This study examined the effectiveness of a field-type liquid cooling vest (LCV) worn underneath an impermeable protective suit on heat strain during walking. Eight men walked for 60 min at a moderate speed (3.0 km/h) wearing the suit in a warm environment (33°C, 60% relative humidity) without (control, CON) or with the LCV. A smaller increase in rectal temperature was recorded in participants in the LCV than in the CON condition (37.6 ± 0.1°C vs. 37.9 ± 0.1°C, p<0.05). Walking while wearing the LCV reduced the level of physiological heat strain, as measured by the mean skin temperature (35.5 ± 0.1°C vs. 36.3 ± 0.1°C), chest sweat rate (13.5 ± 3.0 mg/cm2/h vs. 16.6 ± 3.8 mg/cm2/h), chest cutaneous vascular conductance (349 ± 88% vs. 463 ± 122%), body weight loss (0.72 ± 0.05% vs. 0.93 ± 0.06%), and heart rate (101 ± 6 beats/min vs. 111 ± 7 beats/min) (p<0.05, for all comparisons). These changes were accompanied by a decrease in thermal sensation and discomfort. These results suggest that a field-type LCV attenuates exertional heat strain while wearing impermeable protective clothing.
This study examined the effectiveness of a field-type liquid cooling vest (LCV) worn underneath an impermeable protective suit on heat strain during walking. Eight men walked for 60 min at a moderate speed (3.0 km/h) wearing the suit in a warm environment (33°C, 60% relative humidity) without (control, CON) or with the LCV. A smaller increase in rectal temperature was recorded in participants in the LCV than in the CON condition (37.6 ± 0.1°C vs. 37.9 ± 0.1°C, p<0.05). Walking while wearing the LCV reduced the level of physiological heat strain, as measured by the mean skin temperature (35.5 ± 0.1°C vs. 36.3 ± 0.1°C), chest sweat rate (13.5 ± 3.0 mg/cm2/h vs. 16.6 ± 3.8 mg/cm2/h), chest cutaneous vascular conductance (349 ± 88% vs. 463 ± 122%), body weight loss (0.72 ± 0.05% vs. 0.93 ± 0.06%), and heart rate (101 ± 6 beats/min vs. 111 ± 7 beats/min) (p<0.05, for all comparisons). These changes were accompanied by a decrease in thermal sensation and discomfort. These results suggest that a field-type LCV attenuates exertional heat strain while wearing impermeable protective clothing.
Workers who are exposed to hazards, such as biological, chemical or radiological agents,
must wear personal protective equipment. An increase in metabolic heat production during
work combined with high ambient temperature and humidity can lead to a progressive increase
in body heat content. Because restrictive clothing inhibits heat dissipation, prolonged work
while wearing personal protective equipment may lead to hyperthermia and heat illness.Some microclimate cooling systems have been found to inhibit the increase in heat strain in
workers wearing personal protective equipment1, 2). Cold or natural air ventilation, liquid
cooling and phase-change material garments each have a beneficial cooling effect. However,
microclimate cooling systems have inevitable ergonomic problems such as the additional
weight and layers, and restriction of body movement. Among these cooling systems, natural
air ventilation garments are lightweight and can be used for non-tethered cooling
systems3, 4), but providing complete protection from hazards while wearing
protective clothing remains a problem.In liquid cooling garments (LCGs), cool liquid is circuited inside tubes embedded in the
garment with the help of a battery-powered pump1). Once the liquid is warmed by the body, it is circulated to a
refrigeration control unit where it is recooled. Because early LCGs were developed for use
by astronauts in the hostile aerospace environment5), the weight of the control unit was not a concern. In one study, use
of a stationary cooling system, in which a pump delivered cool water from a regulated water
bath at 15°C to a whole-body garment, limited the increase in core temperature increased to
only 0.4°C during a 2-h exercise in participants wearing protective clothing; this
contrasted with a 2.0°C increase in participants wearing protective clothing without the
cooling system6). Although the optimal
design of an LCG was investigated in a theoretical model7), few studies have reported on the practical use of an LCG in a
non-tethered cooling system. Bartkowiak et al.8) reported on the effectiveness of an “active” LCG system
(tube-lined long sleeve underwear) used during walking in a warm condition while wearing
protective clothing. Although the LCG system was mobile, the weight of the cooling unit was
almost 10 kg, and the wearer had to carry around it when moving.Grahn et al.9) described
a “wearable” LCG system comprising a hydration backpack and tube-lined palmar pads. They
compared the effectiveness for reducing heat strain between the wearable LCG and an LCG with
a stationary cooling system while wearing protective clothing and found no difference.
