Literature DB >> 31394926

Simultaneous measurements of indoor radon and thoron and inhalation dose assessment in Douala City, Cameroon.

Takoukam Soh Serge Didier1,2, Shinji Tokonami3, Masahiro Hosoda4, Takahito Suzuki4, Hiromi Kudo4, Oumarou Bouba1.   

Abstract

Radon, thoron and associated progeny measurements have been carried out in 71 dwellings of Douala city, Cameroon. The radon-thoron discriminative detectors (RADUET) were used to estimate the radon and thoron concentration, while thoron progeny monitors measured equilibrium equivalent thoron concentration (EETC). Radon, thoron and thoron progeny concentrations vary from 31 ± 1 to 436 ± 12 Bq m-3, 4 ± 7 to 246 ± 5 Bq m-3, and 1.5 ± 0.9 to 13.1 ± 9.4 Bq m-3. The mean value of the equilibrium factor for thoron is estimated at 0.11 ± 0.16. The annual effective dose due to exposure to indoor radon and progeny ranges from 0.6 to 9 mSv a-1 with an average value of 2.6 ± 0.1 mSv a-1. The effective dose due to the exposure to thoron and progeny vary from 0.3 to 2.9 mSv a-1 with an average value of 1.0 ± 0.4 mSv a-1. The contribution of thoron and its progeny to the total inhalation dose ranges from 7 to 60 % with an average value of 26 %; thus their contributions should not be neglected in the inhalation dose assessment.

Entities:  

Keywords:  Equilibrium factor; Rn–Tn discriminative detector; inhalation dose; ionogenic radiation exposure; radio ecology; radon; thoron

Mesh:

Substances:

Year:  2019        PMID: 31394926     DOI: 10.1080/10256016.2019.1649258

Source DB:  PubMed          Journal:  Isotopes Environ Health Stud        ISSN: 1025-6016            Impact factor:   1.675


  3 in total

Review 1.  Importance of Discriminative Measurement for Radon Isotopes and Its Utilization in the Environment and Lessons Learned from Using the RADUET Monitor.

Authors:  Chutima Kranrod; Yuki Tamakuma; Masahiro Hosoda; Shinji Tokonami
Journal:  Int J Environ Res Public Health       Date:  2020-06-10       Impact factor: 3.390

2.  The Importance of Direct Progeny Measurements for Correct Estimation of Effective Dose Due to Radon and Thoron.

Authors:  Guillaume Samuel Bineng; Shinji Tokonami; Masahiro Hosoda; Yvette Flore Tchuente Siaka; Hamadou Issa; Takahito Suzuki; Hiromi Kudo; Oumarou Bouba
Journal:  Front Public Health       Date:  2020-02-11

3.  Indoor Radon Measurements Using Radon Track Detectors and Electret Ionization Chambers in the Bauxite-Bearing Areas of Southern Adamawa, Cameroon.

Authors:  Oumar Bobbo Modibo; Ndjana Nkoulou Ii Joseph Emmanuel; Olga German; Kountchou Noube Michaux; Hamadou Yerima Abba
Journal:  Int J Environ Res Public Health       Date:  2020-09-17       Impact factor: 3.390

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.