Literature DB >> 27053580

Radial Head Fractures Treated with Modular Metallic Radial Head Replacement: Outcomes at a Mean Follow-up of Eight Years.

Jonathan P Marsh1, Ruby Grewal2, Kenneth J Faber2, Darren S Drosdowech2, George S Athwal2, Graham J W King3.   

Abstract

BACKGROUND: Radial head arthroplasty is commonly used to treat acute unreconstructible radial head fractures. The purpose of this study was to report on the clinical and radiographic outcomes at a minimum follow-up of five years after radial head arthroplasty with a modular metallic implant for the treatment of acute radial head fractures.
METHODS: The cases of fifty-five patients with unreconstructible radial head fractures treated acutely with a smooth-stemmed modular metallic radial head implant were retrospectively reviewed. A wide variety of injuries, which ranged from isolated radial head fractures to so-called terrible triad injuries, were included. All patients returned for an interview, physical examination, and radiographic evaluation at a mean of eight years (range, five to fourteen years) postoperatively. Elbow and forearm motion, elbow strength, and grip strength were measured. Radiographs were evaluated, and validated patient-rated outcome questionnaires were completed. A longitudinal subgroup analysis was performed for thirty-three patients who were previously evaluated at two years postoperatively.
RESULTS: At a mean of 8.2 ± 2.9 years, the mean arc of flexion (and standard deviation) of the affected elbow was 11° ± 14° to 137° ± 15°. Elbow strength and motion were significantly diminished compared with the unaffected elbow (p < 0.05). The mean Mayo Elbow Performance Index (MEPI) was 91 ± 13 points. Twenty-five patients (45%) had stem lucencies; twenty-one (38%), ulnohumeral arthritis; and twenty (36%), heterotopic ossification, including one with radioulnar synostosis. Two patients underwent secondary elbow surgery, but no patient required implant removal or revision. In the subgroup evaluated longitudinally, there was a significant improvement in MEPI scores from the two-year to the eight-year follow-up (p = 0.012), with no loss of motion or strength (p > 0.05).
CONCLUSIONS: The mid-term outcomes of radial head arthroplasty with a smooth-stemmed modular metallic prosthesis are comparable with previously reported short-term outcomes, with no evidence of functional deterioration. Radial head arthroplasty with a smooth-stemmed metallic modular implant is a good treatment option for patients with acute unreconstructible radial head fractures, and sustained clinical outcomes may be expected beyond five years of follow-up. LEVEL OF EVIDENCE: Therapeutic Level IV. See Instructions for Authors for a complete description of levels of evidence.
Copyright © 2016 by The Journal of Bone and Joint Surgery, Incorporated.

Entities:  

Mesh:

Year:  2016        PMID: 27053580     DOI: 10.2106/JBJS.15.00128

Source DB:  PubMed          Journal:  J Bone Joint Surg Am        ISSN: 0021-9355            Impact factor:   5.284


  16 in total

1.  Mid-term clinical outcome comparison of long-stemmed monopolar osseointegrated and short-stemmed bipolar radial head prostheses.

Authors:  Yves Gramlich; Eva Krausch; Thomas Stein; Kai Schmidt-Horlohé; Reinhard Hoffmann; Alexander Klug
Journal:  Arch Orthop Trauma Surg       Date:  2020-07-27       Impact factor: 3.067

2.  Causes for early and late surgical re-intervention after radial head arthroplasty.

Authors:  Pierre Laumonerie; David Ancelin; Nicolas Reina; Meagan E Tibbo; Panagiotis Kerezoudis; Stephanie Delclaux; Nicolas Bonnevialle; Pierre Mansat
Journal:  Int Orthop       Date:  2017-05-12       Impact factor: 3.075

3.  Short to midterm outcomes of one hundred and seventy one MoPyC radial head prostheses: meta-analysis.

Authors:  Pierre Laumonerie; Meagan E Tibbo; Panagiotis Kerezoudis; Marc Olivier Gauci; Nicolas Reina; Nicolas Bonnevialle; Pierre Mansat
Journal:  Int Orthop       Date:  2018-07-30       Impact factor: 3.075

4.  Complications after radial head arthroplasty: a comparison between short-stemmed bipolar and monopolar long-stemmed osteointegrative rigidly fixed prostheses.

Authors:  Yves Gramlich; Eva-Lorine Krausch; Alexander Klug; Johannes Buckup; Kay Schmidt-Horlohé; Reinhard Hoffmann
Journal:  Int Orthop       Date:  2018-09-29       Impact factor: 3.075

Review 5.  Radial head prosthesis: surgical tips and tricks.

Authors:  A Marinelli; E Guerra; A Ritali; M Cavallo; R Rotini
Journal:  Musculoskelet Surg       Date:  2017-10-09

6.  Tight-fitting radial head prosthesis: does stem size help prevent painful loosening?

Authors:  Pierre Laumonerie; Nicolas Reina; Claudia Gutierrez; Stephanie Delclaux; Meagan E Tibbo; Nicolas Bonnevialle; Pierre Mansat
Journal:  Int Orthop       Date:  2017-09-21       Impact factor: 3.075

Review 7.  Radial head fractures.

Authors:  R P van Riet; Mpj van den Bekerom; A Van Tongel; C Spross; R Barco; A C Watts
Journal:  Shoulder Elbow       Date:  2019-09-25

8.  High Risk of Further Surgery After Radial Head Replacement for Unstable Fractures: Longer-term Outcomes at a Minimum Follow-up of 8 Years.

Authors:  Caroline D Cristofaro; Thomas H Carter; Neil R Wickramasinghe; Margaret M McQueen; Timothy O White; Andrew D Duckworth
Journal:  Clin Orthop Relat Res       Date:  2019-11       Impact factor: 4.176

9.  Treatment of Radial Head Fractures with a Modular Metallic Radial Head Replacement.

Authors:  Robert Longstaffe; Graham J W King; Jonathan P Marsh
Journal:  JBJS Essent Surg Tech       Date:  2017-03-08

Review 10.  Indications and outcomes of radial head excision: A systematic review.

Authors:  Alexandra H Hildebrand; Betty Zhang; Nolan S Horner; Graham King; Moin Khan; Bashar Alolabi
Journal:  Shoulder Elbow       Date:  2019-07-31
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.