BACKGROUND: Open surgical closure and small-bore suture-based preclosure devices have limitations when used for transcatheter aortic valve replacement, percutaneous endovascular abdominal aortic aneurysm repair, or percutaneous thoracic endovascular aortic aneurysm repair. The MANTA vascular closure device is a novel collagen-based technology designed to close large bore arteriotomies created by devices with an outer diameter ranging from 12F to 25F. In this study, we determined the safety and effectiveness of the MANTA vascular closure device. METHODS AND RESULTS: A prospective, single arm, multicenter investigation in patients undergoing transcatheter aortic valve replacement, percutaneous endovascular abdominal aortic aneurysm repair, or thoracic endovascular aortic aneurysm repair at 20 sites in North America. The primary outcome was time to hemostasis. The primary safety outcomes were accessed site-related vascular injury or bleeding complications. A total of 341 patients, 78 roll-in, and 263 in the primary analysis cohort, were entered in the study between November 2016 and September 2017. For the primary analysis cohort, transcatheter aortic valve replacement was performed in 210 (79.8%), and percutaneous endovascular abdominal aortic aneurysm repair or thoracic endovascular aortic aneurysm repair was performed in 53 (20.2%). The 14F MANTA was used in 42 cases (16%), and the 18F was used in 221 cases(84%). The mean effective sheath outer diameter was 22F (7.3 mm). The mean time to hemostasis was 65±157 seconds with a median time to hemostasis of 24 seconds. Technical success was achieved in 257 (97.7%) patients, and a single device was deployed in 262 (99.6%) of cases. Valve Academic Research Consortium-2 major vascular complications occurred in 11 (4.2%) cases: 4 received a covered stent (1.5%), 3 had access site bleeding (1.1%), 2 underwent surgical repair (0.8%), and 2 underwent balloon inflation (0.8%). CONCLUSIONS: In a selected population, this study demonstrated that the MANTA percutaneous vascular closure device can safely and effectively close large bore arteriotomies created by current generation transcatheter aortic valve replacement, percutaneous endovascular abdominal aortic aneurysm repair, and thoracic endovascular aortic aneurysm repair devices. CLINICAL TRIAL REGISTRATION: URL: https://www.clinicaltrials.gov . Unique identifier: NCT02908880.
BACKGROUND: Open surgical closure and small-bore suture-based preclosure devices have limitations when used for transcatheter aortic valve replacement, percutaneous endovascular abdominal aortic aneurysm repair, or percutaneous thoracic endovascular aortic aneurysm repair. The MANTA vascular closure device is a novel collagen-based technology designed to close large bore arteriotomies created by devices with an outer diameter ranging from 12F to 25F. In this study, we determined the safety and effectiveness of the MANTA vascular closure device. METHODS AND RESULTS: A prospective, single arm, multicenter investigation in patients undergoing transcatheter aortic valve replacement, percutaneous endovascular abdominal aortic aneurysm repair, or thoracic endovascular aortic aneurysm repair at 20 sites in North America. The primary outcome was time to hemostasis. The primary safety outcomes were accessed site-related vascular injury or bleeding complications. A total of 341 patients, 78 roll-in, and 263 in the primary analysis cohort, were entered in the study between November 2016 and September 2017. For the primary analysis cohort, transcatheter aortic valve replacement was performed in 210 (79.8%), and percutaneous endovascular abdominal aortic aneurysm repair or thoracic endovascular aortic aneurysm repair was performed in 53 (20.2%). The 14F MANTA was used in 42 cases (16%), and the 18F was used in 221 cases(84%). The mean effective sheath outer diameter was 22F (7.3 mm). The mean time to hemostasis was 65±157 seconds with a median time to hemostasis of 24 seconds. Technical success was achieved in 257 (97.7%) patients, and a single device was deployed in 262 (99.6%) of cases. Valve Academic Research Consortium-2 major vascular complications occurred in 11 (4.2%) cases: 4 received a covered stent (1.5%), 3 had access site bleeding (1.1%), 2 underwent surgical repair (0.8%), and 2 underwent balloon inflation (0.8%). CONCLUSIONS: In a selected population, this study demonstrated that the MANTA percutaneous vascular closure device can safely and effectively close large bore arteriotomies created by current generation transcatheter aortic valve replacement, percutaneous endovascular abdominal aortic aneurysm repair, and thoracic endovascular aortic aneurysm repair devices. CLINICAL TRIAL REGISTRATION: URL: https://www.clinicaltrials.gov . Unique identifier: NCT02908880.
Authors: Herbert G Kroon; Pim A L Tonino; Mikko Savontaus; Giovanni Amoroso; Mika Laine; Evald H Christiansen; Stefan Toggweiler; Jur Ten Berg; Janarthanan Sathananthan; Joost Daemen; Peter P de Jaegere; Guus B R G Brueren; Markus Malmberg; Ton Slagboom; Noriaki Moriyama; Christian J Terkelsen; Federico Moccetti; Livia Gheorghe; John Webb; David Wood; Nicolas M Van Mieghem Journal: Catheter Cardiovasc Interv Date: 2020-12-21 Impact factor: 2.692
Authors: Maarten P van Wiechen; Herbert Kroon; Thijmen W Hokken; Joris F Ooms; Marjo J de Ronde-Tillmans; Joost Daemen; Peter P de Jaegere; Nicolas M Van Mieghem Journal: Catheter Cardiovasc Interv Date: 2021-02-03 Impact factor: 2.585
Authors: Rutger-Jan Nuis; David Wood; Herbert Kroon; Maarten van Wiechen; Darra Bigelow; Chris Buller; Joost Daemen; Peter de Jaegere; Zvonimir Krajcer; John Webb; Nicolas Van Mieghem Journal: Data Brief Date: 2021-03-18
Authors: Gregor Heitzinger; Christina Brunner; Sophia Koschatko; Varius Dannenberg; Katharina Mascherbauer; Kseniya Halavina; Carolina Doná; Matthias Koschutnik; Georg Spinka; Christian Nitsche; Markus Mach; Martin Andreas; Florian Wolf; Christian Loewe; Christoph Neumayer; Michael Gschwandtner; Andrea Willfort-Ehringer; Max-Paul Winter; Irene M Lang; Philipp E Bartko; Christian Hengstenberg; Georg Goliasch Journal: Front Cardiovasc Med Date: 2022-01-21