Literature DB >> 31389899

High Risk of Further Surgery After Radial Head Replacement for Unstable Fractures: Longer-term Outcomes at a Minimum Follow-up of 8 Years.

Caroline D Cristofaro1, Thomas H Carter, Neil R Wickramasinghe, Margaret M McQueen, Timothy O White, Andrew D Duckworth.   

Abstract

BACKGROUND: The evidence for treating acute, unreconstructable radial head fractures in unstable elbows with radial head replacement predominantly consists of short- to mid-term follow-up studies with a heterogenous mix of implants and operative techniques. Data on longer-term patient-reported outcomes after radial head replacement is lacking. QUESTIONS/PURPOSES: (1) What proportion of patients undergo revision or implant removal after radial head replacement? (2) At a minimum of 8 years follow-up, what are the patient-reported outcomes (QuickDASH, Oxford Elbow Score, and EuroQol-5D)? (3) What factors are associated with a superior long-term patient-reported outcome, according to the QuickDASH?
METHODS: Between September 1994 and September 2010, we surgically treated 157 patients for acute radial head fractures. We excluded patients where the radial head was excised (n = 21), internally fixed (n = 15), or replaced as a secondary procedure after failed internal fixation (n = 2). A total of 119 patients who underwent radial head replacement surgery for an acute unreconstructable fracture were included, with a mean age of 50 years (range 15 to 93 ± 19 years), and 53% of patients (63) were women. All but two implants were uncemented, loose-fitting, monopolar prostheses, of which 86% (102) were metallic and 14% (17) were silastic. Implants were only cemented if they appeared unstable within the proximal radius. Silastic implants were used in the earlier series and replaced by metallic implants starting in 2000. We reviewed electronic records to document postoperative complications and prosthesis revision and removal. A member of the local research team (THC, CDC) who was not previously involved in patient care contacted patients to confirm complications, reoperations and to obtain long-term patient-reported outcomes scores. Nineteen patients had died at the point of outcome score collection. Of the remaining 100 patients, 80 were contacted (67% of total cohort), at a median of 11 years (range 8 to 24 years) after injury. The primary outcome measure was the QuickDASH score.
RESULTS: Of 119 patients, 25% (30) underwent reoperation, with three patients undergoing revision and 27 patients undergoing prosthesis removal at a median of 7 months (range 0 to 125 months). Twenty-one of 30 procedures (70%) occurred within 1 year after implantation. Kaplan-Meier survivorship analysis demonstrated a cumulative implant survival rate of 71%. In the 80 patients contacted, the mean QuickDASH score was 13 ± 14, the mean Oxford Elbow Score was 43 ± 6, and the median EuroQol-5D score was 0.8 (-0.3 to 1.0). After controlling for covariates, we found that prothesis revision or removal (p = 0.466) and prosthesis type (p = 0.553) were not associated with patient-reported outcome, according to the QuickDASH.
CONCLUSIONS: The management of acute unreconstructable fractures of the radial head in unstable elbow injuries with radial head replacement has a high risk of reoperation. Patients must be counselled regarding this risk of secondary intervention, of which the peak risk appears to be within 1 year after implantation. Despite this, patients report low disability according to the QuickDASH at a minimum follow-up of 8 years. LEVEL OF EVIDENCE: Level IV, therapeutic study.

Entities:  

Mesh:

Year:  2019        PMID: 31389899      PMCID: PMC6903861          DOI: 10.1097/CORR.0000000000000876

Source DB:  PubMed          Journal:  Clin Orthop Relat Res        ISSN: 0009-921X            Impact factor:   4.176


  46 in total

1.  Mason type II radial head fractures: operative versus nonoperative treatment.

Authors:  E E Khalfayan; R W Culp; A H Alexander
Journal:  J Orthop Trauma       Date:  1992       Impact factor: 2.512

2.  Comparison between radial head replacement and open reduction and internal fixation in clinical treatment of unstable, multi-fragmented radial head fractures.

Authors:  Xiao Chen; Si-cheng Wang; Lie-hu Cao; Guo-qing Yang; Ming Li; Jia-can Su
Journal:  Int Orthop       Date:  2010-08-02       Impact factor: 3.075

Review 3.  Prosthesis replacement in Mason III radial head fractures: A meta-analysis.

