Literature DB >> 3129961

Extending the detection limit of solid-phase electrochemical enzyme immunoassay to the attomole level.

S H Jenkins1, W R Heineman, H B Halsall.   

Abstract

Electrochemical enzyme immunoassay methodology has been developed to take advantage of the selectivity of antibody reactions, the amplification feature of an enzyme-based assay, and the ease with which small amounts of the enzyme-generated product can be detected electrochemically. A heterogeneous sandwich enzyme immunoassay was used in this work as the model assay. In this type of assay, the antigen is sandwiched between the enzyme conjugate and a primary antibody that is adsorbed to the solid phase. Alkaline phosphatase is a suitable enzyme for electrochemical assays since it catalyzes the conversion of electroinactive phenyl phosphate to electroactive phenol. The product, phenol, is then quantitated by liquid chromatography with electrochemical detection in a thin-layer flow cell with a carbon paste electrode at 0.895 V vs Ag/AgCl. The current produced by the oxidation of phenol is directly proportional to the analyte (antigen) concentration. The problem associated with these types of solid-phase immunoassays is that the adsorption of the primary antibody is desired while the adsorption of other assay proteins is not. The detection limits are generally defined by the ability to control this nonspecific adsorption. The detection limit of a previous electrochemical assay for rabbit IgG was 100 pg/ml and was limited by a large background current observed in the absence of antigen. In the present study, each step of the assay was examined in order to determine the sources of this background current, and it was found that the major contribution was from the nonspecific adsorption of the enzyme conjugate. Using combinations of Tween 20 and bovine serum albumin as blocking agents, the level of nonspecific adsorption was reduced by 96%.(ABSTRACT TRUNCATED AT 250 WORDS)

Entities:  

Mesh:

Substances:

Year:  1988        PMID: 3129961     DOI: 10.1016/0003-2697(88)90321-1

Source DB:  PubMed          Journal:  Anal Biochem        ISSN: 0003-2697            Impact factor:   3.365


  5 in total

1.  Amplification immunoassay for the determination of hepatitis B surface antigen.

Authors:  A Seki; E Tamiya; I Karube
Journal:  Appl Biochem Biotechnol       Date:  1991-03       Impact factor: 2.926

Review 2.  Nanomaterial-Based Electrochemical Immunosensors for Clinically Significant Biomarkers.

Authors:  Niina J Ronkainen; Stanley L Okon
Journal:  Materials (Basel)       Date:  2014-06-19       Impact factor: 3.623

3.  Genosensor on gold films with enzymatic electrochemical detection of a SARS virus sequence.

Authors:  Patricia Abad-Valle; M Teresa Fernández-Abedul; Agustín Costa-García
Journal:  Biosens Bioelectron       Date:  2005-05-15       Impact factor: 10.618

4.  SERS detection of Clostridium botulinum neurotoxin serotypes A and B in buffer and serum: Towards the development of a biodefense test platform.

Authors:  China Y Lim; Jennifer H Granger; Marc D Porter
Journal:  Anal Chim Acta X       Date:  2018-12-21

Review 5.  Aptamer-Based Technologies in Foodborne Pathogen Detection.

Authors:  Jun Teng; Fang Yuan; Yingwang Ye; Lei Zheng; Li Yao; Feng Xue; Wei Chen; Baoguang Li
Journal:  Front Microbiol       Date:  2016-09-12       Impact factor: 5.640

  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.