The present letter investigates a novel control approach for magnetically driven soft-tethered capsules for colonoscopy-a potentially painless approach for colon inspection. The focus of this work is on a class of devices composed of a magnetic capsule endoscope actuated by a single external permanent magnet. Actuation is achieved by manipulating the external magnet with a serial manipulator, which in turn produces forces and torques on the internal magnetic capsule. We propose a control strategy which, counteracting gravity, achieves levitation of the capsule. This technique, based on a nonlinear backstepping approach, is able to limit contact with the colon walls, reducing friction, avoiding contact with internal folds, and facilitating the inspection of nonplanar cavities. The approach is validated on an experimental setup, which embodies a general scenario faced in colonoscopy. The experiments show that we can attain 19.5% of contact with the colon wall, compared to the almost 100% of previously proposed approaches. Moreover, we show that the control can be used to navigate the capsule through a more realistic environment-a colon phantom-with reasonable completion time.

Entities:  

Keywords:  Medical robots and systems; force control; motion control

Year:  2019        PMID: 31304240      PMCID: PMC6625788          DOI: 10.1109/LRA.2019.2894907

Source DB:  PubMed          Journal:  IEEE Robot Autom Lett


  13 in total

1.  Novel, magnetically guided catheter for endocardial mapping and radiofrequency catheter ablation.

Authors:  Mitchell N Faddis; Walter Blume; Jennifer Finney; Andrew Hall; John Rauch; Jon Sell; Kyongtae Ty Bae; Michael Talcott; Bruce Lindsay
Journal:  Circulation       Date:  2002-12-03       Impact factor: 29.690

2.  Magnetic air capsule robotic system: proof of concept of a novel approach for painless colonoscopy.

Authors:  P Valdastri; G Ciuti; A Verbeni; A Menciassi; P Dario; A Arezzo; M Morino
Journal:  Surg Endosc       Date:  2011-12-17       Impact factor: 4.584

3.  Wireless therapeutic endoscopic capsule: in vivo experiment.

Authors:  P Valdastri; C Quaglia; E Susilo; A Menciassi; P Dario; C N Ho; G Anhoeck; M O Schurr
Journal:  Endoscopy       Date:  2008-12-08       Impact factor: 10.093

4.  Nonholonomic Closed-loop Velocity Control of a Soft-tethered Magnetic Capsule Endoscope.

Authors:  Addisu Z Taddese; Piotr R Slawinski; Keith L Obstein; Pietro Valdastri
Journal:  Rep U S       Date:  2016-12-01

5.  Enhanced Real-Time Pose Estimation for Closed-Loop Robotic Manipulation of Magnetically Actuated Capsule Endoscopes.

Authors:  Addisu Z Taddese; Piotr R Slawinski; Marco Pirotta; Elena De Momi; Keith L Obstein; Pietro Valdastri
Journal:  Int J Rob Res       Date:  2018-06-25       Impact factor: 4.703

6.  Experimental Validation of the Pseudo-Rigid-Body Model of the MRI-Actuated Catheter.

Authors:  Tipakorn Greigarn; Russell Jackson; Taoming Liu; M Cenk Çavuşoğlu
Journal:  IEEE Int Conf Robot Autom       Date:  2017-07-24

7.  Experimental assessment of a novel robotically-driven endoscopic capsule compared to traditional colonoscopy.

Authors:  Alberto Arezzo; Arianna Menciassi; Pietro Valdastri; Gastone Ciuti; Gioia Lucarini; Marco Salerno; Christian Di Natali; Mauro Verra; Paolo Dario; Mario Morino
Journal:  Dig Liver Dis       Date:  2013-02-28       Impact factor: 4.088

Review 8.  Management of vascular access in transcatheter aortic valve replacement: part 2: Vascular complications.

