Time-dependent surgical instrument contamination begins earlier in the uncovered table than in the covered table.

Erdal Uzun1, Abdulhamit Misir2, Mustafa Ozcamdalli3, Emine Eylul Kizkapan4, Alper Cirakli1, Mustafa Kerem Calgin5.   

Abstract

PURPOSE: Time-dependent surgical instrument contamination and the effect of covering during arthroplasty have not been investigated. This study aimed to evaluate time-dependent contamination of surgical instruments and the effect of covering on contamination as well as to perform bacterial typing of contaminated samples. The hypothesis was that covering the surgical instruments would decrease contamination rates.
METHODS: Sixty patients who underwent total knee arthroplasty were randomized and divided into two groups: surgical instruments covered with a sterile towel or surgical instruments left uncovered. K-wires were used to extract microbiological samples. The K-wires were placed in a liquid culture medium at 0, 15, 30, 60, 90, and 120 min. After 24-h incubation period, samples from liquid cultures were cultured on blood agar using swabs. Samples with growth after 48 h were considered contaminated. Microscopic, staining, and biochemical properties were used for bacterial typing.
RESULTS: Bacterial growth started after 30 and 60 min in the uncovered and covered groups, respectively. An increase in the number of K-wires contaminated with time was detected. At least 10,000 CFU/mL bacterial load was observed in the culture samples. Contamination was more significant in the uncovered group. A statistically significant difference in contamination was found between the uncovered and covered groups at 30-, 60-, 90-, and 120 min (p = 0.035, p = 0.012, p = 0.024, and p = 0.037, respectively). The most common bacteria on the contaminated instruments were coagulase-negative Staphylococci (60.4%), Staphylococcus aureus (22.9%), and Streptococcus agalactia (16.7%), respectively.
CONCLUSION: The risk of contamination increases with time. However, it may decrease if surgical instruments are covered. In the clinical practice, empiric antibiotic regimens based on the type of identified microorganisms in this study may be developed for postoperative periprosthetic joint infection prophylaxis. LEVEL OF EVIDENCE: Prognostic, Level II.

Entities:  

Keywords:  Contamination; Covering; Instrument; Periprosthetic joint infection; Total knee arthroplasty; Typing

Year:  2019        PMID: 31256214     DOI: 10.1007/s00167-019-05607-y

Source DB:  PubMed          Journal:  Knee Surg Sports Traumatol Arthrosc        ISSN: 0942-2056            Impact factor:   4.342


  4 in total

1.  Allograft contamination during suture preparation for anterior cruciate ligament reconstruction: an ex vivo study.

Authors:  Chenliang Wu; Xiuyuan Zhang; Yi Qiao; Jiebo Chen; Wei Su; Junjie Xu; Zipeng Ye; Jia Jiang; Caiqi Xu; Guoming Xie; Jinzhong Zhao; Song Zhao
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2022-02-23       Impact factor: 4.342

2.  Instrument tables equipped with local unidirectional airflow units reduce bacterial contamination during orthopedic implant surgery in an operating room with a displacement ventilation system.

Authors:  Josefin Seth Caous; Karin Svensson Malchau; Max Petzold; Ylva Fridell; Henrik Malchau; Linda Ahlstrom; Peter Grant; Annette Erichsen Andersson
Journal:  Infect Prev Pract       Date:  2022-05-26

3.  The safety of a novel single-drape cover for sterile back tables in the operating room compared to the standard two-drape method: an experimental study.

Authors:  Mohammadreza Zarei; Saeed Babajani-Vafsi; Mohammad Hassan Kazemi-Galougahi; Ashraf Bakhshi; Neda Mirbagher Ajorpaz; Mahdi Ghorbani
Journal:  Patient Saf Surg       Date:  2022-06-02

4.  Implant contamination as a cause of surgical site infection in spinal surgery: are single-use implants a reasonable solution? - a systematic review.

Authors:  Friederike Schömig; Carsten Perka; Matthias Pumberger; Rudolf Ascherl
Journal:  BMC Musculoskelet Disord       Date:  2020-09-25       Impact factor: 2.362

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.