Authors:  Q Dou; Z Yin; L Sun; X Feng
Journal:  Orthop Traumatol Surg Res       Date:  2015-08-28       Impact factor: 2.256

4.  Radial Head Fractures Treated with Modular Metallic Radial Head Replacement: Outcomes at a Mean Follow-up of Eight Years.

Authors:  Jonathan P Marsh; Ruby Grewal; Kenneth J Faber; Darren S Drosdowech; George S Athwal; Graham J W King
Journal:  J Bone Joint Surg Am       Date:  2016-04-06       Impact factor: 5.284

5.  Does radial head implant fixation affect functional outcomes? A systematic review and meta-analysis.

Authors:  Kofi D Agyeman; Dhanur Damodar; Ian Watkins; Seth D Dodds
Journal:  J Shoulder Elbow Surg       Date:  2018-10-17       Impact factor: 3.019

6.  Short to midterm outcomes of one hundred and seventy one MoPyC radial head prostheses: meta-analysis.

Authors:  Pierre Laumonerie; Meagan E Tibbo; Panagiotis Kerezoudis; Marc Olivier Gauci; Nicolas Reina; Nicolas Bonnevialle; Pierre Mansat
Journal:  Int Orthop       Date:  2018-07-30       Impact factor: 3.075

7.  Radial head replacement with a bipolar system: a minimum 2-year follow-up.

Authors:  Mark R Zunkiewicz; Jill S Clemente; Mark C Miller; Mark E Baratz; Robert W Wysocki; Mark S Cohen
Journal:  J Shoulder Elbow Surg       Date:  2011-10-28       Impact factor: 3.019

8.  Resection arthroplasty for radial head fractures: Long-term follow-up.

Authors:  Petrea P Iftimie; Jaume Calmet Garcia; Ignacio de Loyola Garcia Forcada; Jose Eduardo Gonzalez Pedrouzo; Josep Giné Gomà
Journal:  J Shoulder Elbow Surg       Date:  2011-01       Impact factor: 3.019

9.  Comparative responsiveness and minimal change for the Oxford Elbow Score following surgery.

Authors:  Jill Dawson; Helen Doll; Irene Boller; Ray Fitzpatrick; Christopher Little; Jonathan Rees; Andrew Carr
Journal:  Qual Life Res       Date:  2008-10-29       Impact factor: 4.147

10.  Radial head fracture. A potentially complex injury.

Authors:  P A Davidson; J B Moseley; H S Tullos
Journal:  Clin Orthop Relat Res       Date:  1993-12       Impact factor: 4.176

View more
  5 in total

1.  CORR Insights®: High Risk of Further Surgery After Radial Head Replacement for Unstable Fractures: Longer-term Outcomes at a Minimum Follow-up of 8 Years.

Authors:  David Ring
Journal:  Clin Orthop Relat Res       Date:  2019-11       Impact factor: 4.176

2.  30-Day outcomes analysis of surgical management of radial head fractures comparing radial head arthroplasty to open reduction internal fixation.

Authors:  Joshua P Weissman; Mark A Plantz; Erik B Gerlach; Colin K Cantrell; Bennet Butler
Journal:  J Orthop       Date:  2022-02-12

3.  Clinical long-term results of radial head arthroplasty in comminuted radial head fractures.

Authors:  T F Raven; A Moghaddam; S Studier-Fischer; P A Grützner; B Biglari
Journal:  Musculoskelet Surg       Date:  2022-03-30

4.  Patient and Surgeon Factors Associated With Prosthetic Replacement Rather Than With Open Reduction and Internal Fixation of a Radial Head Fracture.

Authors:  Casey M O'Connor; Joost Kortlever; Gregg A Vagner; Lee M Reichel; David Ring
Journal:  Hand (N Y)       Date:  2020-05-20

5.  CORR Insights®: What Factors Are Associated with Reoperation after Operative Treatment of Terrible Triad Injuries?

Authors:  W Angus Wallace
Journal:  Clin Orthop Relat Res       Date:  2021-01-01       Impact factor: 4.755

  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.