Literature DB >> 27557726

Strict blood glucose control by an artificial endocrine pancreas during hepatectomy may prevent postoperative acute kidney injury.

Naoji Mita1, Shinji Kawahito2, Tomohiro Soga3, Kazumi Takaishi4, Hiroshi Kitahata4, Munehide Matsuhisa5, Mitsuo Shimada6, Hiroyuki Kinoshita7, Yasuo M Tsutsumi3, Katsuya Tanaka3.   

Abstract

The aim of the present study was to evaluate the usefulness of a closed-loop system (STG-55; Nikkiso, Tokyo, Japan), a type of artificial endocrine pancreas for the continuous monitoring and control of intraoperative blood glucose, for preventing postoperative acute kidney injury (AKI) in patients undergoing hepatectomy. Thirty-eight patients were enrolled in this study. Glucose concentrations were controlled with either a manual injection of insulin based on a commonly used sliding scale (manual insulin group, n = 19) or the programmed infusion of insulin determined by the control algorithm of the artificial endocrine pancreas (programmed insulin group, n = 19). After the induction of anesthesia, a 20-G intravenous catheter was inserted into the peripheral forearm vein of patients in the programmed insulin group and connected to an artificial endocrine pancreas (STG-55). The target range for glucose concentrations was set to 100-150 mg/dL. The mean serum creatinine concentrations of preoperative, postoperative 24 and 48 h were 0.72, 0.78, and 0.79 mg/dL in the programmed insulin group, and 0.81, 0.95, and 1.03 mg/dL in the manual insulin group, respectively. Elevations in serum creatinine concentrations postoperative 48 h were significantly suppressed in the programmed insulin group. The STG-55 closed-loop system was effective for maintaining strict blood glucose control during hepatectomy with minimal variability in blood glucose concentrations and for suppressing elevations in serum creatinine concentrations. Strict blood glucose control by an artificial endocrine pancreas during hepatectomy may prevent postoperative AKI.

Entities:  

Keywords:  Acute kidney injury; Artificial endocrine pancreas; Continuous blood glucose monitoring; Hepatectomy; Intensive insulin therapy

Mesh:

Substances:

Year:  2016        PMID: 27557726     DOI: 10.1007/s10047-016-0925-6

Source DB:  PubMed          Journal:  J Artif Organs        ISSN: 1434-7229            Impact factor:   1.731


  28 in total

1.  KDIGO clinical practice guidelines for acute kidney injury.

Authors:  Arif Khwaja
Journal:  Nephron Clin Pract       Date:  2012-08-07

2.  Evaluating clinical accuracy of systems for self-monitoring of blood glucose.

Authors:  W L Clarke; D Cox; L A Gonder-Frederick; W Carter; S L Pohl
Journal:  Diabetes Care       Date:  1987 Sep-Oct       Impact factor: 19.112

3.  Survival benefits of intensive insulin therapy in critical illness: impact of maintaining normoglycemia versus glycemia-independent actions of insulin.

Authors:  Björn Ellger; Yves Debaveye; Ilse Vanhorebeek; Lies Langouche; Annapaula Giulietti; Evelyne Van Etten; Paul Herijgers; Chantal Mathieu; Greet Van den Berghe
Journal:  Diabetes       Date:  2006-04       Impact factor: 9.461

4.  Continuous monitoring of glucose levels in the hepatic vein and systemic circulation during the Pringle maneuver in beagles.

Authors:  Tomoaki Yatabe; Hiroyuki Kitagawa; Takashi Kawano; Masaya Munekage; Takehiro Okabayashi; Koichi Yamashita; Kazuhiro Hanazaki; Masataka Yokoyama
Journal:  J Artif Organs       Date:  2011-05-28       Impact factor: 1.731

Review 5.  The not so 'mighty chondrion': emergence of renal diseases due to mitochondrial dysfunction.

Authors:  Andrew M Hall; Robert J Unwin
Journal:  Nephron Physiol       Date:  2006-11-08

Review 6.  The endothelial cell in ischemic acute kidney injury: implications for acute and chronic function.

