| Literature DB >> 31269651 |
Tharsini Sivapalan1, Antonietta Melchini1, Jack Coode-Bate1,2, Paul W Needs1, Richard F Mithen1, Shikha Saha3.
Abstract
This is the first report describing an analytical method for quantitative analysis of two naturally occurring sulphur compounds, S-methyl-l-cysteine (SMC) and S-methyl-l-cysteine sulfoxide (SMCSO), in human body fluids using isotope-labelled internal standards and liquid chromatography-mass spectrometry (LC-MS)/MS techniques. This method was validated according to the guideline of the Royal Society of Chemistry Analytical Methods Committee. It offers significant advantages including simple and fast preparation of human biological samples. The limits of detection of SMC were 0.08 µM for urine and 0.04 µM for plasma. The limits of detection of SMCSO were 0.03 µM for urine and 0.02 µM for plasma. The calibration curves of all matrices showed linearity with correlation coefficients r2 > 0.9987. The intra and inter day precisions in three levels of known concentrations were >10% and >20%, respectively. The quantification accuracy was 98.28 ± 5.66%. The proposed method would be beneficial for the rapid and accurate determination of the SMC and SMCSO in human plasma and urine samples using by isotope labelled internal standards.Entities:
Keywords: S-methyl-l-cysteine; S-methyl-l-cysteine sulfoxide; body fluids; liquid chromatography tandem mass spectrometry; sulphur compounds
Year: 2019 PMID: 31269651 PMCID: PMC6651111 DOI: 10.3390/molecules24132427
Source DB: PubMed Journal: Molecules ISSN: 1420-3049 Impact factor: 4.411
Figure 1Structures of internal standards (a) 34S-Trideuteromethylcysteine (34S-d3SMC) and (b) 34S-trideuteromethylcysteine sulfoxide (34S-d3SMCSO).
Liquid chromatography-mass spectrometry (LC-MS)/MS parameters of S-methyl-l-cysteine sulfoxide (SMCSO).
| Analyte | Retention Time (mins) | Precursor Ion ( | Product Ion ( | Collision Energy | Cell Accelerator Energy | Polarity |
|---|---|---|---|---|---|---|
| SMCSO | 2.6 | 152.19 | 87.9 | 4 | 4 | Positive |
| SMCSO | 2.6 | 152.19 | 69.9 | 16 | 4 | Positive |
| SMCSO | 2.6 | 152.19 | 42.1 | 20 | 4 | Positive |
| SMC | 2.7 | 136.19 | 119.1 | 10 | 4 | Positive |
| SMC | 2.7 | 136.19 | 47 | 34 | 4 | Positive |
| 34 | 2.6 | 157.05 | 87.9 | 8 | 4 | Positive |
| 34 | 2.6 | 157.05 | 42.1 | 28 | 4 | Positive |
| 34 | 2.7 | 141.06 | 124 | 10 | 4 | Positive |
| 34 | 2.7 | 141.06 | 42.1 | 30 | 4 | Positive |
Validation data in human plasma and urine.
| Analyte | R2 | Precision (n = 5) | Precision (n = 5) | Accuracy | LOD | LOQ | ||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|
| L | M | H | L | M | H | L | M | H | ||||
| SMC (Urine) | 0.9998 | 9.44 | 2.00 | 5.13 | 9.19 | 8.17 | 5.28 | 82.8 | 101 | 101 | 0.08 | 0.24 |
| SMC (Plasma) | 0.9987 | 8.8 | 6.8 | 7.2 | 11.29 | 7.81 | 7.16 | 97.7 | 97.0 | 95.49 | 0.04 | 0.12 |
| SMCSO (Urine) | 0.9995 | 5.49 | 5.14 | 5.43 | 14.36 | 7.11 | 5.50 | 100.4 | 105.98 | 101.2 | 0.03 | 0.09 |
| SMCSO (Plasma) | 0.9989 | 8.86 | 2.1 | 4.8 | 19.80 | 10.69 | 6.72 | 99.64 | 99.38 | 97.77 | 0.02 | 0.06 |
Figure 2LC-MS/MS chromatograms of S-methyl-l-cysteine (SMC) and SMCSO in human urine. (a) SMC authentic standard in human urine; (b) SMCSO authentic standard spiked in human urine; (c) SMC detected in human urine; (d) SMCSO detected in human urine; (e) 34S-d3SMC internal standard in urine; (f) 34S-d3SMCSO internal standard in urine.
Figure 3LC-MS/MS chromatograms of SMC and SMCSO in human plasma. (a) SMC authentic standard spiked in human plasma; (b) SMCSO authentic standard spiked in human plasma; (c) SMC detected in human plasma; (d) SMCSO detected in human plasma; (e) 34S-d3SMC internal standard in plasma; (f) 34S-d3SMCSO internal standard in plasma.