| Literature DB >> 31390747 |
Vololoniaina Raharinosy1,2, Jean-Michel Heraud3,4, Harinirina Aina Rabemananjara1,2, Sandra Telfer5,6, Danielle Aurore Doll Rakoto2,7, Claudia Filippone1,2, Jean-Marc Reynes8.
Abstract
Genetic variants of Thailand orthohantavirus (THAIV) have been recently reported from rodents in South-East Asia and in islands from the South-West part of the Indian Ocean. In order to detect THAIV and its variants, we developed a sensitive and specific real-time RT-PCR targeting the S segment. Our assay was developed in two different RT-PCR systems that gave similar results in terms of sensitivity. Moreover, our results demonstrated a specificity of 100%.Entities:
Keywords: Hantavirus; Real-time RT-PCR; Thailand orthohantavirus
Mesh:
Substances:
Year: 2019 PMID: 31390747 PMCID: PMC6722858 DOI: 10.3390/v11080718
Source DB: PubMed Journal: Viruses ISSN: 1999-4915 Impact factor: 5.048
Primers and probe designed for the detection of the S segment of Thailand orthohantavirus and variants by real-time RT-PCR.
| Name | Sequence | Position * |
|---|---|---|
| THAIV F S | 5’-ATG GCA ACT ATG GAR GAG TTA CAG-3’ | 46–69 |
| THAIV R | 5’-ACA CTY TCM CGG TCA TGI AGT GC-3’ | 195–172 |
| THAIV P S | [FAM] 5’-CAR CTT GTG GTG GCW AGR CA-3’ [BHQ1] | 94–113 |
* According to the THAIV S sequence GenBank Acc. no AB186420.1 [19].
Limit of detection of Thailand orthohantavirus (Anjozorobe virus) assay by using the two platforms of real time RT-PCR.
| System | LightCycler 480 Instrument II (Roche) | Applied Biosystems 7500 (Applied-Biosystems) | Pan-Hantavirus Nested RT-PCR 1 |
|---|---|---|---|
| RT-PCR Reagents | SensiFAST Probe One-Step kit (Bioline) | SuperScript III Platinum One-Step Kit (Invitrogen) | |
| THAIV RNA Concentration (FFU/mL) 2 | Ct | Ct | |
| 3.45 × 105 | 21.1 | 18.7 | Positive |
| 3.45 × 104 | 24.6 | 22.8 | Positive |
| 3.45 × 103 | 27.8 | 26.9 | Positive |
| 3.45 × 102 | 31.5 | 30.8 | Positive |
| 3.45 × 101 | 34.3 | 32.9 | Positive |
| 3.45 | 36.4 | 36.2 | Positive |
| 3.45 × 10−1 | Negative | Negative | Negative |
| 3.45 × 10−2 | Negative | Negative | Negative |
1 Conventional RT-PCR according Klempa et al. [10]. 2 Thailand orthohantavirus reference virus (THAIV strain 749) RNA was extracted from a serial ten-fold dilution of a viral stock at 3.45 × 106 FFU/mL.
Specificity test of Thailand orthohantavirus (Anjozorobe virus) assay by using two different platforms of real time RT-PCR.
| System | LightCycler 480 Instrument II (Roche) | Applied Biosystems 7500 (Applied-Biosystems) |
|---|---|---|
| RT-PCR Reagents | SensiFAST Probe One-Step kit (Bioline) | SuperScript III Platinum One-Step Kit (Invitrogen) |
|
| ||
| THAIV | Positive | Positive |
| HTNV 2 | Negative | not tested |
| PUUV | Negative | Negative |
| SEOV 2 | Negative | not tested |
| ANJZV 3 | Positive | Positive |
| ANJZV 4 | Positive | Positive |
1 THAIV: Thailand orthohantavirus, HTNV: Hantaan orthohantavirus, PUUV: Puumala orthohantavirus, SEOV: Seoul orthohantavirus, ANJZV: Anjozorobe virus. 2 HTVN and SEOV strains were not available in Madagascar and then could only be tested at the National Reference Centre for Hantavirus in Lyon (France) using LightCycler 480 Instrument II (Roche, Meylan, France) system. 3 Sample with high viral load. 4 Sample with low viral load.
Methods comparison between rtRT-PCR using Applied Biosystems 7500 and reference method nested RT-PCR by Klempa et al. [10].
| Applied Biosystems 7500 (Our Assay) | Pan-Hantavirus Nested RT-PCR (Klempa) | |
|---|---|---|
| Positive | Negative | |
|
| 113 | 1 |
|
| 0 | 341 |