Literature DB >> 31346702

[New DIN and ISO norms for determination of visual acuity].

W Wesemann1, S P Heinrich2, H Jägle3, U Schiefer4,5, M Bach2.   

Abstract

Recently, three international norms (ISO) for visual acuity assessment were revised. The DIN EN ISO 8596:2018 stipulates the Landolt C eye chart as the standard optotype and specifies display characteristics. An informative annex lists clinical optotypes for the first time. These include the ETDRS chart, Snellen chart and pediatric optotypes; however, these clinical optotypes do not have the same status as the Landolt C chart, since even with identical font size and stroke width they may differ in recognizability. The technical report ISO/TR 19498:2015 complements DIN EN ISO 8596. A scientifically appropriate procedure is described, which enables a quantitative correlation of clinical optotypes with the Landolt C chart. The DIN EN ISO 10938:2016 describes the required optical quality of optotypes. For the first time, electronic devices are explicitly approved for standardized visual acuity tests. Consequently, according to this amendment electronic devices may be used for acuity assessment for ophthalmological expert opinions according to DIN 58220, part 3.

Entities:  

Keywords:  Crowding; Decimal visual acuity; LogMAR; Snellen fraction; Visual acuity

Mesh:

Year:  2020        PMID: 31346702     DOI: 10.1007/s00347-019-0943-x

Source DB:  PubMed          Journal:  Ophthalmologe        ISSN: 0941-293X            Impact factor:   1.059


  4 in total

1.  [New DIN norms for determination of visual acuity].

Authors:  W Wesemann; U Schiefer; M Bach
Journal:  Ophthalmologe       Date:  2010-09       Impact factor: 1.059

Review 2.  Anti-aliasing and dithering in the 'Freiburg Visual Acuity Test'.

Authors:  M Bach
Journal:  Spat Vis       Date:  1997

3.  [A new test (C-test) for quantitative examination of crowding with test results in amblyopic and ametropic patients (author's transl)].

Authors:  W Haase; A Hohmann
Journal:  Klin Monbl Augenheilkd       Date:  1982-03       Impact factor: 0.700

Review 4.  Crowding--an essential bottleneck for object recognition: a mini-review.

Authors:  Dennis M Levi
Journal:  Vision Res       Date:  2008-01-28       Impact factor: 1.886

  4 in total
  1 in total

1.  Quantification of the Dynamic Visual Acuity Space at Real-World Luminances and Contrasts: The VA-CAL Test.

Authors:  Julian Hilmers; Torsten Straßer; Michael Bach; Katarina Stingl; Eberhart Zrenner
Journal:  Transl Vis Sci Technol       Date:  2022-04-01       Impact factor: 3.048

  1 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.