Literature DB >> 31312944

Test-retest repeatability of the pattern electroretinogram and flicker electroretinogram.

Arthur F Resende1, Carina T Sanvicente1, Hamoon Eshraghi2, Alberto Garcia3, Kassandra Pickel3, Qiang Zhang4, Michael Waisbourd5, L Jay Katz6.   

Abstract

PURPOSE: To evaluate the repeatability of the steady-state pattern electroretinogram (PERG) and full-field flicker electroretinogram (Flicker ERG) protocols, delivered by the office-based Neuro Optic Vision Assessment (NOVA)™ testing platform, in healthy subjects.
METHODS: Healthy individuals underwent PERG (16° and 24°) and Flicker ERG [fixed luminance (FL) and multi-luminance (ML)] testing protocols. Test-retest repeatability of protocols was calculated using intra-class correlation coefficients (ICC). Reference values of the parameters of the aforementioned tests were also calculated.
RESULTS: The ICCs for the PERG parameters ranged from 0.793 to 0.911 (p < 0.001). The ICCs for the Flicker ERG parameters ranged from 0.968 to 0.994 (p < 0.001). A linear regression analysis was applied to assess the impact of age on ERG responses. Age had a significant impact on all PERG parameters (16° or 24°). The phase response of the FL Flicker ERG significantly decreased with age (β = - 0.837, p ≤ 0.001). The FL Flicker ERG Magnitude was also impacted with a significant quadratic effect of age (β = - 0.0047, p = 0.0004). Similarly, the Phase Area Under the Curve (Phase AUC) of the ML Flicker ERG significantly declined with age (β = - 0.007, p = 0.009), and the impact on the Magnitude AUC was significant as well, with a negative quadratic age effect.
CONCLUSIONS: The PERG and Flicker ERG protocols, delivered by an office-based testing platform, were shown to have good-to-excellent test-retest repeatability when tests were performed in the same order and in immediate succession.

Entities:  

Keywords:  Electrophysiology; Flicker electroretinogram; Reference database; Repeatability; Steady-state pattern electroretinogram

Year:  2019        PMID: 31312944     DOI: 10.1007/s10633-019-09707-5

Source DB:  PubMed          Journal:  Doc Ophthalmol        ISSN: 0012-4486            Impact factor:   2.379


  44 in total

1.  Neural losses correlated with visual losses in clinical perimetry.

Authors:  Ronald S Harwerth; Louvenia Carter-Dawson; Earl L Smith; George Barnes; William F Holt; Morris L J Crawford
Journal:  Invest Ophthalmol Vis Sci       Date:  2004-09       Impact factor: 4.799

2.  Report from the NEI/FDA Ophthalmic Clinical Trial Design and Endpoints Symposium.

Authors:  Karl G Csaky; Elaine A Richman; Frederick L Ferris
Journal:  Invest Ophthalmol Vis Sci       Date:  2008-02       Impact factor: 4.799

3.  Flicker electroretinograms before and after intravitreal ranibizumab injection in eyes with central retinal vein occlusion.

Authors:  Shunsuke Yasuda; Shu Kachi; Shinji Ueno; Chang-Hua Piao; Hiroko Terasaki
Journal:  Acta Ophthalmol       Date:  2015-01-18       Impact factor: 3.761

4.  Progressive loss of retinal ganglion cell function precedes structural loss by several years in glaucoma suspects.

Authors:  Michael R Banitt; Lori M Ventura; William J Feuer; Eleonore Savatovsky; Gabriel Luna; Olga Shif; Brandon Bosse; Vittorio Porciatti
Journal:  Invest Ophthalmol Vis Sci       Date:  2013-03-28       Impact factor: 4.799

5.  Human flicker electroretinography using different temporal modulations at mesopic and photopic luminance levels.

Authors:  Balázs Vince Nagy; Mirella Telles Salgueiro Barboni; Cristiane Maria Gomes Martins; Marcelo Fernandes da Costa; Jan Kremers; Dora Fix Ventura
Journal:  Doc Ophthalmol       Date:  2014-06-27       Impact factor: 2.379

6.  Neural conduction in visual pathways in newly-diagnosed IDDM patients.

Authors:  V Parisi; L Uccioli; L Parisi; G Colacino; G Manni; G Menzinger; M G Bucci
Journal:  Electroencephalogr Clin Neurophysiol       Date:  1998-09

7.  Reproducibility of pattern electroretinogram in glaucoma patients with a range of severity of disease with the new glaucoma paradigm.

Authors:  Marie-Josée Fredette; Douglas R Anderson; Vittorio Porciatti; William Feuer
Journal:  Ophthalmology       Date:  2007-11-05       Impact factor: 12.079

8.  Repeatability of pattern electroretinogram measurements using a new paradigm optimized for glaucoma detection.

Authors:  Christopher Bowd; Ali Tafreshi; Gianmarco Vizzeri; Linda M Zangwill; Pamela A Sample; Robert N Weinreb
Journal:  J Glaucoma       Date:  2009-08       Impact factor: 2.503

9.  Can Variability of Pattern ERG Signal Help to Detect Retinal Ganglion Cells Dysfunction in Glaucomatous Eyes?

Authors:  Alberto Mavilio; Francesca Scrimieri; Donato Errico
Journal:  Biomed Res Int       Date:  2015-06-08       Impact factor: 3.411

Review 10.  Role of Electrophysiology in the Early Diagnosis and Follow-Up of Diabetic Retinopathy.

Authors:  Nicola Pescosolido; Andrea Barbato; Alessio Stefanucci; Giuseppe Buomprisco
Journal:  J Diabetes Res       Date:  2015-05-05       Impact factor: 4.011

View more
  3 in total

1.  Aging effects on contrast sensitivity in visual pathways: A pilot study on flicker adaptation.

Authors:  Xiaohua Zhuang; Tam Tran; Doris Jin; Riya Philip; Chaorong Wu
Journal:  PLoS One       Date:  2021-12-31       Impact factor: 3.240

2.  Pattern Electroretinogram Parameters and their Associations with Optical Coherence Tomography in Glaucoma Suspects.

Authors:  Andrew Tirsi; Amanda Wong; Daniel Zhu; Guillaume Stoffels; Peter Derr; Celso Tello Md
Journal:  J Curr Glaucoma Pract       Date:  2022 May-Aug

3.  Short-Term Steady-State Pattern Electroretinography Changes Using a Multi-Pressure Dial in Ocular Hypertensive, Glaucoma Suspect, and Mild Open-Angle Glaucoma Patients: A Randomized, Controlled, Prospective, Pilot Study.

Authors:  Jeremy J Kudrna; Tanner J Ferguson; Russell J Swan; Steven J Ferguson; Brandon J Baartman; Adam R Bleeker; Ramu G Sudhagoni; John P Berdahl; Michael D Greenwood
Journal:  Ophthalmol Ther       Date:  2020-09-16
  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.