S S Malik1, S Malik1, R Shenoy2, M D Jones1, P S Theobald1. 1. Bioengineering Research Group, Cardiff School of Engineering, Cardiff University, Queens Buildings, The Parade, Newport Road, Cardiff, CF24 3AA, UK. 2. Department of Trauma & Orthopaedics, St Mary's Hospital, Imperial College Healthcare NHS Trust, Praed Street, London, W2 1NY, UK.
Abstract
INTRODUCTION: The risk of fracture from a non-accidental injury is highest in the infant age group. A spiral fracture of the long bone can occur equally from accidental and non-accidental causes, meaning the clinical judgement of non-accidental injury in an infant is particularly challenging. This study aimed to assist in differentiating accidental, from non-accidental, injury in infants, by establishing whether correlation exists between geometry and torsional strength in the immature long bone. METHODS: Immature porcine third and fourth metacarpals (n = 21) were imaged with a dual energy x-ray absorptiometry (DEXA) scanner to measure their linear bone mineral content (BMCL), bone mineral density (BMD) and section modulus (Z). The specimens were then subjected to a torque of one degree per second until failure. The failure strength and the three DEXA measures were analyzed for a correlation. RESULTS: The mean failure strength of 11 successful tests was 13.71Nm (+/-SD 2.42Nm), with correlation to BMCL, BMD and Z described by r2 = 0.81, 0.283 and 0.75 respectively. CONCLUSION: This study is a novel attempt at estimating torsional strength of long bones in a specific paediatric age group using a size-matched animal bone model. It found a strong correlation between bone and fracture strength parameters over the BMCL range of 0.59-0.77 g/cm.
INTRODUCTION: The risk of fracture from a non-accidental injury is highest in the infant age group. A spiral fracture of the long bone can occur equally from accidental and non-accidental causes, meaning the clinical judgement of non-accidental injury in an infant is particularly challenging. This study aimed to assist in differentiating accidental, from non-accidental, injury in infants, by establishing whether correlation exists between geometry and torsional strength in the immature long bone. METHODS: Immature porcine third and fourth metacarpals (n = 21) were imaged with a dual energy x-ray absorptiometry (DEXA) scanner to measure their linear bone mineral content (BMCL), bone mineral density (BMD) and section modulus (Z). The specimens were then subjected to a torque of one degree per second until failure. The failure strength and the three DEXA measures were analyzed for a correlation. RESULTS: The mean failure strength of 11 successful tests was 13.71Nm (+/-SD 2.42Nm), with correlation to BMCL, BMD and Z described by r2 = 0.81, 0.283 and 0.75 respectively. CONCLUSION: This study is a novel attempt at estimating torsional strength of long bones in a specific paediatric age group using a size-matched animal bone model. It found a strong correlation between bone and fracture strength parameters over the BMCL range of 0.59-0.77 g/cm.
Authors: Alison M Kemp; Frank Dunstan; Sara Harrison; Susan Morris; Mala Mann; Kim Rolfe; Shalini Datta; D Phillip Thomas; Jonathan R Sibert; Sabine Maguire Journal: BMJ Date: 2008-10-02
Authors: Grzegorz Tymicki; Iwona Puzio; Marta Pawłowska-Olszewska; Marek Bieńko; Radosław Piotr Radzki Journal: Animals (Basel) Date: 2022-03-04 Impact factor: 2.752