| Literature DB >> 31316236 |
Venkat C Kavuri1, Kranthikiran Earasi1, Matthew Varacallo1, Susan P Harding1.
Abstract
Complications following tibial intramedullary nailing include anterior knee pain, malunion, nonunion, and symptomatic/prominent interlocking screws. We report a case of a posterior tibial tendon tear caused by placement of a distal interlocking screw which was detected via dynamic ultrasound. This is a rare and possibly underreported complication which could be the cause of persistent medial sided ankle pain following locked tibial nail placement.Entities:
Keywords: Nail; PTT; Tendon; Tibia
Year: 2018 PMID: 31316236 PMCID: PMC6611837 DOI: 10.1016/j.jcot.2018.08.015
Source DB: PubMed Journal: J Clin Orthop Trauma ISSN: 0976-5662