Because further developments of cooling systems comprising a coolant, battery, and pump are
expected in the near future, it is important to determine the effectiveness of the latest
portable LCG for reducing heat strain.In the present study, we evaluated the effectiveness of a commercially available field-type
(non-tethered, wearable) LCG on heat strain in participants exercising while wearing
protective clothing. The LCG comprised a tube-lined water-perfusion vest and coolant
containing a backpack worn underneath protective clothing. We hypothesized that the use of
the LCG would reduce physiological and psychological heat strain during light exercise while
wearing protective clothing.
Subjects and Methods
Participants
Eight healthy men volunteered for the present study. The general characteristics of the
participants were: age, 36.0 ± 9.8 yr; height, 174.9 ± 5.0 cm; and body mass, 67.1 ±
5.9 kg (mean ± SD). All experimental procedures were approved by the Human Research Ethics
Committee of the National Institute of Occupational Safety and Health, Japan, in 2016. The
participants were informed of the experimental procedures and potential risks, and all
signed a consent form.
Microclimate cooling
The field-type LCG tested in this study was a commercially available vest (TSCB-17001,
Hitachi Power Solutions Co., Hitachi, Japan). The tube-lined water-perfusion vest was made
of 100% polyester and was laminated around small-diameter silicon tubing (1.6 mm, internal
diameter) divided into multiple parallel circuits. The total estimated tubing length for
the vest was 16 m and the total weight of the vest was 0.4 kg. The vest was connected to a
coolant-containing backpack, which measured 240 × 430 × 60 mm, and water was pumped via a
rechargeable battery at a rate of 300 ml/min. To recool the water in the backpack, a
silicon bag through which water was circulated was bookended between the ice packs. To
maintain the temperature of the ice packs and water, the inside of the backpack was
covered by thermal insulating materials. The outside of the backpack was made of polyester
and nylon to make it waterproof. The total weight of the backpack was 3.4 kg. The inlet
and outlet temperatures of the tubing were recorded using thermistor probes (LT-ST08-00,
Gram Corp., Saitama, Japan) that were attached to the external side of the tubing by tape
and wrapped by the materials of the vest. Although the temperature of the water was not
measured directly, we analyzed the energy uptake by the water using the inlet and outlet
temperatures of the tubing.
Experimental protocols
The study was performed in two climate chambers. One chamber was a thermoneutral room
with an ambient temperature of 25°C and 40% relative humidity (RH). The other was a heated
room with an ambient temperature of 33°C and 60% RH. In both rooms, the wind speed was 0.4
m/s.The volunteers performed two experimental trials: one wearing the LCV (LCV trial) and the
other a control trial without the LCV (CON). These two tests were repeated at a 1-wk
interval in a balanced order. The volunteers refrained from consuming any beverages
containing caffeine or alcohol from the night before the day of the experiment. They ate a
light meal 3 h before the experiment and then reported to the laboratory. After drinking
200 ml of water and voiding completely, each volunteer entered the thermoneutral room
wearing a T-shirt (100% polyester, 160 g) and shorts (100% polyester, 64 g). No water was
provided until the end of the experiment. After a 30-min first acclimation period,
physiological sensors and probes were attached, and baseline measurements were obtained
with the participant in a seated position. After the 30-min baseline period, in both the
CON and LCV trials the volunteer put on a round-neck T-shirt with long sleeves (100%
polyester, 174 g), long underwear (100% polyester, 226 g), cotton gloves (100% cotton,
18 g), rubber gloves (100% natural rubber, 37 g), socks (100% cotton, 58 g), work shoes
(1,030 g), high-density polyethylene coveralls (Tyvek®, DuPont, Wilmington, DE,
USA; 160 g), a full-face gas mask (354 g) and a helmet (426 g). Fifteen minutes later, in
the LCV trial, the participant put on the vest and backpack over the long sleeve shirt,
and the cooling system was started. To confirm that the system was working properly, the
participant continued to rest for 10 min, after which he moved to the heated room and
remained seated for another 5 min. After rating his perception, each participant walked on
a treadmill (SportsArt Fitness T650, Woodinville, WA, USA) for 30 min at 3 km/h. Following
a 10-min break, the participant walked again for 30 min. During the break, the volunteer
remained seated in the heated room.
