Nicolas Dumonteil1, Christian Terkelsen2, Christian Frerker3, Frederic Collart4, Jochen Wöhrle5, Christian Butter6, Tomas Hovorka7, Frederic Pinaud8, Helmut Baumgartner9, Giuseppe Tarantini10, Olaf Wendler11, Thierry Lefèvre12. 1. Groupe CardioVasculaire Interventionnel (GCVI), Clinique Pasteur, Toulouse, France. Electronic address: ndumonteil@clinique-pasteur.com. 2. Aarhus University Hospital, Skejby, Denmark. 3. Asklepios Clinic, Hamburg, Germany. 4. University Hospital La Timone, Marseille, France. 5. Department of Internal Medicine II - Cardiology, University Hospital of Ulm, Ulm, Germany. 6. Herzzentrum Brandenburg, Bernau, Germany. 7. Edwards Lifesciences, Prague, Czech Republic. 8. University Hospital, Angers, France. 9. University Hospital, Münster, Germany. 10. Padova Hospital, Italy. 11. King's College Hospital London, United Kingdom. 12. Private Hospital Jacques Cartier, Massy, France.
Abstract
AIMS: To investigate the impact of transcatheter aortic valve replacement (TAVR) without preliminary balloon aortic valvuloplasty (pre-BAV) on periprocedural outcomes in a large, real-world registry. METHODS AND RESULTS: The SOURCE 3 registry was an observational, multi-center, single-arm study of patients with severe, symptomatic aortic stenosis at high surgical risk treated with the SAPIEN 3 transcatheter heart valve (THV). Procedural and 30-day outcomes were compared between two groups of 772 patients each (retrospectively matched) with or without pre-BAV. All baseline clinical, echocardiographic, and anatomical valve characteristics were comparable between groups except for Society of Thoracic Surgeons (STS) score, which was lower in the direct TAVR group (6.0 ± 5.9 vs 7.8 ± 8.3; p = 0.003). In the direct TAVR group, there were less post-dilatations (8.1% vs. 13.1%, p = 0.002), shorter procedural time (70.9 ± 39.8 min vs 73.0 ± 32.2 min, p = 0.033) and fluoroscopy time (13.4 ± 7.0 min vs 14.9 ± 7.4 min, p < 0.001). Other procedural outcomes and echocardiographic variables at 30 days did not differ significantly between the two groups: safety endpoint (10.4% with pre-BAV vs 13.5% with direct TAVR, p = 0.059), mortality (2.1% vs 2.3%, p = 0.730), disabling strokes (0.4% vs 0.5%, p = 0.704), and moderate to severe paravalvular leak (PVL) (3.2% vs 2.2%, p = 0.40). Unexpectedly, new permanent pacemaker implantation and life-threatening bleeds were less frequently observed with pre-BAV group than with direct TAVR (10.4% vs 13.9%, p = 0.032 and 3.5% vs 6.5%, p = 0.007, respectively). CONCLUSION: In this large TAVR dataset, direct implantation of the SAPIEN 3 THV without pre-BAV was feasible and safe and resulted in shorter procedures, without impact on 30-day prosthesis function and PVL.
AIMS: To investigate the impact of transcatheter aortic valve replacement (TAVR) without preliminary balloon aortic valvuloplasty (pre-BAV) on periprocedural outcomes in a large, real-world registry. METHODS AND RESULTS: The SOURCE 3 registry was an observational, multi-center, single-arm study of patients with severe, symptomatic aortic stenosis at high surgical risk treated with the SAPIEN 3 transcatheter heart valve (THV). Procedural and 30-day outcomes were compared between two groups of 772 patients each (retrospectively matched) with or without pre-BAV. All baseline clinical, echocardiographic, and anatomical valve characteristics were comparable between groups except for Society of Thoracic Surgeons (STS) score, which was lower in the direct TAVR group (6.0 ± 5.9 vs 7.8 ± 8.3; p = 0.003). In the direct TAVR group, there were less post-dilatations (8.1% vs. 13.1%, p = 0.002), shorter procedural time (70.9 ± 39.8 min vs 73.0 ± 32.2 min, p = 0.033) and fluoroscopy time (13.4 ± 7.0 min vs 14.9 ± 7.4 min, p < 0.001). Other procedural outcomes and echocardiographic variables at 30 days did not differ significantly between the two groups: safety endpoint (10.4% with pre-BAV vs 13.5% with direct TAVR, p = 0.059), mortality (2.1% vs 2.3%, p = 0.730), disabling strokes (0.4% vs 0.5%, p = 0.704), and moderate to severe paravalvular leak (PVL) (3.2% vs 2.2%, p = 0.40). Unexpectedly, new permanent pacemaker implantation and life-threatening bleeds were less frequently observed with pre-BAV group than with direct TAVR (10.4% vs 13.9%, p = 0.032 and 3.5% vs 6.5%, p = 0.007, respectively). CONCLUSION: In this large TAVR dataset, direct implantation of the SAPIEN 3 THV without pre-BAV was feasible and safe and resulted in shorter procedures, without impact on 30-day prosthesis function and PVL.
Authors: Alberto Alperi; Guillem Muntané-Carol; Afonso B Freitas-Ferraz; Lucia Junquera; David Del Val; Laurent Faroux; François Philippon; Josep Rodés-Cabau Journal: Ann Cardiothorac Surg Date: 2020-11
Authors: Gerhard Schymik; Tanja Rudolph; Claudius Jacobshagen; Jürgen Rothe; Hendrik Treede; Sebastian Kerber; Derk Frank; Lenka Sykorova; Maki Okamoto; Martin Thoenes; Cornelia Deutsch; Peter Bramlage; Christian Butter Journal: Open Heart Date: 2019-10-03