Literature DB >> 31337927

Coupled Active Shape Models for Automated Segmentation and Landmark Localization in High-Resolution CT of the Foot and Ankle.

M Brehler1, A Islam1, L Vogelsang2, D Yang2, W Sehnert2, D Shakoor3, S Demehri3, J H Siewerdsen1,3, W Zbijewski1.   

Abstract

PURPOSE: We develop an Active Shape Model (ASM) framework for automated bone segmentation and anatomical landmark localization in weight-bearing Cone-Beam CT (CBCT). To achieve a robust shape model fit in narrow joint spaces of the foot (0.5 - 1 mm), a new approach for incorporating proximity constraints in ASM (coupled ASM, cASM) is proposed.
METHODS: In cASM, shape models of multiple adjacent foot bones are jointly fit to the CBCT volume. This coupling enables checking for proximity between the evolving shapes to avoid situations where a conventional single-bone ASM might erroneously fit to articular surfaces of neighbouring bones. We used 21 extremity CBCT scans of the weight-bearing foot to compare segmentation and landmark localization accuracy of ASM and cASM in leave-one-out validation. Each scan was used as a test image once; shape models of calcaneus, talus, navicular, and cuboid were built from manual surface segmentations of the remaining 20 scans. The models were augmented with seven anatomical landmarks used for common measurements of foot alignment. The landmarks were identified in the original CBCT volumes and mapped onto mean bone shape surfaces. ASM and cASM were run for 100 iterations, and the number of principal shape components was increased every 10 iterations. Automated landmark localization was achieved by applying known point correspondences between landmark vertices on the mean shape and vertices of the final active shape segmentation of the test image.
RESULTS: Root Mean Squared (RMS) error of bone surface segmentation improved from 3.6 mm with conventional ASM to 2.7 mm with cASM. Furthermore, cASM achieved convergence (no change in RMS error with iteration) after ~40 iterations of shape fitting, compared to ~60 iterations for ASM. Distance error in landmark localization was 25% to 55% lower (depending on the landmark) with cASM than with ASM. The importance of using a coupled model is underscored by the finding that cASM detected and corrected collisions between evolving shapes in 50% to 80% (depending on the bone) of shape model fits.
CONCLUSION: The proposed cASM framework improves accuracy of shape model fits, especially in complexes of tightly interlocking, articulated joints. The approach enables automated anatomical analysis in volumetric imaging of the foot and ankle, where narrow joint spaces challenge conventional shape models.

Entities:  

Keywords:  Cone-beam CT; active shape models; bone segmentation; landmark identification; weight-bearing CT

Year:  2019        PMID: 31337927      PMCID: PMC6647836          DOI: 10.1117/12.2515022

Source DB:  PubMed          Journal:  Proc SPIE Int Soc Opt Eng        ISSN: 0277-786X


  8 in total

1.  Point set registration: coherent point drift.

Authors:  Andriy Myronenko; Xubo Song
Journal:  IEEE Trans Pattern Anal Mach Intell       Date:  2010-12       Impact factor: 6.226

2.  Atlas-based automatic measurements of the morphology of the tibiofemoral joint.

Authors:  M Brehler; G Thawait; W Shyr; J Ramsay; J H Siewerdsen; W Zbijewski
Journal:  Proc SPIE Int Soc Opt Eng       Date:  2017-03-13

3.  Cone-beam CT measurements of distal tibio-fibular syndesmosis in asymptomatic uninjured ankles: does weight-bearing matter?

Authors:  Delaram Shakoor; Greg M Osgood; Michael Brehler; Wojciech B Zbijewski; Cesar de Cesar Netto; Babar Shafiq; Jakrapong Orapin; Gaurav K Thawait; Lew C Shon; Shadpour Demehri
Journal:  Skeletal Radiol       Date:  2018-09-21       Impact factor: 2.199

4.  Weight-bearing CT imaging of the lower extremity.

Authors:  Esa K J Tuominen; Jussi Kankare; Seppo K Koskinen; Kimmo T Mattila
Journal:  AJR Am J Roentgenol       Date:  2013-01       Impact factor: 3.959

5.  Dedicated cone-beam CT system for extremity imaging.

Authors:  John A Carrino; Abdullah Al Muhit; Wojciech Zbijewski; Gaurav K Thawait; J Webster Stayman; Nathan Packard; Robert Senn; Dong Yang; David H Foos; John Yorkston; Jeffrey H Siewerdsen
Journal:  Radiology       Date:  2013-11-18       Impact factor: 11.105

6.  Combination of pedCAT® for 3D Imaging in Standing Position With Pedography Shows No Statistical Correlation of Bone Position With Force/Pressure Distribution.

Authors:  Martinus Richter; Stefan Zech; Sarah Hahn; Issam Naef; David Merschin
Journal:  J Foot Ankle Surg       Date:  2016 Mar-Apr       Impact factor: 1.286

7.  Flexible Adult Acquired Flatfoot Deformity: Comparison Between Weight-Bearing and Non-Weight-Bearing Measurements Using Cone-Beam Computed Tomography.

Authors:  Cesar de Cesar Netto; Lew C Schon; Gaurav K Thawait; Lucas Furtado da Fonseca; Apisan Chinanuvathana; Wojciech B Zbijewski; Jeffrey H Siewerdsen; Shadpour Demehri
Journal:  J Bone Joint Surg Am       Date:  2017-09-20       Impact factor: 5.284

8.  Articular surface segmentation using active shape models for intraoperative implant assessment.

Authors:  Joseph Görres; Michael Brehler; Jochen Franke; Sven Y Vetter; Paul A Grützner; Hans-Peter Meinzer; Ivo Wolf
Journal:  Int J Comput Assist Radiol Surg       Date:  2016-04-19       Impact factor: 2.924

  8 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.