Literature DB >> 31383516

Laser-Calibrated System for Transnasal Fiberoptic Laryngeal High-Speed Videoendoscopy.

Dimitar D Deliyski1, Milen Shishkov2, Daryush D Mehta3, Hamzeh Ghasemzadeh4, Brett Bouma2, Matias Zañartu5, Alessandro de Alarcon6, Robert E Hillman3.   

Abstract

The design specifications and experimental characteristics of a newly developed laser-projection transnasal flexible endoscope coupled with a high-speed videoendoscopy system are provided. The hardware and software design of the proposed system benefits from the combination of structured green light projection and laser triangulation techniques, which provide the capability of calibrated absolute measurements of the laryngeal structures along the horizontal and vertical planes during phonation. Visual inspection of in vivo acquired images demonstrated sharp contrast between laser points and background, confirming successful design of the system. Objective analyses were carried out for assessing the irradiance of the system and the penetration of the green laser light into the red and blue channels in the recorded images. The analysis showed that the system has irradiance of 372 W/m2 at a working distance of 20 mm, which is well within the safety limits, indicating minimal risk of usage of the device on human subjects. Additionally, the color penetration analysis showed that, with probability of 90%, the ratio of contamination of the red channel from the green laser light is less than 0.002. This indicates minimal effect of the laser projection on the measurements performed on the red data channel, making the system applicable for calibrated 3D spatial-temporal segmentation and data-driven subject-specific modeling, which is important for further advancing voice science and clinical voice assessment.
Copyright © 2019 The Voice Foundation. Published by Elsevier Inc. All rights reserved.

Entities:  

Keywords:  Flexible endoscopy; High-speed videoendoscopy; Laser calibration; Spatial calibrated measurements; Vocal fold vibration

Mesh:

Year:  2019        PMID: 31383516      PMCID: PMC6995434          DOI: 10.1016/j.jvoice.2019.07.013

Source DB:  PubMed          Journal:  J Voice        ISSN: 0892-1997            Impact factor:   2.009


  4 in total

1.  Framework for Indirect Spatial Calibration of the Horizontal Plane of Endoscopic Laryngeal Images.

Authors:  Hamzeh Ghasemzadeh; Dimitar D Deliyski; Robert E Hillman; Daryush D Mehta
Journal:  J Voice       Date:  2022-01-02       Impact factor: 2.300

2.  External Validity of Calibrated Measurements from a Laser-Projection Transnasal Fiberoptic High-Speed Videoendoscopy System.

Authors:  Hamzeh Ghasemzadeh; Ali Imani Azad; Dimitar D Deliyski
Journal:  J Voice       Date:  2022-01-31       Impact factor: 2.300

3.  Method for Horizontal Calibration of Laser-Projection Transnasal Fiberoptic High-Speed Videoendoscopy.

Authors:  Hamzeh Ghasemzadeh; Dimitar D Deliyski; Robert E Hillman; Daryush D Mehta
Journal:  Appl Sci (Basel)       Date:  2021-01-17       Impact factor: 2.679

4.  Comparative analysis of high-speed videolaryngoscopy images and sound data simultaneously acquired from rigid and flexible laryngoscope: a pilot study.

Authors:  Wioletta Pietruszewska; Marcin Just; Joanna Morawska; Jakub Malinowski; Joanna Hoffman; Anna Racino; Magda Barańska; Magdalena Kowalczyk; Ewa Niebudek-Bogusz
Journal:  Sci Rep       Date:  2021-10-14       Impact factor: 4.379

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.