Measurements
Rectal temperature (Trec) was measured continuously using a thermistor probe
(701 J, Nikkiso-Therm, Tokyo, Japan) self-inserted by the participant to 12 cm beyond the
rectal sphincter. Skin temperature (Tskin) was also monitored continuously
using thermistor probes (010, Nikkiso-Therm) placed on the forehead, back, chest, forearm,
dorsal side of the hand, thigh, calf and dorsal side of the foot. These temperature data
were recorded using LT loggers (LT-8, Gram Corp.) at 1-min intervals. The mean
Tskin was calculated using the following equation and the temperatures of the
regional areas [0.07 Tskin on forehead + 0.35 (Tskin on chest +
Tskin on back)/2 + 0.14 Tskin on forearm + 0.05 Tskin
on dorsal hand + 0.19 Tskin on thigh + 0.13 Tskin on calf + 0.07
Tskin on dorsal foot]10).
The rate of body heat storage (W) was calculated as the change in body heat content per
time. The body heat content was calculated as the average body temperature (in°C) × body
mass (in kg) × 3.47 (mean specific heat capacity of the body, in kj·°C−1·kg
−1)11). Average body
temperature was determined using thermometry (with weightings of 0.9 Trec and
0.1 mean Tskin)11).Blood pressure (right brachial artery) and heart rate (three-lead electrocardiogram) were
measured and recorded using a Tango exercise blood pressure monitor (SunTech, Morrisville,
NC, USA). Sweat rate on the chest was monitored by dew point hygrometry (OKS-04HM, Skiken,
Nagoya, Japan). Blood flow in the chest skin was estimated using laser Doppler flowmetry
(LDF; FLO-C1, Omegawave, Tokyo, Japan). To connecting the cables to each device
(sphygmomanometer, electrocardiograph, dew point hygrometer, and laser Doppler flowmeter),
the cables were put through a hole around the waist, and the hole was closed by tape. The
LDF data are expressed as the percentage change from the averaged value of the baseline
period. Cutaneous vascular conductance (CVC) was calculated as the LDF value divided by
the mean arterial pressure and is expressed as the percentage change from the baseline
value. Body weight was measured before and after the experiment with the participant
wearing only undershorts.Thermal sensation and comfort, and physical and psychological fatigue were assessed using
a visual analog scale. In the ratings of thermal sensation and comfort, we used a 200 mm
visual analog scale, where ‘coldest’ or ‘most uncomfortable’ was indicated on the extreme
left and scored as −10, ‘hottest’ or ‘most comfortable’ was indicated on the extreme right
and scored as 10, and ‘neutral’ indicated on the center and scored as 012, 13). The length from 0 point was determined as the rating value. The
volunteers were instructed to separate carefully the thermal sensation from comfort by
asking them to report their current thermal perception; that is, how much they felt the
ambient temperature had increased or decreased and how much they liked or disliked the
thermal condition, respectively. We also asked them to separate their thermal perceptions
for ‘the whole body’ and ‘torso’. Although it is debated whether a categorical (numerical)
scale, the visual analog scale, or both combined is more valid for the assessment of
subjective thermal sensation14, 15), we selected the visual analog scale to
assess possible regional differences (whole body versus torso) for each thermal sensation
and comfort. For evaluating fatigue, we used a 100 mm visual analog scale, where the
minimal rating was scored as 0 (indicated ‘not fatigued at all’) and the maximal rating as
10 (indicated ‘extremely fatigued’).
