Literature DB >> 31401853

Feasibility, Safety, and Efficacy of Posterior Wall Isolation During Atrial Fibrillation Ablation: A Systematic Review and Meta-Analysis.

Anand Thiyagarajah1,2, Kadhim Kadhim1,2, Dennis H Lau1,2, Mehrdad Emami1,2, Dominik Linz1,2, Kashif Khokhar1,2, Dian A Munawar1,2, Ricardo Mishima1,3, Varun Malik1,2, Catherine O'Shea1,2, Rajiv Mahajan1,2, Prashanthan Sanders1,2.   

Abstract

BACKGROUND: The posterior left atrium is an arrhythmogenic substrate that contributes to the initiation and maintenance of atrial fibrillation (AF); however, the feasibility, safety, and efficacy of posterior wall isolation (PWI) as an AF ablation strategy has not been widely reported.
METHODS: We undertook a systematic review and meta-analysis of studies performing PWI to assess (1) acute procedural success including the ability to achieve PWI and the number of procedure-related complications, (2) Long-term, clinical success including rates of arrhythmia recurrence and posterior wall reconnection, and (3) The efficacy of PWI compared with pulmonary vein isolation on preventing arrhythmia recurrence. MEDLINE, EMBASE, and Web of Science databases were searched in May 2018 to retrieve relevant studies. Results were pooled using a random effects model.
RESULTS: Seventeen studies (13 box isolation, 3 single ring isolation, and 1 debulking ablation) comprising 1643 patients (31.3% paroxysmal AF, left atrial diameter 41±3.1 mm) were included in the final analysis. In studies focusing specifically on PWI, the acute procedural success rate for achieving PWI was 94.1% (95% CI, 87.2%-99.3%). Single-procedure 12-month freedom from atrial arrhythmia was 65.3% (95% CI, 57.7%-73.9%) overall and 61.9% (54.2%-70.8%) for persistent AF. Randomized control trials comparing PWI to pulmonary vein isolation (3 studies, 444 patients) yielded conflicting results and could not confirm an incremental benefit to PWI. Fifteen major complications (0.1%), including 2 atrio-esophageal fistulas, were reported.
CONCLUSIONS: PWI as an end point of AF ablation can be achieved in a large proportion of cases with good rates of 12-month freedom from atrial arrhythmia. Although the procedure-related complication rate is low, it did not eliminate the risk of atrio-esophageal fistula. Registration: URL: http://www.crd.york.ac.uk/prospero. PROSPERO registration number: CRD42018107212.

Entities:  

Keywords:  atrial fibrillation; catheter ablation; esophageal fistula; meta-analysis; posterior left atrium; pulmonary vein

Mesh:

Year:  2019        PMID: 31401853     DOI: 10.1161/CIRCEP.118.007005

Source DB:  PubMed          Journal:  Circ Arrhythm Electrophysiol        ISSN: 1941-3084


  20 in total

Review 1.  Comparing the efficacy of catheter ablation strategies for persistent atrial fibrillation: a Bayesian analysis of randomized controlled trials.

Authors:  Sijia Wu; Hongkai Li; Shaolei Yi; Jianming Yao; Xueming Chen
Journal:  J Interv Card Electrophysiol       Date:  2022-07-04       Impact factor: 1.900

2.  Comparison of cryoballoon and radiofrequency ablation for persistent atrial fibrillation: a systematic review and meta-analysis.

Authors:  Jitae A Kim; Mihail G Chelu
Journal:  J Interv Card Electrophysiol       Date:  2022-09-12       Impact factor: 1.759

3.  Optimal Catheter Ablation Strategy for Patients with Persistent Atrial Fibrillation and Heart Failure: A Retrospective Study.

Authors:  Cheng-Ming Ma; Ye-Jian He; Wen-Wen Li; Hua-Min Tang; Shi-Yu Dai; Xiao-Meng Yin; Xian-Jie Xiao; Yun-Long Xia; Lian-Jun Gao; Yuan-Jun Sun; Zhong-Zhen Wang; Rong-Feng Zhang
Journal:  Cardiol Res Pract       Date:  2022-06-23       Impact factor: 1.990

Review 4.  A Chronicle of Hybrid Atrial Fibrillation Ablation Therapy: From Cox Maze to Convergent.

Authors:  Riyaz A Kaba; Omar Ahmed; Elijah Behr; Aziz Momin
Journal:  Arrhythm Electrophysiol Rev       Date:  2022-04

5.  The efficacy of posterior wall isolation in atrial fibrillation ablation: A systematic review and meta-analysis of randomized controlled trials.

Authors:  Chanavuth Kanitsoraphan; Pattara Rattanawong; Chol Techorueangwiwat; Jakrin Kewcharoen; Raktham Mekritthikrai; Narut Prasitlumkum; Parthav Shah; Hicham El Masry
Journal:  J Arrhythm       Date:  2022-03-17

Review 6.  Catheter ablation for atrial fibrillation: current indications and evolving technologies.

Authors:  Ramanathan Parameswaran; Ahmed M Al-Kaisey; Jonathan M Kalman
Journal:  Nat Rev Cardiol       Date:  2020-10-13       Impact factor: 32.419

7.  Contact-Force Guided Posterior Wall Isolation as an Adjunctive Ablation Strategy for Persistent Atrial Fibrillation.

Authors:  Giusy Sirico; Domenico Sirico; Andrea Montisci; Enrico Cerrato; Martina Morosato; Stefania Panigada; Luca Ottaviano; Valerio De Sanctis; Massimo Mantica
Journal:  J Atr Fibrillation       Date:  2021-08-31

8.  Single ring isolation for atrial fibrillation ablation: How to do it and avoid the esophagus.

Authors:  Rajiv Mahajan; Anand Thiyagarajah; Dennis H Lau; Prashanthan Sanders
Journal:  HeartRhythm Case Rep       Date:  2020-04-15

9.  Safety and Efficacy of High Power Shorter Duration Ablation Guided by Ablation Index or Lesion Size Index in Atrial Fibrillation Ablation: A Systematic Review and Meta-Analysis.

Authors:  Xing Liu; Chun Gui; Weiming Wen; Yan He; Weiran Dai; Guoqiang Zhong
Journal:  J Interv Cardiol       Date:  2021-06-02       Impact factor: 2.279

10.  Ablation Therapy for Persistent Atrial Fibrillation.

Authors:  Ikechukwu Ifedili; Kristina Mouksian; David Jones; Ibrahim El Masri; Mark Heckle; John Jefferies; Yehoshua C Levine
Journal:  Curr Cardiol Rev       Date:  2022
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.