Effect of a femoral head prosthesis on megavoltage beam radiotherapy.

P J Biggs1, M D Russell.   

Abstract

A few patients undergoing pelvic irradiation present with a prosthetic hip. The presence of this metal object often interferes with the lateral treatment fields if a four-field box irradiation technique is used. Measurements of the effect such a prosthesis may have on the dose delivered to the pelvis for beams of 60Co gamma rays and 10 MV and 25 MV X-rays, as a function of field size and depth have been made. The results show a strong variation in the dose behind the prosthesis depending on the position of the measurement, with little or no increase through the center of the head or ball, but a sharp drop either around its circumference or along the stem of the prosthesis. Measurements made with ionization chambers through the head of the prosthesis indicate an average dose decrease of approximately 2% for 25 MV X rays and average increases of approximately 2% for 10 MV X rays and 5% for 60Co. There is little variation with field size and depth except close to the prosthesis, at 25 MV. Measurements also indicate an increase in dose close to the upstream surface of the prosthesis at all energies, but in the downstream direction, only the data at 25 MV shows an increase.

Entities:  

Mesh:

Substances:

Year:  1988        PMID: 3125136     DOI: 10.1016/0360-3016(88)90279-9

Source DB:  PubMed          Journal:  Int J Radiat Oncol Biol Phys        ISSN: 0360-3016            Impact factor:   7.038


  4 in total

1.  Dose attenuation effect of hip prostheses in a 9-MV photon beam: commercial treatment planning system versus Monte Carlo calculations.

Authors:  Asghar Mesbahi; Farshad Seyed Nejad
Journal:  Radiat Med       Date:  2007-12-25

2.  Dose comparison between Gafchromic film, XiO, and Monaco treatment planning systems in a novel pelvic phantom that contains a titanium hip prosthesis.

Authors:  Nicholas Ade; F C P du Plessis
Journal:  J Appl Clin Med Phys       Date:  2017-07-25       Impact factor: 2.102

3.  Study of dosimetric properties of flattened and unflattened megavoltage x ray beam on high Z implant materials.

Authors:  Tamilarasan Rajamanickam; Sivakumar Muthu; Perumal Murugan; Muddappa Pathokonda; Krishnamoorthy Senthilnathan; Narayanasamy Arunai Nambi Raj; Padmanabhan Ramesh Babu
Journal:  J Appl Clin Med Phys       Date:  2018-09-28       Impact factor: 2.102

4.  Dose uncertainties associated with a set density override of unknown hip prosthetic composition.

Authors:  James D Rijken; Christopher J Colyer
Journal:  J Appl Clin Med Phys       Date:  2017-08-30       Impact factor: 2.102

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.