Statistics
Two-way analysis of variance (ANOVA) with repeated measures (using trial and time as the
main effects) was performed. If a significant F-value was observed, Bonferroni’s least
significant difference post hoc test was performed to identify the difference at a
specific time point. The null hypothesis was rejected at p<0.05. All
analyses were performed using StatView 5.0 software (SAS Institute, Cary, NC, USA). Values
are expressed as means ± SEM.
Results
Physiological strain
Trec increased significantly during walking in both the CON and LCV trials
(Fig. 1 (a), p<0.05), but Trec from 5 min after the beginning of
walking to the end of walking was lower in the LCV than in the CON
(p<0.05). Mean Tskin was also lower in the LCV trial than
in the CON trial immediately after wearing the LCV (Fig. 1 (b), p<0.05). Tskin values on the back and
chest were lower in the LCV than in the CON trial (Fig.
1 (c) and (d), p<0.05). Tskin on the back
decreased significantly immediately after wearing the LCV (Fig. 1 (c), p<0.05) and remained below the
baseline, whereas the Tskin increased during walking in the CON trial
(p<0.05). The increase in Tskin on the chest was delayed
in the LCV compared with the CON trial (Fig. 1
(d)). The mean heat storage rates were greater in the CON than in the LCV trial
(30 ± 2 W vs. 21 ± 2 W, p<0.05). Increases in heart rate and sweat
rate were lower in the latter half of walking in the LCV than in the CON trial (Fig. 2 (a) and (b), p<0.05). Blood pressure did not change in the two trials (data
not shown). The increase in%CVC was smaller throughout the walking in the LCV than in the
CON trial (Fig. 2 (c),
p<0.05). The percentage reduction in body weight after walking was
greater in the CON than in the LCV trial (0.93 ± 0.06% vs. 0.72 ± 0.05%,
p<0.05).
Fig. 1.
Rectal temperature (a), and mean (b), back (c), and chest (d) skin temperatures in
the non-cooling control (CON) and liquid cooling vest (LCV) trials. *Different
(<0.05) between CON and LCV. Values are mean ±
SEM (=8).
Fig. 2.
Heart rate (a), sweat rate (b), laser Doppler flow (c) and cutaneous vascular
conductance (d) on the chest in the non-cooling control (CON) and liquid cooling
vest (LCV) trials.
*Different (p<0.05) between CON and LCV. Values are mean ± SEM
(n=8).
Rectal temperature (a), and mean (b), back (c), and chest (d) skin temperatures in
the non-cooling control (CON) and liquid cooling vest (LCV) trials. *Different
(<0.05) between CON and LCV. Values are mean ±
SEM (=8).Heart rate (a), sweat rate (b), laser Doppler flow (c) and cutaneous vascular
conductance (d) on the chest in the non-cooling control (CON) and liquid cooling
vest (LCV) trials.*Different (p<0.05) between CON and LCV. Values are mean ± SEM
(n=8).
Psychological strain
Thermal sensation of the whole body increased during walking in both the CON and LCV
trials (Fig. 3 (a), p<0.05), but the increases were smaller in the LCV than in the
CON trial throughout the walking exercise (p<0.05). In parallel,
thermal comfort of the whole body decreased during walking in both the CON and LCV trials
(Fig. 3 (b), p<0.05), but
the decreases were smaller in the LCV than in the CON trial throughout the walking
exercise (p<0.05). Thermal sensation of the torso increased
immediately after the walking exercise in the CON trial (Fig. 3 (c), p<0.05) but decreased immediately
before and after the walking exercise in the LCV trial (p<0.05) and
remained at the baseline level during walking. Thermal sensation of the torso was lower in
the LCV than in the CON trial (p<0.05). Thermal comfort of the torso
decreased from 15 min after the beginning of walking in the CON trial (Fig. 3 (d), p<0.05) but
increased immediately before and after the walking exercise in the LCV trial
(p<0.05). Thermal comfort was greater in the LCV than in the CON
trial (p<0.05). Physical and psychological fatigue increased from
20 min after the beginning of walking in both the CON and LCV trials (Fig. 3 (e) and (f), p<0.05), but the ratings
did not differ between trials.
