Use of micromolded carbon dual electrodes with a palladium decoupler for amperometric detection in microchip electrophoresis.

Laura C Mecker1, R Scott Martin.   

Abstract

The fabrication and evaluation of micromolded dual carbon ink electrodes and their integration with a fabricated palladium decoupler for use in microchip electrophoresis is described. As opposed to previous work involving carbon-based dual electrodes with microchip electrophoresis, this approach results in electrodes that are amenable to mass production in a manner where the decoupler/electrode alignment is fixed and reproducible. In this work, electrode sizes and spacings were optimized to result in dual carbon electrodes that are 1 microm in height and separated by 100 microm. Fluorescence microscopy was used to investigate leakage around the electrode/channel interface as well as to investigate what effect the dual electrodes have on band broadening phenomena. The performance of the microelectrodes was demonstrated by the separation and selective dual electrode detection of neurotransmitters in the presence of ascorbic acid. It was also found that addition of SDS to the buffer system improved both the LODs and collection efficiencies. This approach, which is the first involving carbon-based dual electrodes with an on-chip palladium decoupler, will be useful for separating and detecting neurotransmitters that are either collected by in vivo sampling or released from cells on-chip.

Entities:  

Mesh:

Substances:

Year:  2006        PMID: 17096314     DOI: 10.1002/elps.200600401

Source DB:  PubMed          Journal:  Electrophoresis        ISSN: 0173-0835            Impact factor:   3.535


  23 in total

1.  Use of Recordable Compact Discs to Fabricate Electrodes for Microchip-based Analysis Systems.

Authors:  Douglas C Kirkpatrick; Christiana Antwi; R Scott Martin
Journal:  Anal Methods       Date:  2010-07-01       Impact factor: 2.896

2.  Coupling Microdialysis Sampling to Microchip Electrophoresis in a Reversibly Sealed Device.

Authors:  Laura C Mecker; R Scott Martin
Journal:  JALA Charlottesv Va       Date:  2007-10

3.  Use of a Carbon-ink Microelectrode Array for Signal Enhancement in Microchip Electrophoresis with Electrochemical Detection.

Authors:  Laura C Mecker; Laura A Filla; R Scott Martin
Journal:  Electroanalysis       Date:  2010-10-01       Impact factor: 3.223

4.  Integration of microchip electrophoresis with electrochemical detection using an epoxy-based molding method to embed multiple electrode materials.

Authors:  Alicia S Johnson; Asmira Selimovic; R Scott Martin
Journal:  Electrophoresis       Date:  2011-10-31       Impact factor: 3.535

Review 5.  Biological applications of microchip electrophoresis with amperometric detection: in vivo monitoring and cell analysis.

Authors:  Kelci M Schilly; Shamal M Gunawardhana; Manjula B Wijesinghe; Susan M Lunte
Journal:  Anal Bioanal Chem       Date:  2020-04-28       Impact factor: 4.142

Review 6.  Use of epoxy-embedded electrodes to integrate electrochemical detection with microchip-based analysis systems.

Authors:  Asmira Selimovic; Alicia S Johnson; István Z Kiss; R Scott Martin
Journal:  Electrophoresis       Date:  2011-03-17       Impact factor: 3.535

7.  Electrochemical Oscillations of Nickel Electrodissolution in an Epoxy-Based Microchip Flow Cell.

Authors:  Alexander G Cioffi; R Scott Martin; István Z Kiss
Journal:  J Electroanal Chem (Lausanne)       Date:  2011-08-01       Impact factor: 4.464

8.  Microchip-based integration of cell immobilization, electrophoresis, post-column derivatization, and fluorescence detection for monitoring the release of dopamine from PC 12 cells.

Authors:  Michelle W Li; R Scott Martin
Journal:  Analyst       Date:  2008-07-08       Impact factor: 4.616

9.  Encapsulated electrodes for microchip devices: microarrays and platinized electrodes for signal enhancement.

Authors:  Asmira Selimovic; R Scott Martin
Journal:  Electrophoresis       Date:  2013-07       Impact factor: 3.535

10.  A parallel dual-electrode detector for capillary electrophoresis.

Authors:  Megan K Dorris; Eric W Crick; Craig E Lunte
Journal:  Electrophoresis       Date:  2012-09       Impact factor: 3.535

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.