Literature DB >> 31316260

Bilateral proximal tibia stress fracture following bilateral distal femoral hemiepiphysiodesis - A rare complication.

R Thangaraj1, Farhan Ali1.   

Abstract

Correction of lower limb deformities by hemiepiphyseodesis with 8-plates is gaining popularity among deformity surgeons. Complications including metal failure, recurrence of deformity have been reported but stress fracture has not been reported. We have encountered bilateral proximal metaphyseal tibia stress fractures following correction of valgus deformity of both knees by hemiepiphyseodesis of distal femur following inadvertent overcorrection to a varus deformity following loss of follow up. The varus deformity has been reversed by guided growth of distal femoral physis resulting in fracture union and normal gait pattern. We herewith emphasize the importance of timely follow up with removal of 8 plates for hemiepiphysiodesis in deformity correction to prevent unexpected complication. We are reporting a rare complication of proximal tibial stress fractures following distal femur hemiepiphysiodesis done for valgus deformity with 8-plates.

Entities:  

Year:  2018        PMID: 31316260      PMCID: PMC6611963          DOI: 10.1016/j.jcot.2018.06.003

Source DB:  PubMed          Journal:  J Clin Orthop Trauma        ISSN: 0976-5662


  6 in total

1.  Radiographic Results and Complications of 3 Guided Growth Implants.

Authors:  Yong-Woon Shin; Samir K Trehan; Tyler J Uppstrom; Roger F Widmann; Daniel W Green
Journal:  J Pediatr Orthop       Date:  2018-08       Impact factor: 2.324

2.  Mechanical failures of eight-plateguided growth system for temporary hemiepiphysiodesis.

Authors:  Rolf D Burghardt; Stacy C Specht; John E Herzenberg
Journal:  J Pediatr Orthop       Date:  2010-09       Impact factor: 2.324

3.  Lower Extremity Deformity Management in MPS IVA, Morquio-Brailsford Syndrome: Preliminary Report of Hemiepiphysiodesis Correction of Genu Valgum.

Authors:  George A Cooper; Thomas Southorn; Deborah M Eastwood; C Edward Bache
Journal:  J Pediatr Orthop       Date:  2016-06       Impact factor: 2.324

4.  Failure of Orthofix eight-Plate for the treatment of Blount disease.

Authors:  Samuel Schroerlucke; Styles Bertrand; John Clapp; Justin Bundy; Frederick O Gregg
Journal:  J Pediatr Orthop       Date:  2009 Jan-Feb       Impact factor: 2.324

5.  Correction of lower extremity angular deformities in skeletal dysplasia with hemiepiphysiodesis: a preliminary report.

Authors:  Guney Yilmaz; Murat Oto; Ahmed M Thabet; Kenneth J Rogers; Darko Anticevic; Mihir M Thacker; William G Mackenzie
Journal:  J Pediatr Orthop       Date:  2014 Apr-May       Impact factor: 2.324

6.  Comparative study between staples and eight plate in the management of coronal plane deformities of the knee in skeletally immature children.

Authors:  Arvind Kumar; Sahil Gaba; Alok Sud; Pushpvardhan Mandlecha; Lakshay Goel; Mayur Nayak
Journal:  J Child Orthop       Date:  2016-07-14       Impact factor: 1.548

  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.