Authors:  D P Basile
Journal:  Kidney Int       Date:  2007-05-02       Impact factor: 10.612

7.  Hyperglycemia during hepatic resection: continuous monitoring of blood glucose concentration.

Authors:  Hiromichi Maeda; Takehiro Okabayashi; Isao Nishimori; Koichi Yamashita; Takeki Sugimoto; Kazuhiro Hanazaki
Journal:  Am J Surg       Date:  2009-11-07       Impact factor: 2.565

8.  Intensive versus conventional insulin therapy: a randomized controlled trial in medical and surgical critically ill patients.

Authors:  Yaseen M Arabi; Ousama C Dabbagh; Hani M Tamim; Abdullah A Al-Shimemeri; Ziad A Memish; Samir H Haddad; Sofia J Syed; Hema R Giridhar; Asgar H Rishu; Mouhamad O Al-Daker; Salim H Kahoul; Riette J Britts; Maram H Sakkijha
Journal:  Crit Care Med       Date:  2008-12       Impact factor: 7.598

9.  Benefits and risks of tight glucose control in critically ill adults: a meta-analysis.

Authors:  Renda Soylemez Wiener; Daniel C Wiener; Robin J Larson
Journal:  JAMA       Date:  2008-08-27       Impact factor: 56.272

10.  Effect of intensive insulin therapy using a closed-loop glycemic control system in hepatic resection patients: a prospective randomized clinical trial.

Authors:  Takehiro Okabayashi; Isao Nishimori; Hiromichi Maeda; Koichi Yamashita; Tomoaki Yatabe; Kazuhiro Hanazaki
Journal:  Diabetes Care       Date:  2009-05-12       Impact factor: 19.112

View more
  5 in total

1.  Accuracy and reliability of continuous blood glucose monitoring during pediatric cardiopulmonary bypass.

Authors:  Shinji Kawahito; Naoji Mita; Tomohiro Soga; Shusuke Yagi; Nami Kakuta; Shiho Satomi; Hiroyuki Kinoshita; Kazumi Takaishi; Tetsuya Kitagawa; Hiroshi Kitahata
Journal:  J Artif Organs       Date:  2019-06-24       Impact factor: 1.731

2.  Impact of using a perioperative artificial endocrine pancreas in pancreatic resection.

Authors:  Toshiaki Yoshimoto; Tetsuya Ikemoto; Yuji Morine; Satoru Imura; Yu Saito; Shinichiro Yamada; Katsuki Miyazaki; Yukako Takehara; Mitsuo Shimada
Journal:  Ann Gastroenterol Surg       Date:  2020-07-18

Review 3.  Journal of Artificial Organs 2017: the year in review : Journal of Artificial Organs Editorial Committee.

Authors:  Y Sawa; G Matsumiya; K Matsuda; E Tatsumi; T Abe; K Fukunaga; S Ichiba; A Kishida; K Kokubo; T Masuzawa; A Myoui; M Nishimura; T Nishimura; T Nishinaka; E Okamoto; S Tokunaga; T Tomo; T Tsukiya; Y Yagi; T Yamaoka
Journal:  J Artif Organs       Date:  2018-02-09       Impact factor: 1.731

4.  Contribution of pancreatic α-cell function to insulin sensitivity and glycemic variability in patients with type 1 diabetes.

Authors:  Nobuyuki Takahashi; Daisuke Chujo; Hiroshi Kajio; Kohjiro Ueki
Journal:  J Diabetes Investig       Date:  2018-10-30       Impact factor: 4.232

5.  Intraoperative glycemic control in patients undergoing Orthotopic liver transplant: a single center prospective randomized study.

Authors:  Sathish S Kumar; Shawn J Pelletier; Amy Shanks; Aleda Thompson; Christopher J Sonnenday; Paul Picton
Journal:  BMC Anesthesiol       Date:  2020-01-04       Impact factor: 2.217

  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.