Literature DB >> 31228358

Outcomes of visual tooth shade selection performed by operators with different experience.

Begüm Yılmaz1, Özgür Irmak1, Batu Can Yaman1.   

Abstract

OBJECTIVE: To evaluate the effect of professional experience and lighting conditions on visual shade selection on natural teeth and comparing the visual-shade-selection results with those of instrumental methods.
MATERIALS AND METHODS: Shade selection was performed on five maxillary central incisors. The 25 observers were divided into five groups according to their professional experience. Observers performed visual-shade-selection using shade guide (Vita 3D Master, Vita Zahnfabrik, Bad Säckingen, Germany) under two lighting conditions (4000 and 6500 K) from the cervical, middle and incisal thirds of the teeth. Same teeth were measured using an intraoral scanner (Trios 3Shape, Copenhagen, Denmark) and spectrophotometer (Vita Easyshade Compact, Vita Zahnfabrik, Bad Säckingen, Germany), under the same two lighting conditions.
RESULTS: Visual-shade-selection outcomes were not affected by professional experience under both lighting conditions (P < .05). Outcomes of visual-shade-selection and intraoral scanner were not significantly different than that of spectrophotometer (P > .05). Lighting conditions had no effect on the shade measurement outcomes of visual shade selection, Vita Easyshade Compact, and Trios 3Shape (P > .05).
CONCLUSIONS: Shade measurement outcomes were not affected by the lighting conditions (4000 and 6500 K). The shade measurement feature of the T-3S could be an alternative to V-ES and VSS. CLINICAL SIGNIFICANCE: This study suggests professional experience and lighting conditions has no effect on visual shade selection. Trios 3Shape could be used for shade determination as an alternative to a Vita Easyshade Compact spectrophotometer.
© 2019 Wiley Periodicals, Inc.

Entities:  

Keywords:  operator experience; shade selection; spectrophotometer; tooth color; visual shade selection

Year:  2019        PMID: 31228358     DOI: 10.1111/jerd.12507

Source DB:  PubMed          Journal:  J Esthet Restor Dent        ISSN: 1496-4155            Impact factor:   2.843


  3 in total

1.  Evaluation of accuracy and characteristics of tooth-color matching by intraoral scanners based on Munsell color system: an in vivo study.

Authors:  Mingming Huang; Hongqiang Ye; Hu Chen; Yongsheng Zhou; Yunsong Liu; Yong Wang; Yuchun Sun
Journal:  Odontology       Date:  2022-02-25       Impact factor: 2.885

2.  Color stability of Lucirin-photo-activated resin composite after immersion in different staining solutions: a spectrophotometric study.

Authors:  Rasha AlSheikh
Journal:  Clin Cosmet Investig Dent       Date:  2019-09-05

3.  Spectrophotometric evaluation of restorative composite shades and their match with a classical shade guide.

Authors:  Rafael Melara; Luciana Mendonça; Fábio Herrmann Coelho-de-Souza; Juliana Nunes Rolla; Luciano de Souza Gonçalves
Journal:  Restor Dent Endod       Date:  2021-11-12
  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.