MeV-SIMS TOF Imaging of Organic Tissue with Continuous Primary Beam.

Boštjan Jenčič1, Primož Vavpetič1, Mitja Kelemen1, Matjaž Vencelj1, Katarina Vogel-Mikuš1,2, Anja Kavčič2, Primož Pelicon3.   

Abstract

MeV-SIMS is an emerging mass spectrometry imaging method, which utilizes fast, heavy ions to desorb secondary molecules. High yields and low fragmentation rates of large molecules, associated with the electronic sputtering process, make it particularly useful in biomedical research, where insight into distribution of organic molecules is needed. Since the implementation of MeV-SIMS in to the micro-beam line at the tandem accelerator of Jožef Stefan Institute, MeV-SIMS provided some valuable observations on the distribution of biomolecules in plant tissue, as discussed by Jenčič et al. (Nucl. Inst. Methods Phys. Res. B. 371, 205-210, 2016; Nucl. Inst. Methods Phys. Res. B. 404, 140-145, 2017). However, limited focusing ability of the chlorine ion beam only allowed imaging at the tissue level. In order to surpass shortcomings of the existing method, we introduced a new approach, where we employ a continuous, low-current primary beam. In this mode, we bombard thin samples with a steady chlorine ion flux of approx. 5000 ions/s. After desorbing molecules, chlorine ions penetrate through the thinly cut sample and trigger the time-of-flight "start" signal on a continuous electron multiplier detector, positioned behind the sample. Such bombardment is more effective than previously used pulsing-beam mode, which demanded several orders of magnitude higher primary ion beam currents. Sub-micrometer focusing of low-current primary ion beam allows imaging of biological tissue on a subcellular scale. Simultaneously, new time-of-flight acquisition approach also improves mass resolution by a factor of 5. Within the article, we compare the performance of both methods and demonstrate the application of continuous mode on biological tissue. We also describe the thin sample preparation protocol, necessary for measurements with low primary ion currents.

Entities:  

Keywords:  Electronic sputtering; Imaging mass spectrometry; MeV-SIMS; Molecular imaging; Time-of-flight

Year:  2019        PMID: 31250317     DOI: 10.1007/s13361-019-02258-8

Source DB:  PubMed          Journal:  J Am Soc Mass Spectrom        ISSN: 1044-0305            Impact factor:   3.109


  3 in total

1.  Depth profiling of Cr-ITO dual-layer sample with secondary ion mass spectrometry using MeV ions in the low energy region.

Authors:  Marko Barac; Marko Brajković; Zdravko Siketić; Jernej Ekar; Iva Bogdanović Radović; Iva Šrut Rakić; Janez Kovač
Journal:  Sci Rep       Date:  2022-07-08       Impact factor: 4.996

2.  ToF-SIMS Depth Profiling of Metal, Metal Oxide, and Alloy Multilayers in Atmospheres of H2, C2H2, CO, and O2.

Authors:  Jernej Ekar; Peter Panjan; Sandra Drev; Janez Kovač
Journal:  J Am Soc Mass Spectrom       Date:  2021-12-22       Impact factor: 3.109

3.  Molecular imaging of humain hair with MeV-SIMS: A case study of cocaine detection and distribution in the hair of a cocaine user.

Authors:  Luka Jeromel; Nina Ogrinc; Zdravko Siketić; Primož Vavpetič; Zdravko Rupnik; Klemen Bučar; Boštjan Jenčič; Mitja Kelemen; Matjaž Vencelj; Katarina Vogel-Mikuš; Janez Kovač; Ron M A Heeren; Bryn Flinders; Eva Cuypers; Žiga Barba; Primož Pelicon
Journal:  PLoS One       Date:  2022-03-25       Impact factor: 3.240

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.