| Literature DB >> 31318910 |
Joanna Gołębiewska1, Karolina Biała-Gosek1, Agnieszka Czeszyk1, Wojciech Hautz1.
Abstract
PURPOSE: To assess the superficial retinal vessel density (SRVD) and foveal avascular zone (FAZ) in myopic children using optical coherence tomography angiography (OCTA).Entities:
Mesh:
Year: 2019 PMID: 31318910 PMCID: PMC6639003 DOI: 10.1371/journal.pone.0219785
Source DB: PubMed Journal: PLoS One ISSN: 1932-6203 Impact factor: 3.240
Fig 1Representative OCTA vessel density report of myopic eye.
Figure panel shows: the image of the macular vessels, separately calculated in five regions (fovea, temporal, superior, nasal and inferior) based on the ETDRS contour, OCT en face image, B-scans, and outcomes of quantitative analysis by the software.
Fig 2Histogram depicting the distribution of axial length in the studied patients by presence of myopia and gender.
Characteristics of the studied patients.
| Variable | Statistical parameter | |||
|---|---|---|---|---|
| 13.9 | 2.3 | 13.6–14.3 | 9–17 | |
| 13.1 | 2.4 | 12.7–13.6 | 9–18 | |
| –3.61 | 2.48 | –3.08 to –4.14 | –0.25 to –11.75 | |
| –3.30 | 2.44 | –2.76 to –3.83 | –0.25 to –12.00 | |
| 24.58 | 1.22 | 24.40–24.76 | 22.04–28.48 | |
| 22.88 | 0.65 | 22.75–23.01 | 21.46–24.14 | |
(M—mean; SD—standard deviation; CI—confidence interval. Multivariate analyses were performed, taking into account the patients’ age and sex)
Descriptive statistics for selected features of the fovea and the parafovea in the studied patients by presence of myopia.
| Variable | Myopic | Non-myopic | * Level of statistical significance | ||||||
|---|---|---|---|---|---|---|---|---|---|
| 0.258 | 0.091 | 0.245–0.272 | 0.029–0.563 | 0.224 | 0.076 | 0.209–0.239 | 0.004–0.446 | ||
| 48.03 | 4.04 | 47.24–48.83 | 37.04–57.76 | 54.54 | 6.04 | 53.64–55.45 | 39.93–77.67 | ||
| 31.64 | 4.82 | 30.92–32.36 | 19.75–44.09 | 31.63 | 4.40 | 30.76–32.47 | 22.00–40.22 | ||
| 53.18 | 3.33 | 52.68–53.67 | 41.94–62.08 | 54.51 | 3.08 | 53.90–55.12 | 42.64–59.06 | ||
| 252.09 | 18.56 | 249.31–254.86 | 204–292 | 251.11 | 19.93 | 247.17–255.04 | 213–316 | ||
| 311.80 | 18.90 | 308.97–314.63 | 195–356 | 321.22 | 13.55 | 318.54–323.89 | 284–350 | ||
(M—mean; SD—standard deviation; CI—confidence interval. Multivariate analyses were performed, taking into account the patients’ age and sex)
Pearson’s correlation coefficients and p-values for the axial length and spherical equivalent versus selected traits in the studied patients by presence of myopia.
| Study group | Myopic | Non-myopic | Overall | |||||
|---|---|---|---|---|---|---|---|---|
| Dependent variable | Axial length | Spherical equivalent | Axial length | Axial length | ||||
| Statistical parameter | ||||||||
| 0.34 | < 0.001 | 0.34 | < 0.001 | –0.03 | = 0.700 | 0.31 | < 0.001 | |
| –0.14 | = 0.145 | –0.06 | = 0.502 | –0.16 | = 0.163 | –0.19 | = 0.014 | |
| –0.22 | = 0.014 | –0.24 | = 0.007 | 0.14 | = 0.231 | –0.21 | = 0.008 | |
| 0.15 | = 0.109 | 0.08 | = 0.366 | 0.15 | = 0.190 | 0.19 | = 0.014 | |
| –0.23 | = 0.009 | –0.24 | = 0.005 | 0.13 | = 0.251 | –0.22 | = 0.005 | |
| 0.13 | = 0.169 | 0.07 | = 0.447 | 0.17 | = 0.154 | 0.18 | = 0.024 | |
| –0.18 | = 0.126 | –0.17 | = 0.158 | 0.08 | = 0.370 | –0.20 | = 0.010 | |
* Pearson product-moment correlation coefficient;
† level of statistical significance.
Multivariate analyses were carried out, hence all the correlation coefficients and p-values shown were controlled for the studied patients’ age and sex, except the age that was corrected for sex only)