Literature DB >> 31331663

Magnetic resonance imaging based modeling of microvascular perfusion in patients with peripheral artery disease.

Olga A Gimnich1, Jaykrishna Singh2, Jean Bismuth2, Dipan J Shah2, Gerd Brunner3.   

Abstract

Peripheral artery disease (PAD) is associated with an increased risk of adverse cardiovascular events, impaired lower extremity blood flow and microvascular perfusion abnormalities in the calf muscles which can be determined with contrast-enhanced magnetic resonance imaging (CE-MRI). We developed a computational model of the microvascular perfusion in the calf muscles. We included 20 patients (10 PAD, 10 controls) and utilized the geometry, mean signal intensity and arterial input functions from CE-MRI calf muscle perfusion scans. The model included the microvascular pressure (pv), outflow filtration coefficient (OFC), transfer rate constant (kt), porosity (φ), and the interstitial permeability (Ktissue). Parameters were fitted and the simulations were compared across PAD patients and controls. Intra-observer reproducibility of the simulated mean signal intensities was excellent (intraclass correlation coefficients >0.995). kt and Ktissue were higher in PAD patients compared with controls (4.72 interquartile range (IQR) 3.33, 5.56 vs. 2.47 IQR 2.10, 2.85; p = 0.003; and 3.68 IQR 3.18, 4.41 vs. 1.81 IQR 1.81, 1.81; p < 0.001). Conversely, porosity (φ) was lower in PAD patients compared with controls (0.52 IQR 0.49, 0.54 vs. 0.61 IQR 0.58, 0.64; p = 0.016). Porosity (φ) was correlated with the ankle brachial index (r = 0.64, p = 0.011). The proposed computational microvascular model is robust and reproducible, and essential model parameters differ significantly between PAD patients and controls.
Copyright © 2019 Elsevier Ltd. All rights reserved.

Entities:  

Keywords:  Computational fluid dynamics; Magnetic resonance imaging; Microvascular circulation; Modeling; Peripheral artery disease

Mesh:

Year:  2019        PMID: 31331663     DOI: 10.1016/j.jbiomech.2019.06.025

Source DB:  PubMed          Journal:  J Biomech        ISSN: 0021-9290            Impact factor:   2.712


  2 in total

1.  Experimental Validation of Perfusion Imaging With HOSVD Clutter Filters.

Authors:  Yang Zhu; MinWoo Kim; Cameron Hoerig; Michael F Insana
Journal:  IEEE Trans Ultrason Ferroelectr Freq Control       Date:  2020-04-21       Impact factor: 2.725

2.  Relation of Magnetic Resonance Imaging Based Arterial Signal Enhancement to Markers of Peripheral Artery Disease.

Authors:  Olga A Gimnich; Jonathan Holbrook; Tatiana Belousova; Christina M Short; Addison A Taylor; Vijay Nambi; Joel D Morrisett; Christie M Ballantyne; Jean Bismuth; Dipan J Shah; Gerd Brunner
Journal:  Am J Cardiol       Date:  2020-11-02       Impact factor: 2.778

  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.