrode and the lead connection to the cuff in the anterior-posterior view. The analyses were performed by three raters with different medical backgrounds and knowledge regarding TMP.
RESULTS: In approximately 60% of the patients the apnea-hypopnea index was reduced to below 15/h, 1 year after implantation. The most common TMPs were RP and BP (82.9%). The interrater variability of the X‑ray assessment was good except for one category. Furthermore, no relevant associations were found apart from the correlation between a favorable TMP and the cuff position with respect to the lateral position of the stimulation cable.
CONCLUSION: Despite good interrater variability and convenient usage of the suggested X‑ray assessment system, this approach did not enable the identification of any associations, by which a TM and therefore a possible straightforward or complicated treatment pathway could be predicted. Attention should possibly be paid to a rotation of the cuff during implantation with a lateral position of the stimulation lead.

Entities:  

Keywords:  Hypoglossus nerve stimulation; Interrater variability; PAP failure; Rating system; Tongue protrusion

Mesh:

Year:  2019        PMID: 31414154     DOI: 10.1007/s00106-019-0715-6

Source DB:  PubMed          Journal:  HNO        ISSN: 0017-6192            Impact factor:   1.284


  14 in total

1.  Functional outcome of tongue motions with selective hypoglossal nerve stimulation in patients with obstructive sleep apnea.

Authors:  C Heiser; J T Maurer; A Steffen
Journal:  Sleep Breath       Date:  2015-08-28       Impact factor: 2.816

2.  Upper-airway stimulation for obstructive sleep apnea.

Authors:  Patrick J Strollo; Ryan J Soose; Joachim T Maurer; Nico de Vries; Jason Cornelius; Oleg Froymovich; Ronald D Hanson; Tapan A Padhya; David L Steward; M Boyd Gillespie; B Tucker Woodson; Paul H Van de Heyning; Mark G Goetting; Oliver M Vanderveken; Neil Feldman; Lennart Knaack; Kingman P Strohl
Journal:  N Engl J Med       Date:  2014-01-09       Impact factor: 91.245

3.  Nerve monitoring-guided selective hypoglossal nerve stimulation in obstructive sleep apnea patients.

Authors:  Clemens Heiser; Benedikt Hofauer; Luke Lozier; B Tucker Woodson; Thomas Stark
Journal:  Laryngoscope       Date:  2016-06-27       Impact factor: 3.325

Review 4.  Updates of operative techniques for upper airway stimulation.

Authors:  Clemens Heiser; Erica Thaler; Maurits Boon; Ryan J Soose; B Tucker Woodson
Journal:  Laryngoscope       Date:  2016-09       Impact factor: 3.325

5.  Surgical anatomy of the hypoglossal nerve: A new classification system for selective upper airway stimulation.

Authors:  Clemens Heiser; Andreas Knopf; Benedikt Hofauer
Journal:  Head Neck       Date:  2017-09-27       Impact factor: 3.147

6.  Effect of upper-airway stimulation for obstructive sleep apnoea on airway dimensions.

Authors:  Faiza Safiruddin; Olivier M Vanderveken; Nico de Vries; Joachim T Maurer; Kent Lee; Quan Ni; Kingman P Strohl
Journal:  Eur Respir J       Date:  2014-09-03       Impact factor: 16.671

7.  Tongue motion variability with changes of upper airway stimulation electrode configuration and effects on treatment outcomes.

Authors:  Armin Steffen; Ayse Kilic; Inke R König; Maria V Suurna; Benedikt Hofauer; Clemens Heiser
Journal:  Laryngoscope       Date:  2017-12-27       Impact factor: 3.325

8.  Palatoglossus coupling in selective upper airway stimulation.

Authors:  Clemens Heiser; Günther Edenharter; Murat Bas; Markus Wirth; Benedikt Hofauer
Journal:  Laryngoscope       Date:  2017-01-20       Impact factor: 3.325

9.  Outcomes of Upper Airway Stimulation for Obstructive Sleep Apnea in a Multicenter German Postmarket Study.

Authors:  Clemens Heiser; Joachim T Maurer; Benedikt Hofauer; J Ulrich Sommer; Annemarie Seitz; Armin Steffen
Journal:  Otolaryngol Head Neck Surg       Date:  2016-12-27       Impact factor: 3.497

10.  Outcome after one year of upper airway stimulation for obstructive sleep apnea in a multicenter German post-market study.

Authors:  Armin Steffen; J Ulrich Sommer; Benedikt Hofauer; Joachim T Maurer; Katrin Hasselbacher; Clemens Heiser
Journal:  Laryngoscope       Date:  2017-05-31       Impact factor: 3.325

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.