Literature DB >> 31240328

Texture analysis of placental MRI: can it aid in the prenatal diagnosis of placenta accreta spectrum?

Eric Chen1, Winnie A Mar2, Jeanne M Horowitz3, Amanda Allen4, Priyanka Jha5, Donald R Cantrell3, Kejia Cai4.   

Abstract

PURPOSE: To determine if texture analysis can differentiate placenta accreta spectrum (PAS) from normal placenta on MRI.
METHODS: We performed retrospective image analysis of 80 patients, comprised of 46 patients with PAS and 34 patients without PAS. Histopathology was used as the reference standard. Sagittal single shot fast spin echo T2-weighted MRI sequences acquired from a single institution were analyzed. Placental heterogeneity was quantified using in-house software on a Matlab platform, including the standard deviation of pixel intensity, coefficient of variation, gray-level co-occurrence matrices (GLCM), histogram-oriented gradients (HOG), and fractal analysis with box sizes from 2 to 512. Two-tailed unpaired Student's t test was used with statistical significance of p < 0.05.
RESULTS: PAS was associated with higher values for standard deviation of pixel intensity and fractal analysis at every box size. Fractal analysis at box sizes 256 (p = 0.011) and 32 (p = 0.021), and standard deviation of pixel intensity (p = 0.023) were the most statistically significant. Fractal values at box size 256 for PAS was 0.13 versus 0.090 for patients without PAS, while standard deviation of pixel intensity was 3.7 for PAS versus 2.5 for patients without PAS. No statistically significant association between PAS and GLCM, coefficient of variation, and HOG was found.
CONCLUSION: Statistically significant differences were found between normal and abnormal groups using standard deviation of pixel intensity and fractal analysis.

Entities:  

Keywords:  Fractal analysis; MRI; Placenta accreta; Placenta accreta spectrum; Texture analysis

Year:  2019        PMID: 31240328     DOI: 10.1007/s00261-019-02104-1

Source DB:  PubMed          Journal:  Abdom Radiol (NY)


  4 in total

1.  Prognosticators of intravoxel incoherent motion (IVIM) MRI for adverse maternal and neonatal clinical outcomes in patients with placenta accreta spectrum disorders.

Authors:  Tao Lu; Bin Song; Hong Pu; Kui-De Li; Meng-Wei Huang; Jie Mei; Shao-Yu Wang
Journal:  Transl Androl Urol       Date:  2020-04

2.  MRI-Based Radiomics Analysis for Intraoperative Risk Assessment in Gravid Patients at High Risk with Placenta Accreta Spectrum.

Authors:  Caiting Chu; Ming Liu; Yuzhen Zhang; Shuhui Zhao; Yaqiong Ge; Wenhua Li; Chengjin Gao
Journal:  Diagnostics (Basel)       Date:  2022-02-14

3.  Prenatal prediction and typing of placental invasion using MRI deep and radiomic features.

Authors:  Rongrong Xuan; Tao Li; Yutao Wang; Jian Xu; Wei Jin
Journal:  Biomed Eng Online       Date:  2021-06-05       Impact factor: 2.819

4.  Can introvoxel incoherent motion MRI be used to differentiate patients with placenta accreta spectrum disorders?

Authors:  Tao Lu; Hong Pu; Kui-de Li; Jie Mei; Meng-Wei Huang; Shao-Yu Wang
Journal:  BMC Pregnancy Childbirth       Date:  2019-12-30       Impact factor: 3.007

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.