Fig. 3.
Rating scores of thermal sensation of the whole body (a), thermal comfort of the
whole body (b), thermal sensation of the torso (c), thermal comfort of the torso
(d), physical fatigue (e) and psychological fatigue (f) in the non-cooling control
(CON) and liquid cooling vest (LCV) trials.
*Different (p<0.05) between CON and LCV. Values are mean ± SEM
(n=8).
Rating scores of thermal sensation of the whole body (a), thermal comfort of the
whole body (b), thermal sensation of the torso (c), thermal comfort of the torso
(d), physical fatigue (e) and psychological fatigue (f) in the non-cooling control
(CON) and liquid cooling vest (LCV) trials.*Different (p<0.05) between CON and LCV. Values are mean ± SEM
(n=8).
Tubing temperatures and energy uptake by water
Figure 4 shows the inlet (to the vest) and outlet temperatures of the tubing and energy
uptake by water in the LCV. Although both temperatures were stable in the thermoneutral
room, moving into the heated room caused an increase in both temperatures. The differences
between the inlet and outlet temperatures remained constant throughout the walking
exercise (2.6 ± 0.1°C). The energy uptake by water did not change significantly throughout
the experiment, but the values tended to be greater in the resting condition than during
walking.
Fig. 4.
Tube temperatures in the outlet and inlet to the vest and energy uptake by the
water in the liquid cooling vest (LCV) trial.
Values are mean ± SEM (n=8).
Tube temperatures in the outlet and inlet to the vest and energy uptake by the
water in the liquid cooling vest (LCV) trial.Values are mean ± SEM (n=8).
Discussion
We compared heat strain during walking while wearing protective clothing between wearing
and not wearing an LCV and found that wearing the LCV reduced the physiological and
psychological heat strain during two 30-min walking periods. Although the field-type cooling
system was carried on the participant’s back, their perception of fatigue did not increase
compared with the CON trial.In the study by Caldwell et al.6), a stationary cooling system to deliver water at a constant 15°C by
a pump to a whole-body LCG maintained core temperature, Tskin and heart rate at
low levels during light exercise while wearing protective clothing compared with the
no-cooling condition. Although the environmental conditions (33°C with 60% RH vs. 48°C with
20% RH) and exercise modes (walking vs. cycling) differed between our study and that by
Caldwell et al.6), it is
useful to compare the cooling efficiency of the non-tethered and tethered systems. For core
temperature, the earlier study6) reported
38.0°C at 60 min in the control and 37.3°C in the LCG condition (baseline: 36.9°C), giving a
cooling effectiveness of 65% (the extent of the reduction). In the present study, the
cooling effectiveness for Trec was 28% (baseline, 37.0°C; CON, 37.9°C; LCV,
37.6°C at 70 min). Similarly, the cooling effectiveness for other parameters was lower in
the present study than in the study by Caldwell et al.6): mean Tskin, 28% vs. 65%; heart rate, 23% vs.
57%; and body weight reduction, 22% vs. 80%, respectively.Although the inlet tube temperature was 15°C in the thermoneutral room in the present
study, the temperature increased to 25°C at the end of walking (Fig. 4). The differences in the water temperature and covered body
area (torso vs. whole body) may have caused the loss of cooling efficiency. By contrast,
Grahn et al.9)
demonstrated that palm cooling by a wearable LCG reduced the rate for increase in esophageal
temperature by 47% during light-intensity walking while wearing protective clothing.
