Literature DB >> 31353004

Efficacy and Safety of Ultrathin, Bioresorbable-Polymer Sirolimus-Eluting Stents Versus Thin, Durable-Polymer Everolimus-Eluting Stents for Coronary Revascularization of Patients With Diabetes Mellitus.

Ron Waksman1, Evan Shlofmitz2, Stephan Windecker3, Jacques J Koolen4, Shigeru Saito5, David Kandzari6, Paul Kolm2, Michael J Lipinski2, Rebecca Torguson2.   

Abstract

Patients with diabetes mellitus are prone to increased adverse outcomes after percutaneous coronary intervention, even with contemporary drug-eluting stents. Randomized controlled trials have demonstrated comparable clinical outcomes between an ultrathin bioresorbable-polymer sirolimus-eluting stent (BP-SES) and a thin-strut durable-polymer everolimus-eluting stent (DP-EES) that has specific labeling for patients with diabetes. We aimed to evaluate the safety and efficacy of the BP-SES in patients with diabetes mellitus. To determine the performance of the BP-SES in diabetic patients, patient-level data from the BIOFLOW II, IV, and V randomized controlled trials were pooled. The primary end point was target lesion failure (TLF), defined as the composite of cardiovascular death, target-vessel myocardial infarction, ischemia-driven target lesion revascularization, and definite or probable stent thrombosis, at 1 year. Among 1,553 BP-SES and 791 DP-EES patients, 757 diabetic patients were identified. Of the diabetic patients included in this analysis (494 BP-SES vs 263 DP-EES), the proportion of insulin- and noninsulin-treated patients was similar between groups. The 1-year TLF rate in the diabetic population was 6.3% in the BP-SES group and 8.7% in the DP-EES group (hazard ratio 0.82, 95% confidence interval 0.047 to 1.43, p = 0.493). There were no significant differences, based on stent type or diabetes treatment regimen, in TLF hazards. In a patient-level pooled analysis of the diabetic population from randomized trials, 1-year clinical safety and efficacy outcomes were similar in patients treated with ultrathin BP-SES and thin-strut DP-EES.
Copyright © 2019. Published by Elsevier Inc.

Entities:  

Mesh:

Substances:

Year:  2019        PMID: 31353004     DOI: 10.1016/j.amjcard.2019.06.021

Source DB:  PubMed          Journal:  Am J Cardiol        ISSN: 0002-9149            Impact factor:   2.778


  2 in total

1.  Clinical outcome of biodegradable polymer sirolimus-eluting stent and durable polymer everolimus-eluting stent in patients with diabetes.

Authors:  Ryota Kakizaki; Yoshiyasu Minami; Masahiro Katamine; Aritomo Katsura; Yusuke Muramatsu; Takuya Hashimoto; Kentaro Meguro; Takao Shimohama; Junya Ako
Journal:  Cardiovasc Diabetol       Date:  2020-10-01       Impact factor: 9.951

2.  Cardiovascular outcomes associated with Ultrathin bioresorbable polymer sirolimus eluting stents versus thin, durable polymer everolimus eluting stents following percutaneous coronary intervention in patients with type 2 diabetes mellitus: A meta-analysis of published studies.

Authors:  Shibing Deng; Xuying Yi; Zhiming Tian
Journal:  Medicine (Baltimore)       Date:  2020-12-24       Impact factor: 1.817

  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.