Literature DB >> 3139311

Capnographic detection of anaesthesia circle valve malfunctions.

L S Berman1, S T Pyles.   

Abstract

To determine whether capnographic waveforms can characterize valve malfunction of the anaesthesia circle, which would enable such problems to be identified and rectified immediately, we monitored capnographic respiratory waveforms during anaesthesia with simulated circle valve malfunctions. Ten mongrel dogs were anaesthetized with pentobarbitone, 25 mg.kg-1 IV, and halothane, 0.5 to 1 per cent. Respiratory gas was sampled from the elbow of the circle system for capnographic monitoring. At fresh gas flow rates of 2.5 or 5 L.min-1 during consecutive periods of controlled and spontaneous ventilation, the inspiratory valve, the expiratory valve, or both valves of the circle system were opened for 15 min. Inspired CO2 concentration increased significantly every time a valve was opened, except during spontaneous breathing at 5 L.min-1. At 2.5 L.min-1, inspired CO2 increased from baseline to 0.41 +/- 0.28 per cent with the inspiratory valve opened and to 2.22 +/- 1.72 per cent with the expiratory valve opened during controlled ventilation and to 0.43 +/- 0.20 per cent and 2.02 +/- 1.28 per cent, respectively, during spontaneous ventilation. Inspired CO2 increased to almost 1 per cent when the inspiratory valve was open and to greater than or equal to 1.89 per cent when the expiratory valve was open. The effects with the expiratory valve open and with both valves open were similar. Capnograms were affected in characteristic ways by the valve malfunctions.

Entities:  

Mesh:

Substances:

Year:  1988        PMID: 3139311     DOI: 10.1007/BF03026893

Source DB:  PubMed          Journal:  Can J Anaesth        ISSN: 0832-610X            Impact factor:   5.063


  1 in total

1.  Expiratory valve dysfunction in a semiclosed circle anesthesia circuit--verification by analysis of carbon dioxide waveform.

Authors:  S T Pyles; L S Berman; J H Modell
Journal:  Anesth Analg       Date:  1984-05       Impact factor: 5.108

  1 in total
  7 in total

Review 1.  Accident and emergency medicine--II.

Authors:  R C Evans; R J Evans
Journal:  Postgrad Med J       Date:  1992-10       Impact factor: 2.401

Review 2.  Capnometry and anaesthesia.

Authors:  K Bhavani-Shankar; H Moseley; A Y Kumar; Y Delph
Journal:  Can J Anaesth       Date:  1992-07       Impact factor: 5.063

3.  A system of classification for the clinical applications of capnography.

Authors:  Naveen Eipe; Jordan Tarshis
Journal:  J Clin Monit Comput       Date:  2007-10-09       Impact factor: 2.502

4.  The anesthesia machine valve tester: a new device and method for evaluating the competence of unidirectional anesthetic valves.

Authors:  S Eappen; S B Corn
Journal:  J Clin Monit       Date:  1996-07

Review 5.  A review of pediatric capnography.

Authors:  Naveen Eipe; Dermot R Doherty
Journal:  J Clin Monit Comput       Date:  2010-07-16       Impact factor: 2.502

6.  Inspiratory valve malfunction in a circle system: pitfalls in capnography.

Authors:  A Y Kumar; K Bhavani-Shankar; H S Moseley; Y Delph
Journal:  Can J Anaesth       Date:  1992-11       Impact factor: 5.063

Review 7.  Terminology and the current limitations of time capnography: a brief review.

Authors:  K Bhavani-Shankar; A Y Kumar; H S Moseley; R Ahyee-Hallsworth
Journal:  J Clin Monit       Date:  1995-05
  7 in total