Literature DB >> 31309438

Assessment of tear meniscus by optical coherence tomography in patients with canalicular laceration repair.

Seyda Karadenız Ugurlu1, Meryem Altın Ekın2, Hasan Aytogan3.   

Abstract

PURPOSE: To analyze tear meniscus measurements with optical coherence tomography (OCT) in patients with canalicular laceration repair.
METHODS: Thirty-four consecutive patients who underwent unilateral canalicular repair due to canalicular laceration between January 2014 and December 2018 were included. All patients had canalicular repair followed by monocanalicular or annular silicone tube intubation. Anatomic patency of canalicular system was tested with probing and irrigation, while functional patency was evaluated with Munk score. Tear meniscus measurements of all patients were obtained following tube removal by spectral OCT. Tear meniscus height (TMH), tear meniscus depth (TMD) and tear meniscus area (TMA) of eyes with canalicular laceration repair and contralateral uninvolved eyes were compared.
RESULTS: Average age of 34 patients was 32.8 ± 21.3 years (range 4-68 years). Lower canaliculus was involved in 27 (79.4%), upper canaliculus in five (14.7%), and both canaliculi in two (5.9%) patients. Mean follow-up period was 6.5 ± 5.7 months. Anatomic patency rate was 100%, and functional patency (patients free of epiphora) was 91.2%. Average TMH (317.9 ± 133.1 µm), TMD (198.1 ± 82.5 µm) and TMA (29,792.1 ± 21,285.3 μm2) values of eyes with canalicular repair were not significantly different from TMH (308.9 ± 111.9 µm), TMD (184.5 ± 61.4 µm) and TMA (26,682.5 ± 16,178.1 μm2) values of contralateral control eyes (p values: 0.758, 0.225 and 0.778, respectively). There was a strong positive correlation between TMA and Munk score (r = 0.637, p < 0.001) and moderate positive correlation between TMH (r = 521, p = 0.002), TMD (r = 0.481, p = 0.004) and Munk score.
CONCLUSION: Tear meniscus measurement with OCT is a rapid, quantitative and objective tool for evaluation of canalicular patency in patients with canalicular laceration repair.

Entities:  

Keywords:  Canalicular laceration; Epiphora; Munk score; Optical coherence tomography; Tear meniscus

Mesh:

Year:  2019        PMID: 31309438     DOI: 10.1007/s10792-019-01147-z

Source DB:  PubMed          Journal:  Int Ophthalmol        ISSN: 0165-5701            Impact factor:   2.031


  23 in total

1.  Tear meniscus volume in dry eye after punctal occlusion.

Authors:  Feng Chen; Meixiao Shen; Wei Chen; Jianhua Wang; Ming Li; Yimin Yuan; Fan Lu
Journal:  Invest Ophthalmol Vis Sci       Date:  2009-11-20       Impact factor: 4.799

2.  NIH Image to ImageJ: 25 years of image analysis.

Authors:  Caroline A Schneider; Wayne S Rasband; Kevin W Eliceiri
Journal:  Nat Methods       Date:  2012-07       Impact factor: 28.547

3.  The agreement and repeatability of tear meniscus height measurement methods.

Authors:  Michael Edward Johnson; Paul James Murphy
Journal:  Optom Vis Sci       Date:  2005-12       Impact factor: 1.973

4.  Application of visante optical coherence tomography tear meniscus height measurement in the diagnosis of dry eye disease.

Authors:  Osama M A Ibrahim; Murat Dogru; Yoji Takano; Yoshiyuki Satake; Tais Hitomi Wakamatsu; Kazumi Fukagawa; Kazuo Tsubota; Hiroshi Fujishima
Journal:  Ophthalmology       Date:  2010-06-03       Impact factor: 12.079

5.  Reproducibility of tear meniscus measurement by Fourier-domain optical coherence tomography: a pilot study.

Authors:  Sheng Zhou; Yan Li; Ake Tzu-Hui Lu; Pengfei Liu; Maolong Tang; Samuel C Yiu; David Huang
Journal:  Ophthalmic Surg Lasers Imaging       Date:  2009 Sep-Oct

Review 6.  Optical coherence tomography--current and future applications.

Authors:  Mehreen Adhi; Jay S Duker
Journal:  Curr Opin Ophthalmol       Date:  2013-05       Impact factor: 3.761

7.  Clinical assessment of the lower tear meniscus height.

Authors:  Carlos García-Resúa; Jacinto Santodomingo-Rubido; Madalena Lira; Maria Jesus Giraldez; Eva Yebra-Pimentel Vilar
Journal:  Ophthalmic Physiol Opt       Date:  2009-06-30       Impact factor: 3.117

8.  Tear meniscus volume changes in dacryocystorhinostomy evaluated with quantitative measurement using anterior segment optical coherence tomography.

Authors:  Kazuyoshi Ohtomo; Takashi Ueta; Reina Fukuda; Tomohiko Usui; Takashi Miyai; Rika Shirakawa; Shiro Amano; Miyuki Nagahara
Journal:  Invest Ophthalmol Vis Sci       Date:  2014-04-03       Impact factor: 4.799

9.  The challenge of dry eye diagnosis.

Authors:  Giacomo Savini; Pinita Prabhawasat; Takashi Kojima; Martin Grueterich; Edgar Espana; Eiki Goto
Journal:  Clin Ophthalmol       Date:  2008-03

Review 10.  Applications of Anterior Segment Optical Coherence Tomography in Cornea and Ocular Surface Diseases.

Authors:  Sang Beom Han; Yu-Chi Liu; Karim Mohamed Noriega; Jodhbir S Mehta
Journal:  J Ophthalmol       Date:  2016-09-19       Impact factor: 1.909

View more
  1 in total

1.  Comparing the symmetry of upper eyelid following unilateral ptosis correction.

Authors:  Hasan Aytogan; Emre Ayıntap
Journal:  BMC Ophthalmol       Date:  2021-12-20       Impact factor: 2.209

  1 in total