Literature DB >> 31374457

Is MPS always the answer? Use of two PCR-based methods for Y-chromosomal haplotyping in highly and moderately degraded bone material.

Maria Szargut1, Marta Diepenbroek2, Grażyna Zielińska3, Sandra Cytacka3, Joanna Arciszewska3, Katarzyna Jałowińska3, Jarosław Piątek3, Andrzej Ossowski3.   

Abstract

Forensic and population genetics often rely on Y-chromosomal studies. Whether it is a human identification case, trace evidence examination or phylogenetic analysis, a Y-STR haplotype is an important tool in the hands of law enforcement agencies. A common obstacle in achieving satisfactory results in all of the above mentioned circumstances, is low DNA quantity and quality within samples obtained. In this study we have examined Y-STR haplotypes in 75 bone material samples, coming from different time periods. For this purpose we have chosen YFiler Plus PCR Amplification Kit (ThermoFisher Scientific) and ForenSeq Signature DNA Prep Kit (Verogen Inc.), which use two different allele calling technologies - capillary electrophoresis and Massively Parallel Sequencing respectively. Full profiles were obtained from DNA extracts with as little as 0.1896 ng (Degradation Index 1.3) (ForenSeq) and 0.0591 ng (Degradation Index 26.8) (YFiler Plus) DNA input. The results that we present in this paper show differences in amplification rates between common markers in both kits. The differences strictly reflect mean amplicon length of markers. This, however, does not seem to influence Y-haplogroup estimation results noticeably. In one sample a discordance occurred between haplotypes obtained with both methods, where a 24 allele was called in DYS390 marker by capillary electrophoresis, while for the same sample in this locus a 23 allele was shown with MPS. A reason for this is yet to be investigated. The sequence analysis revealed a significant variation between isometric alleles, especially within repetitive regions of studied Y-STR markers.
Copyright © 2019 Elsevier B.V. All rights reserved.

Entities:  

Keywords:  Bone material; Degradation; Flanking region; Haplotyping; Human identification; MPS; Y-STR

Mesh:

Year:  2019        PMID: 31374457     DOI: 10.1016/j.fsigen.2019.07.016

Source DB:  PubMed          Journal:  Forensic Sci Int Genet        ISSN: 1872-4973            Impact factor:   4.882


  2 in total

1.  Development and validation of a novel 133-plex forensic STR panel (52 STRs and 81 Y-STRs) using single-end 400 bp massive parallel sequencing.

Authors:  Haoliang Fan; Lingxiang Wang; Changhui Liu; Xiaoyu Lu; Xuding Xu; Kai Ru; Pingming Qiu; Chao Liu; Shao-Qing Wen
Journal:  Int J Legal Med       Date:  2021-11-06       Impact factor: 2.791

2.  The forensic landscape and the population genetic analyses of Hainan Li based on massively parallel sequencing DNA profiling.

Authors:  Haoliang Fan; Zhengming Du; Fenfen Wang; Xiao Wang; Shao-Qing Wen; Lingxiang Wang; Panxin Du; Hai Liu; Shengping Cao; Zhenming Luo; Bingbing Han; Peiyu Huang; Bofeng Zhu; Pingming Qiu
Journal:  Int J Legal Med       Date:  2021-04-13       Impact factor: 2.686

  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.