Literature DB >> 34950369

Contact-Force Guided Posterior Wall Isolation as an Adjunctive Ablation Strategy for Persistent Atrial Fibrillation.

Giusy Sirico1, Domenico Sirico2, Andrea Montisci3,3, Enrico Cerrato4, Martina Morosato1, Stefania Panigada1, Luca Ottaviano1, Valerio De Sanctis1, Massimo Mantica1.   

Abstract

BACKGROUND: The efficacy of posterior wall isolation (PWI) on top of pulmonary vein isolation (PVI) in patients affected by persistent atrial fibrillation (AF) is still controversial and little is known about the impact of contact-force (CF) technology.
OBJECTIVE: In this retrospective study, we present our experience with PWI using CF sensing catheters and its efficacy and safety as an adjunctive ablation strategy on top of PVI for management of patients with persistent and longstanding persistent AF.
METHODS: A total of 73 consecutive patients (20.5% female) affected by persistent atrial fibrillation (10.9% long-standing) underwent PWI as an adjunctive therapy to PVI using CF sensing catheters. Outcomes were reported as incidence of atrial arrhythmic recurrences (ARs) lasting >30 seconds at follow up and in addition, in patients provided with insertable cardiac monitors (ICM), as burden of AF or atrial tachycardias (AT) at relevant time points.
RESULTS: PWI was successfully achieved in 65 (89.0%) patients. Two (2.7%) minor vascular procedural complications were observed. At 1 and 2-year follow-up, ARs free survival was observed in 80.5% and 64.1% of patients, respectively with 75.3% of patients off antiarrhythmic drugs at the last follow-up. Ten patients underwent repeat ablations during the follow-up. At multivariate analysis, early ARs within 3 months after procedure, were associated with a two-fold increased risk of late ARs at follow-up. Among patients provided with ICM, PWI on top of PVI was able to reduce the mean AT/AF burden of more than 50% compared with pre-ablation time, reporting very low levels (≤ 5%) over 2 years.
CONCLUSIONS: In persistent atrial fibrillation, PWI on top of PVI using CF sensing catheters is safe and effective, providing great reduction of burden of ARs. Early ARs are associated with a greater risk of late recurrences.

Entities:  

Keywords:  AF Burden; Contact Force; Early Recurrence; Persistent Atrial Fibrillation; Posterior Wall Isolation

Year:  2021        PMID: 34950369      PMCID: PMC8691276          DOI: 10.4022/jafib.20200475

Source DB:  PubMed          Journal:  J Atr Fibrillation        ISSN: 1941-6911


  25 in total

1.  Proven isolation of the pulmonary vein antrum with or without left atrial posterior wall isolation in patients with persistent atrial fibrillation.

Authors:  Rong Bai; Luigi Di Biase; Prasant Mohanty; Chintan Trivedi; Antonio Dello Russo; Sakis Themistoclakis; Michela Casella; Pietro Santarelli; Gaetano Fassini; Pasquale Santangeli; Sanghamitra Mohanty; Antonio Rossillo; Gemma Pelargonio; Rodney Horton; Javier Sanchez; Joseph Gallinghouse; J David Burkhardt; Chang-Sheng Ma; Claudio Tondo; Andrea Natale
Journal:  Heart Rhythm       Date:  2015-08-13       Impact factor: 6.343

2.  The surgical treatment of atrial fibrillation. III. Development of a definitive surgical procedure.

Authors:  J L Cox; R B Schuessler; H J D'Agostino; C M Stone; B C Chang; M E Cain; P B Corr; J P Boineau
Journal:  J Thorac Cardiovasc Surg       Date:  1991-04       Impact factor: 5.209

3.  Recurrence of Atrial Fibrillation After Catheter Ablation or Antiarrhythmic Drug Therapy in the CABANA Trial.

Authors:  Jeanne E Poole; Tristram D Bahnson; Kristi H Monahan; George Johnson; Hoss Rostami; Adam P Silverstein; Hussein R Al-Khalidi; Yves Rosenberg; Daniel B Mark; Kerry L Lee; Douglas L Packer
Journal:  J Am Coll Cardiol       Date:  2020-06-30       Impact factor: 24.094

4.  Randomized, Controlled Trial of the Safety and Effectiveness of a Contact Force-Sensing Irrigated Catheter for Ablation of Paroxysmal Atrial Fibrillation: Results of the TactiCath Contact Force Ablation Catheter Study for Atrial Fibrillation (TOCCASTAR) Study.

