Literature DB >> 31244918

Integrating 3D Cell Culture of PC12 Cells with Microchip-Based Electrochemical Detection.

Benjamin T Mehl1, R Scott Martin1.   

Abstract

Developing in vitro cell culture models that accurately mimic in vivo processes in a manner that also enables near real-time analysis of neurotransmitters is an important research area. New technologies being developed such as 3D scaffolds for cell culture and 3D printed microfluidics provide an opportunity for such advancements. In this work, PC12 cells were used as a model system and they were immobilized onto a 3D scaffold of polystyrene (PS) fibers. These fibers were created by electrospinning onto PS sheets, which were laser cut and, after cell seeding, inserted into a 3D printed microfluidic device. The 3D printed device was designed with threads for connecting commercial fittings (to integrate automated pumps and a 4-port injection system) and a steel pin for simple coupling with PDMS/polystyrene analytical devices. A straight PDMS channel was used for simple (and continuous) flow-based detection by sealing onto a PS base containing an embedded gold array working electrode and a platinum pseudo-reference. Electrochemical detection of stimulated catecholamine release was demonstrated. The insert-based system was then integrated with a bilayer valving PDMS device (for microchip electrophoresis) sealed onto a PS base (with electrodes for electrochemical detection). This base was embedded with a Pd decoupler (for grounding the separation voltage and adsorbing hydrogen) and a 33 µm carbon fiber working electrode for in-channel detection. PC12 cells were stimulated in the 3D cell culture device, and the valving/electrophoresis microchip was able to separate and detect dopamine and norepinephrine release. This work demonstrates the ability to integrate 3D cell scaffolds with microchip-based analysis for detection of multiple analytes released from cells.

Entities:  

Year:  2019        PMID: 31244918      PMCID: PMC6594695          DOI: 10.1039/C8AY02672F

Source DB:  PubMed          Journal:  Anal Methods        ISSN: 1759-9660            Impact factor:   2.896


  44 in total

1.  Investigation of the mechanism of pH-mediated stacking of anions for the analysis of physiological samples by capillary electrophoresis.

Authors:  Stacy D Arnett; Craig E Lunte
Journal:  Electrophoresis       Date:  2003-06       Impact factor: 3.535

2.  Overoxidation of carbon-fiber microelectrodes enhances dopamine adsorption and increases sensitivity.

Authors:  Michael L A V Heien; Paul E M Phillips; Garret D Stuber; Andrew T Seipel; R Mark Wightman
Journal:  Analyst       Date:  2003-11-11       Impact factor: 4.616

3.  pH-mediated acid stacking with reverse pressure for the analysis of cationic pharmaceuticals in capillary electrophoresis.

Authors:  Julie A Gillogly; Craig E Lunte
Journal:  Electrophoresis       Date:  2005-02       Impact factor: 3.535

4.  Use of micromolded carbon dual electrodes with a palladium decoupler for amperometric detection in microchip electrophoresis.

Authors:  Laura C Mecker; R Scott Martin
Journal:  Electrophoresis       Date:  2006-12       Impact factor: 3.535

Review 5.  The PC12 cell as model for neurosecretion.

Authors:  R H S Westerink; A G Ewing
Journal:  Acta Physiol (Oxf)       Date:  2007-11-15       Impact factor: 6.311

6.  Voltammetric and pharmacological characterization of dopamine release from single exocytotic events at rat pheochromocytoma (PC12) cells.

Authors:  K D Kozminski; D A Gutman; V Davila; D Sulzer; A G Ewing
Journal:  Anal Chem       Date:  1998-08-01       Impact factor: 6.986

7.  Effect of fiber diameter on spreading, proliferation, and differentiation of osteoblastic cells on electrospun poly(lactic acid) substrates.

Authors:  Anand S Badami; Michelle R Kreke; M Shane Thompson; Judy S Riffle; Aaron S Goldstein
Journal:  Biomaterials       Date:  2005-07-15       Impact factor: 12.479

8.  DNA fluorometric assay in 96-well tissue culture plates using Hoechst 33258 after cell lysis by freezing in distilled water.

Authors:  R Rago; J Mitchen; G Wilding
Journal:  Anal Biochem       Date:  1990-11-15       Impact factor: 3.365

9.  Integration of continuous-flow sampling with microchip electrophoresis using poly(dimethylsiloxane)-based valves in a reversibly sealed device.

Authors:  Michelle W Li; R Scott Martin
Journal:  Electrophoresis       Date:  2007-07       Impact factor: 3.535

10.  Stable gene silencing of synaptotagmin I in rat PC12 cells inhibits Ca2+-evoked release of catecholamine.

Authors:  Johnnie M Moore; Jason B Papke; Anne L Cahill; Amy B Harkins
Journal:  Am J Physiol Cell Physiol       Date:  2006-02-08       Impact factor: 4.249

View more
  7 in total

Review 1.  Biological applications of microchip electrophoresis with amperometric detection: in vivo monitoring and cell analysis.

Authors:  Kelci M Schilly; Shamal M Gunawardhana; Manjula B Wijesinghe; Susan M Lunte
Journal:  Anal Bioanal Chem       Date:  2020-04-28       Impact factor: 4.142

2.  Review of 3D Cell Culture with Analysis in Microfluidic Systems.

Authors:  Andre D Castiaux; Dana M Spence; R Scott Martin
Journal:  Anal Methods       Date:  2019-08-06       Impact factor: 2.896

3.  A Hybrid Nanofiber/Paper Cell Culture Platform for Building a 3D Blood-brain Barrier Model.

Authors:  Kaixiang Huang; Andre Castiaux; Ram Podicheti; Douglas B Rusch; R Scott Martin; Lane A Baker
Journal:  Small Methods       Date:  2021-08-16

4.  Direct embedding and versatile placement of electrodes in 3D printed microfluidic-devices.

Authors:  Andre D Castiaux; Emily R Currens; R Scott Martin
Journal:  Analyst       Date:  2020-04-03       Impact factor: 4.616

5.  3D-Printed Microfluidic Device with In-line Amperometric Detection that Also Enables Multi-Modal Detection.

Authors:  Elizabeth A Hayter; Andre D Castiaux; R Scott Martin
Journal:  Anal Methods       Date:  2020-03-27       Impact factor: 2.896

Review 6.  Recent innovations in cost-effective polymer and paper hybrid microfluidic devices.

Authors:  Wan Zhou; Maowei Dou; Sanjay S Timilsina; Feng Xu; XiuJun Li
Journal:  Lab Chip       Date:  2021-07-13       Impact factor: 7.517

Review 7.  Surface Modification Techniques for Endothelial Cell Seeding in PDMS Microfluidic Devices.

Authors:  Fahima Akther; Shazwani Binte Yakob; Nam-Trung Nguyen; Hang T Ta
Journal:  Biosensors (Basel)       Date:  2020-11-19
  7 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.