Literature DB >> 31394901

Perspectives on and Precautions for the Uses of Electric Spectroscopic Methods in Label-free Biosensing Applications.

Beatriz L Garrote1, Adriano Santos1, Paulo R Bueno1.   

Abstract

Label-free approaches for molecular diagnostic applications are appealing because of their inherent point-of-care advantages. Nonetheless, technical challenges impose a limit on the use of these methods as will be discussed in this paper. Electrochemical spectroscopic methods, such as impedance and impedance-derived methods, are highly effective in the development of label-free diagnostic assays, but they require careful control of the dynamics of the sensing interface. We herein report the strength and challenges of the current methodologies associated with the applications of impedance and impedance-derived methods by focusing on their principles of operation. We demonstrate that the uses of their potentialities are not based on the know-how of these methods, but on how to combine the spectroscopic features with the required chemical design for the associated sensing interfaces. Predominantly, we illustrate how to use the resistive and capacitive terms of the interface to improve its sensitivity to the target. For instance, with the proper signal amplification strategy, limitations related to target-to-receptor size ratio can be overcome. The target-to-receptor ratio is one of the difficulties that we use as an example to illustrate how the sensing of an electric signal can be improved by controlling the properties of the interface on the nanometer scale.

Keywords:  biosensors; capacitive biosensors; charge transfer resistance; electrochemical capacitance; electrochemical impedance spectroscopy; label-free diagnostic; molecular assaying; point-of-care diagnostics

Mesh:

Year:  2019        PMID: 31394901     DOI: 10.1021/acssensors.9b01177

Source DB:  PubMed          Journal:  ACS Sens        ISSN: 2379-3694            Impact factor:   7.711


  7 in total

1.  Investigation to Minimize Electrochemical Impedance Spectroscopy Drift.

Authors:  Emily R Ziino; Sabrina Marnoto; Jeffrey M Halpern
Journal:  ECS Trans       Date:  2020

2.  Aerosol-jet-printed graphene electrochemical immunosensors for rapid and label-free detection of SARS-CoV-2 in saliva.

Authors:  Cícero C Pola; Sonal V Rangnekar; Robert Sheets; Beata M Szydlowska; Julia R Downing; Kshama W Parate; Shay G Wallace; Daphne Tsai; Mark C Hersam; Carmen L Gomes; Jonathan C Claussen
Journal:  2d Mater       Date:  2022-06-10       Impact factor: 6.861

Review 3.  Spectroscopic Methods Used in Implant Material Studies.

Authors:  Sławomir Lach; Przemysław Jurczak; Natalia Karska; Agnieszka Kubiś; Aneta Szymańska; Sylwia Rodziewicz-Motowidło
Journal:  Molecules       Date:  2020-01-29       Impact factor: 4.411

Review 4.  Advances in Electrochemical Impedance Spectroscopy Detection of Endocrine Disruptors.

Authors:  Lucian-Gabriel Zamfir; Mihaela Puiu; Camelia Bala
Journal:  Sensors (Basel)       Date:  2020-11-11       Impact factor: 3.576

5.  Establish pre-clinical diagnostic efficacy for parathyroid hormone as a point-of-surgery-testing-device (POST).

Authors:  Ambalika S Tanak; Sriram Muthukumar; Ibrahim A Hashim; Shalini Prasad
Journal:  Sci Rep       Date:  2020-11-02       Impact factor: 4.379

Review 6.  Label-Free Electrochemical Biosensors for the Determination of Flaviviruses: Dengue, Zika, and Japanese Encephalitis.

Authors:  Ekaterina Khristunova; Elena Dorozhko; Elena Korotkova; Bohumil Kratochvil; Vlastimil Vyskocil; Jiri Barek
Journal:  Sensors (Basel)       Date:  2020-08-16       Impact factor: 3.576

7.  Introducing polymer conductance in diagnostically relevant transduction.

Authors:  Ausra Baradoke; Adriano Santos; Paulo R Bueno; Jason J Davis
Journal:  Biosens Bioelectron       Date:  2020-10-22       Impact factor: 10.618

  7 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.