Although the surface area of the palms is small, this region has unique radiator-like
vascular structures underlying the glabrous skin16). The cooling effectiveness for core temperature was greater in the
study by Grahn et al.9)
than in our study. The vest does not restrict body movement, unlike palmar pads and arm tube
lines, and workers may select the most suitable LCG depending on their work situation.The Tskin values on the back and chest were lowered in the LCV than in the CON
trial throughout the walking exercise (Fig. 1 (c) and
(d)), whereas the inlet tube temperature increased progressively. This torso
cooling made the participants feel cold and more comfortable on their torso immediately
before and after the walking exercise (Fig. 3 (c) and
(d)). During the next walking period, the participants did not feel hot or
uncomfortable on the torso in the LCV trial. By contrast, the thermal sensation of the whole
body increased and the thermal comfort of the whole body decreased throughout the walking
period (>Fig.
3 (a) and (b)), whereas the participants felt ‘less hot’ and ‘less
uncomfortable’ in the LCV trial than those in the CON trial. Because thermal sensation is
conveyed by the warm and cold receptors in the skin and thermal comfort is affected by
information from the skin and core temperatures17), attenuating increases in mean Tskin and Trec
during walking in the LCV trial may have modulated the thermal perceptions.The increases in physical and psychological fatigue were similar in the CON and LCV trials
(Fig. 3 (e) and (f)). Because the burden of
wearing the LCV might increase fatigue, these findings should be considered when using such
a device in practice. However, it is possible that reliefs of the physiological strain and
thermal perception attenuated the increased feeling of fatigue; that is, the weight of the
LCV could have offset the reliefs. Although wearing the LCV did not appear to cause any
negative effects in the present study, the mobility and ergonomic aspects should be assessed
in future experiments in which participants wear the LCV with its cooling function turned
off and perform agility tests.In practice, workers who move around large working areas must use field-type microclimate
cooling systems. Phase-change materials (e.g., ice packs) are also used to make garments
with conductive cooling such as LCGs. A study by Muir et al.18) placed frozen gel packs into the outside
pockets of protective clothing with fitting straps that were secured close to wearer’s body
(weight: 5.2 kg). During walking at 28°C wet bulb globe temperature (34°C dry bulb
temperature), the cooling effectiveness for core temperature and heart rate in participants
wearing this ice-cooling system was 36% and 8% at 60 min, respectively. In Kenny et
al.19), the wearing of an
ice-cooling vest (weight: 4.1 kg) underneath protective clothing during walking at 35°C with
65% RH reduced physiological and psychological strain. The cooling effectiveness at 60 min
was 22% for core temperature and 17% for heart rate; thermal sensation and perceived
exertion were also reduced by the cooling vest.Ambient air ventilation systems (e.g., convective cooling) have been shown reduce heat
strain effectively3, 4). Chinevere et al.3) studied the effect of a ventilation system to cool the torso
(weight: up to 2.3 kg) worn underneath an army combat uniform during a 60-min walk at 35°C
with 75% RH. The cooling effectiveness was 13% for core temperature and 18% for heart rate
compared with the same condition with participants not wearing the system. In a similar
study, using a ventilation system to cool the torso (weight: up to 1.2 kg) worn underneath a
battle dress uniform, Hadid et al.4) found evidence of reduced physiological strain during a 120-min walk
at 35°C with 60% RH; the cooling effectiveness was 30% for core temperature, 19% for heart
rate, and 25% for sweat rate. These two ventilation cooling studies analyzed body heat
storage rates, and the cooling effectiveness was 21%3) and 25%4). In the
present study, the cooling effectiveness for body heat storage was 29%, which was similar to
that for core temperature.Song and Wang20) applied a combined
cooling system and ventilation system with phase-change materials (weight: up to 3.6 kg) to
both the upper and lower body worn with a standard work uniform. The cooling effectiveness
for non-ventilation and phase-change materials was 40% for core temperature and 38% for
heart rate during a 70-min walk at 36°C with 59% RH. Although it remains unclear how
combined systems affect cooling efficiency, it is reasonable to assume that applying an LCG
system to the lower body would increase cooling effectiveness.The efficiencies in reducing heat strain measured in our study are similar to those
measured in previous studies, despite the differences in weight, form, and energy supply.
