Ultrasound confirmation of endotracheal tube placement.

D T Raphael1, F U Conard.   

Abstract

Real-time B-mode ultrasound imaging was performed in 24 intubated patients in order to confirm the correct placement of endotracheal tubes. The large acoustic impedance mismatch between the air within the endotracheal tube cuff and the tracheal wall could be bypassed by (1) use of a foam-cuffed Bivona endotracheal tube, or by (2) cuff inflation with saline instead of air. Optimal repositioning of the endotracheal tube could be done under direct visualization. Imaging of the foam-filled and saline-filled cuffs was easier in the longitudinal (sagittal) than in the transverse view, was enhanced by a slight longitudinal to-and-fro motion of the tube, and was often improved with the use of a stand-off pad. Cases of esophageal intubation were not considered. Use of a noninvasive imaging modality such as ultrasound will spare selected patients from the radiation exposure associated with a chest x-ray. This is of value in pregnant patients and in those requiring frequent chest radiographs for the sole purpose of confirming correct endotracheal tube placement. Limitations of the techniques are discussed.

Entities:  

Mesh:

Year:  1987        PMID: 3134447     DOI: 10.1002/jcu.1870150706

Source DB:  PubMed          Journal:  J Clin Ultrasound        ISSN: 0091-2751            Impact factor:   0.910


  8 in total

Review 1.  Ultrasonography for endotracheal tube position in infants and children.

Authors:  Pooja Jaeel; Mansi Sheth; Jimmy Nguyen
Journal:  Eur J Pediatr       Date:  2017-01-13       Impact factor: 3.183

2.  Ultrasound of the airway.

Authors:  Pankaj Kundra; Sandeep Kumar Mishra; Anathakrishnan Ramesh
Journal:  Indian J Anaesth       Date:  2011-09

3.  A feasibility study on bedside upper airway ultrasonography compared to waveform capnography for verifying endotracheal tube location after intubation.

Authors:  Osman Adi; Tan Wan Chuan; Manikam Rishya
Journal:  Crit Ultrasound J       Date:  2013-07-04

4.  Determining correct tracheal tube insertion depth by measuring distance between endotracheal tube cuff and vocal cords by ultrasound in Chinese adults: a prospective case-control study.

Authors:  Xuanling Chen; Wenwen Zhai; Zhuoying Yu; Jiao Geng; Min Li
Journal:  BMJ Open       Date:  2018-12-06       Impact factor: 2.692

5.  Ultrasound for diagnosing new difficult laryngoscopy indicator: a prospective, self-controlled, assessor blinded, observational study.

Authors:  Lei Wang; Yan-Kun Feng; Liu Hong; Wan-Li Xie; Shi-Qiang Chen; Ping Yin; Qing-Ping Wu
Journal:  Chin Med J (Engl)       Date:  2019-09-05       Impact factor: 2.628

6.  Laryngo-tracheal ultrasonography to confirm correct endotracheal tube and laryngeal mask airway placement.

Authors:  Jacek A Wojtczak; Davide Cattano
Journal:  J Ultrason       Date:  2014-12-30

7.  Sensitivity and Specificity of a Novel Approach to Confirm the Depth of the Endotracheal Tube: A Pilot Study.

Authors:  Yansong Li; Ying Xie; Bailong Hu; Jing Wang; Haibo Song; Xinchuan Wei
Journal:  Medicine (Baltimore)       Date:  2015-08       Impact factor: 1.817

Review 8.  [Ultrasound guided airway access].

Authors:  Neusa Lages; Diana Vieira; Joana Dias; Cláudia Antunes; Tiago Jesus; Telmo Santos; Carlos Correia
Journal:  Braz J Anesthesiol       Date:  2018-09-20
  8 in total