Authors:  Vivek Y Reddy; Srinivas R Dukkipati; Petr Neuzil; Andrea Natale; Jean-Paul Albenque; Josef Kautzner; Dipen Shah; Gregory Michaud; Marcus Wharton; David Harari; Srijoy Mahapatra; Hendrik Lambert; Moussa Mansour
Journal:  Circulation       Date:  2015-08-10       Impact factor: 29.690

5.  The Electrical Isolation of the Left Atrial Posterior Wall in Catheter Ablation of Persistent Atrial Fibrillation.

Authors:  Jung Myung Lee; Jaemin Shim; Junbeom Park; Hee Tae Yu; Tae-Hoon Kim; Jin-Kyu Park; Jae-Sun Uhm; Jin-Bae Kim; Boyoung Joung; Moon-Hyoung Lee; Young-Hoon Kim; Hui-Nam Pak
Journal:  JACC Clin Electrophysiol       Date:  2019-10-30

6.  One-year outcomes after pulmonary vein isolation plus posterior wall isolation and additional non-pulmonary vein trigger ablation for persistent atrial fibrillation with or without contact force sensing: a propensity score-matched comparison.

Authors:  Tomomasa Takamiya; Junichi Nitta; Osamu Inaba; Akira Sato; Takashi Ikenouchi; Kazuya Murata; Yukihiro Inamura; Yoshihide Takahashi; Masahiko Goya; Kenzo Hirao
Journal:  J Interv Card Electrophysiol       Date:  2020-01-06       Impact factor: 1.900

7.  Early recurrence of atrial fibrillation after pulmonary vein isolation: a comparative analysis between cryogenic and contact force radiofrequency ablation.

Authors:  Aditi S Vaishnav; Evan Levine; Kristie M Coleman; Stuart J Beldner; Jason S Chinitz; Kabir Bhasin; Neil E Bernstein; Nicholas T Skipitaris; Stavros E Mountantonakis
Journal:  J Interv Card Electrophysiol       Date:  2019-10-25       Impact factor: 1.900

Review 8.  Efficacy and safety of ablation for people with non-paroxysmal atrial fibrillation.

Authors:  Jonathan Nyong; Guy Amit; Alma J Adler; Onikepe O Owolabi; Pablo Perel; David Prieto-Merino; Pier Lambiase; Juan Pablo Casas; Carlos A Morillo
Journal:  Cochrane Database Syst Rev       Date:  2016-11-22

9.  EFFICAS II: optimization of catheter contact force improves outcome of pulmonary vein isolation for paroxysmal atrial fibrillation.

Authors:  Josef Kautzner; Petr Neuzil; Hendrik Lambert; Petr Peichl; Jan Petru; Robert Cihak; Jan Skoda; Dan Wichterle; Erik Wissner; Aude Yulzari; Karl-Heinz Kuck
Journal:  Europace       Date:  2015-06-03       Impact factor: 5.214

10.  Continuous monitoring after atrial fibrillation ablation: the LINQ AF study.

Authors:  Simon Wechselberger; Mads Kronborg; Yan Huo; Judith Piorkowski; Sebastian Neudeck; Ellen Päßler; Ali El-Armouche; Utz Richter; Julia Mayer; Stefan Ulbrich; Liying Pu; Bettina Kirstein; Thomas Gaspar; Christopher Piorkowski
Journal:  Europace       Date:  2018-11-01       Impact factor: 5.214

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.