Literature DB >> 31236730

Accuracy and reliability of continuous blood glucose monitoring during pediatric cardiopulmonary bypass.

Shinji Kawahito1, Naoji Mita2, Tomohiro Soga3, Shusuke Yagi3, Nami Kakuta2, Shiho Satomi2, Hiroyuki Kinoshita4, Kazumi Takaishi5, Tetsuya Kitagawa6, Hiroshi Kitahata5.   

Abstract

The purpose of this study was to assess the accuracy and reliability of a continuous blood glucose monitoring system (artificial endocrine pancreas; STG-55, Nikkiso, Tokyo, Japan) during pediatric cardiopulmonary bypass surgery. Twenty-five pediatric patients scheduled to undergo cardiovascular surgery with cardiopulmonary bypass (age 4 months to 11 years; body weight 5.6-59.7 kg) were enrolled. The glucose sensor line of the artificial endocrine pancreas was connected to the venous side of the cardiopulmonary bypass circuit and used for continuous blood glucose monitoring. We obtained 192 samples for blood gas assessment from the cardiopulmonary bypass circuit, and i-STAT (Abbott, East Windsor, NJ, USA) was used for conventional blood glucose assessment. The accuracies of continuous glucose measurements (STG-55) and conventional intermittent glucose measurements (i-STAT) during cardiopulmonary bypass were compared by means of Clarke error grid analysis. The results were divided into five zones, A, B, C, D, and E, and 78.6% of paired measurements were in zone A, while 21.4% were in zone B. We confirmed that the results of this continuous blood glucose monitoring system for cardiopulmonary bypass during pediatric cardiovascular surgery were highly reliable. An artificial endocrine pancreas may facilitate the safe use of intensive insulin therapy during pediatric cardiovascular surgery.

Entities:  

Keywords:  Artificial endocrine pancreas; Cardiopulmonary bypass; Continuous blood glucose monitoring; Intensive insulin therapy; Pediatric cardiovascular surgery

Mesh:

Substances:

Year:  2019        PMID: 31236730     DOI: 10.1007/s10047-019-01111-9

Source DB:  PubMed          Journal:  J Artif Organs        ISSN: 1434-7229            Impact factor:   1.731


  13 in total

1.  Intensive insulin therapy in critically ill patients.

Authors:  G van den Berghe; P Wouters; F Weekers; C Verwaest; F Bruyninckx; M Schetz; D Vlasselaers; P Ferdinande; P Lauwers; R Bouillon
Journal:  N Engl J Med       Date:  2001-11-08       Impact factor: 91.245

Review 2.  Intensive insulin therapy during cardiovascular surgery.

Authors:  Shinji Kawahito; Hiroshi Kitahata; Tetsuya Kitagawa; Shuzo Oshita
Journal:  J Med Invest       Date:  2010-08

3.  Association of hypoglycemia, hyperglycemia, and glucose variability with morbidity and death in the pediatric intensive care unit.

Authors:  Kupper A Wintergerst; Bruce Buckingham; Laura Gandrud; Becky J Wong; Saraswati Kache; Darrell M Wilson
Journal:  Pediatrics       Date:  2006-07       Impact factor: 7.124

4.  Evaluation of a novel artificial pancreas: closed loop glycemic control system with continuous blood glucose monitoring.

Authors:  Yuuki Tsukamoto; Yoshihiko Kinoshita; Hiroyuki Kitagawa; Masaya Munekage; Eri Munekage; Yuka Takezaki; Tomoaki Yatabe; Koichi Yamashita; Rie Yamazaki; Takehiro Okabayashi; Masatoshi Tarumi; Masaki Kobayashi; Suguru Mishina; Kazuhiro Hanazaki
Journal:  Artif Organs       Date:  2013-03-18       Impact factor: 3.094

5.  Evaluating clinical accuracy of systems for self-monitoring of blood glucose.

Authors:  W L Clarke; D Cox; L A Gonder-Frederick; W Carter; S L Pohl
Journal:  Diabetes Care       Date:  1987 Sep-Oct       Impact factor: 19.112

6.  Strict blood glucose control by an artificial endocrine pancreas during hepatectomy may prevent postoperative acute kidney injury.

Authors:  Naoji Mita; Shinji Kawahito; Tomohiro Soga; Kazumi Takaishi; Hiroshi Kitahata; Munehide Matsuhisa; Mitsuo Shimada; Hiroyuki Kinoshita; Yasuo M Tsutsumi; Katsuya Tanaka
Journal:  J Artif Organs       Date:  2016-08-24       Impact factor: 1.731

7.  Persistent hyperglycemia in critically ill children.

Authors:  Edward Vincent Faustino; Michael Apkon
Journal:  J Pediatr       Date:  2005-01       Impact factor: 4.406

8.  Intensive insulin therapy for patients in paediatric intensive care: a prospective, randomised controlled study.

Authors:  Dirk Vlasselaers; Ilse Milants; Lars Desmet; Pieter J Wouters; Ilse Vanhorebeek; Ingeborg van den Heuvel; Dieter Mesotten; Michael P Casaer; Geert Meyfroidt; Catherine Ingels; Jan Muller; Sophie Van Cromphaut; Miet Schetz; Greet Van den Berghe
Journal:  Lancet       Date:  2009-01-26       Impact factor: 79.321

9.  Analytical and pre-analytical performance characteristics of a novel cartridge-type blood gas analyzer for point-of-care and laboratory testing.

Authors:  Matthijs Oyaert; Tom Van Maerken; Silke Bridts; Silvi Van Loon; Heleen Laverge; Veronique Stove
Journal:  Clin Biochem       Date:  2018-01-12       Impact factor: 3.281

Review 10.  Problems associated with glucose toxicity: role of hyperglycemia-induced oxidative stress.

Authors:  Shinji Kawahito; Hiroshi Kitahata; Shuzo Oshita
Journal:  World J Gastroenterol       Date:  2009-09-07       Impact factor: 5.742

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.