Our findings suggest that workers may be able to select suitable cooling systems appropriate
to their workplace and conditions. The LCGs and ventilation cooling should be used with a
battery. Although the working time may be dependent on the battery’s duration, workers can
switch on and off the cooling system at any given time as the situation demands. However,
when a worker is wearing protective clothing to provide strong protection against specific
hazards, the ventilation cooling system may experience some problems such as contaminant
input.The difference in heat storage between the CON and LCV trials was 9 W, whereas the cooling
power of the LCV by calculating the energy uptake in circulating water was 55 W. The heat
loss (46 W) indicates difficulty in cooling efficiency using LCGs. The energy uptake by
water includes heat loss into outside environment. It contains also inside environment
(between the LCV and skin), because Tskin responses in the LCV trial differed
between the back and chest (Fig. 1 (c) and (d)).
Improvements of the materials of the vest are needed to inhibit heat loss and fit the
torso’s surface.A potential limitation to the present study was that metabolic rate was not measured during
walking. The LCG burdens the wearer, and we plan a future study to measure the additional
energy expenditure. Second, the exercise and heat exertion were at low levels. Further study
is needs to determine whether the LCV is also effective during more intense exertion and
hyperthermic conditions. Third, a potential limitation relates to whether the participants
should undergo a heat acclimation period before the experiments. Although we could not
measure the participants’ fitness level, they were basically sedentary and were not
regularly exposed to a hot work environment. Heat and exercise acclimation may allow the
participant to perform more severe exertion. A fourth limitation of our study is that our
participants performed exercise of only one duration while wearing the LCV, and future
studies should include exercise of different durations. Because ISO 1289421) and the American Conference of
Governmental Industrial Hygienists (ACGIH)22) define the core temperature threshold of 38.0°C, we should have
examined how long it took for core temperature to reach this threshold in the LCV trial.
Conclusion
In the present study, we compared the physiological and psychological heat strain between
exercise in participants wearing or not wearing a field-type LCV while wearing an
impermeable protective suit. The increases in rectal and mean skin temperatures, heart rate,
heat storage, sweat rate, and cutaneous vascular conductance on the chest during 1 h of
walking were significantly lower with than without the LCV. The rating scores of thermal
sensation and discomfort for the whole body were also significantly lower with than without
the LCV. Increases in these perceptions of torso without the LCV disappeared in with the
LCV. Although the LCV system was a burden on the wearer, the rating scores of fatigue during
walking did not differ significantly between exercise with and without the LCV. Because the
effectiveness of reducing heat strain was reasonable compared with other microclimate
cooling systems, workers wearing protective clothing may be able to select the most suitable
cooling system according to their work condition.
Authors: Glen P Kenny; Andrew R Schissler; Jill Stapleton; Matthew Piamonte; Konrad Binder; Aaron Lynn; Christopher Q Lan; Stephen G Hardcastle Journal: J Occup Environ Hyg Date: 2011-08 Impact factor: 2.155
Authors: Nigel A S Taylor; Christiano A Machado-Moreira; Anne M J van den Heuvel; Joanne N Caldwell Journal: Eur J Appl Physiol Date: 2014-07-11 Impact factor: 3.078
Authors: Margaret C Morrissey; Douglas J Casa; Gabrielle J Brewer; William M Adams; Yuri Hosokawa; Courteney L Benjamin; Andrew J Grundstein; David Hostler; Brendon P McDermott; Meredith L McQuerry; Rebecca L Stearns; Erica M Filep; David W DeGroot; Juley Fulcher; Andreas D Flouris; Robert A Huggins; Brenda L Jacklitsch; John F Jardine; Rebecca M Lopez; Ronda B McCarthy; Yannis Pitisladis; Riana R Pryor; Zachary J Schlader; Caroline J Smith; Denise L Smith; June T Spector; Jennifer K Vanos; W Jon Williams; Nicole T Vargas; Susan W Yeargin Journal: Geohealth Date: 2021-08-01