Authors:  Stefan Toggweiler; Jonathon Leipsic; Ronald K Binder; Melanie Freeman; Marco Barbanti; Robin H Heijmen; David A Wood; John G Webb
Journal:  JACC Cardiovasc Interv       Date:  2013-08       Impact factor: 11.195

9.  Initial experience with remote catheter ablation using a novel magnetic navigation system: magnetic remote catheter ablation.

Authors:  Sabine Ernst; Feifan Ouyang; Christian Linder; Klaus Hertting; Fabian Stahl; Julian Chun; Hitoshi Hachiya; Dietmar Bänsch; Matthias Antz; Karl-Heinz Kuck
Journal:  Circulation       Date:  2004-03-15       Impact factor: 29.690

10.  Quantitative assessment of colorectal morphology: Implications for robotic colonoscopy.

Authors:  A Alazmani; A Hood; D Jayne; A Neville; P Culmer
Journal:  Med Eng Phys       Date:  2016-01-04       Impact factor: 2.242

View more
  11 in total

1.  Adaptive Dynamic Control for Magnetically Actuated Medical Robots.

Authors:  Lavinia Barducci; Giovanni Pittiglio; Joseph C Norton; Keith L Obstein; Pietro Valdastri
Journal:  IEEE Robot Autom Lett       Date:  2019-07-15

2.  Simultaneous Independent Translational and Rotational Feedback Motion Control System for a Cylindrical Magnet using Planar Arrays of Magnetic Sensors and Cylindrical Coils.

Authors:  Peter Berkelman; Bernadette Tix
Journal:  IEEE Magn Lett       Date:  2020-11-17       Impact factor: 1.549

3.  Telerobotic neurovascular interventions with magnetic manipulation.

Authors:  Yoonho Kim; Emily Genevriere; Pablo Harker; Jaehun Choe; Marcin Balicki; Robert W Regenhardt; Justin E Vranic; Adam A Dmytriw; Aman B Patel; Xuanhe Zhao
Journal:  Sci Robot       Date:  2022-04-13

4.  Active Stabilization of Interventional Tasks Utilizing a Magnetically Manipulated Endoscope.

Authors:  Lavinia Barducci; Bruno Scaglioni; James Martin; Keith L Obstein; Pietro Valdastri
Journal:  Front Robot AI       Date:  2022-04-14

Review 5.  Magnetic Soft Materials and Robots.

Authors:  Yoonho Kim; Xuanhe Zhao
Journal:  Chem Rev       Date:  2022-02-01       Impact factor: 72.087

Review 6.  [Robots in the operating room-(co)operation during surgery].

Authors:  F Mathis-Ullrich; P M Scheikl
Journal:  Gastroenterologe       Date:  2020-12-22

7.  Application of robotic technologies in lower gastrointestinal tract endoscopy: A systematic review.

Authors:  Harpreet Kaur Sekhon Inderjit Singh; Emily Rose Armstrong; Sujay Shah; Reza Mirnezami
Journal:  World J Gastrointest Endosc       Date:  2021-12-16

8.  Enabling the future of colonoscopy with intelligent and autonomous magnetic manipulation.

Authors:  James W Martin; Bruno Scaglioni; Joseph C Norton; Venkataraman Subramanian; Alberto Arezzo; Keith L Obstein; Pietro Valdastri
Journal:  Nat Mach Intell       Date:  2020-10-12

9.  Endoluminal Motion Recognition of a Magnetically-Guided Capsule Endoscope Based on Capsule-Tissue Interaction Force.

Authors:  Peisen Zhang; Jing Li; Weimin Zhang; Yang Hao; Gastone Ciuti; Tatsuo Arai; Paolo Dario; Qiang Huang
Journal:  Sensors (Basel)       Date:  2021-03-30       Impact factor: 3.576

Review 10.  Endorobots for Colonoscopy: Design Challenges and Available Technologies.

Authors:  Luigi Manfredi
Journal:  Front Robot AI       Date:  2021-07-14
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.