Ratio of Optic Nerve Sheath Diameter to Eyeball Transverse Diameter by Ultrasound Can Predict Intracranial Hypertension in Traumatic Brain Injury Patients: A Prospective Study.

Jie Du1, Yanjun Deng1, Hua Li1, Shigang Qiao1,2, Mengnan Yu1, Qingya Xu1, Chen Wang3,4.   

Abstract

BACKGROUND: Measuring optic nerve sheath diameter (ONSD), an indicator to predict intracranial hypertension, is noninvasive and convenient, but the reliability of ONSD needs to be improved. Instead of using ONSD alone, this study aimed to evaluate the reliability of the ratio of ONSD to eyeball transverse diameter (ONSD/ETD) in predicting intracranial hypertension in traumatic brain injury (TBI) patients.
METHODS: We performed a prospective study on patients admitted to the Surgery Intensive Care Unit. The included 52 adults underwent craniotomy for TBI between March 2017 and September 2018. The ONSD and ETD of each eyeball were measured by ultrasound and computed tomography (CT) scan within 24 h after a fiber optic probe was placed into lateral ventricle. Intracranial pressure (ICP) > 20 mmHg was regarded as intracranial hypertension. The correlations between invasive ICP and ultrasound-ONSD/ETD ratio, ultrasound-ONSD, CT-ONSD/ETD ratio, and CT-ONSD were each analyzed separately.
RESULTS: Ultrasound measurement was successfully performed in 94% (n = 49) of cases, and ultrasound and CT measurement were performed in 48% (n = 25) of cases. The correlation efficiencies between ultrasound-ONSD/ETD ratio, ultrasound-ONSD, CT-ONSD/ETD ratio, and ICP were 0.613, 0.498, and 0.688, respectively (P < 0.05). The area under the curve (AUC) values of the receiver operating characteristic (ROC) curve for the ultrasound-ONSD/ETD ratio and CT-ONSD/ETD ratio were 0.920 (95% CI 0.877-0.964) and 0.896 (95% CI 0.856-0.931), respectively. The corresponding threshold values were 0.25 (sensitivity of 90%, specificity of 82.3%) and 0.25 (sensitivity of 85.7%, specificity of 83.3%), respectively.
CONCLUSION: The ratio of ONSD to ETD tested by ultrasound may be a reliable indicator for predicting intracranial hypertension in TBI patients.

Entities:  

Keywords:  Eyeball transverse diameter; Intracranial hypertension; Optic nerve ultrasound; Traumatic brain injury

Mesh:

Year:  2020        PMID: 31218637     DOI: 10.1007/s12028-019-00762-z

Source DB:  PubMed          Journal:  Neurocrit Care        ISSN: 1541-6933            Impact factor:   3.210


  3 in total

Review 1.  Cerebral Fat Embolism: Recognition, Complications, and Prognosis.

Authors:  Daniel Agustín Godoy; Mario Di Napoli; Alejandro A Rabinstein
Journal:  Neurocrit Care       Date:  2018-12       Impact factor: 3.210

2.  Effect of posttraumatic serum thyroid hormone levels on severity and mortality of patients with severe traumatic brain injury.

Authors:  Babak Malekpour; Ali Mehrafshan; Forough Saki; Zahed Malekmohammadi; Nasrin Saki
Journal:  Acta Med Iran       Date:  2012

3.  Intracranial Pressure Monitoring: Invasive versus Non-Invasive Methods-A Review.

Authors:  P H Raboel; J Bartek; M Andresen; B M Bellander; B Romner
Journal:  Crit Care Res Pract       Date:  2012-06-08
  3 in total
  8 in total

Review 1.  Management of Elevated Intracranial Pressure: a Review.

Authors:  Abhinav R Changa; Barry M Czeisler; Aaron S Lord
Journal:  Curr Neurol Neurosci Rep       Date:  2019-11-26       Impact factor: 5.081

Review 2.  Ultrasound Detection of Intracranial Hypertension in Brain Injuries.

Authors:  Livio Vitiello; Giulio Salerno; Maddalena De Bernardo; Olga D'Aniello; Luigi Capasso; Giuseppe Marotta; Nicola Rosa
Journal:  Front Med (Lausanne)       Date:  2022-06-30

3.  Ultrasonic Assessment of Optic Nerve Sheath Diameter in Patients at Risk of Sepsis-Associated Brain Dysfunction: A Preliminary Report.

Authors:  Piotr F Czempik; Jakub Gąsiorek; Aleksandra Bąk; Łukasz J Krzych
Journal:  Int J Environ Res Public Health       Date:  2020-05-22       Impact factor: 3.390

4.  Optic nerve sheath diameter and optic nerve sheath diameter/eyeball transverse diameter ratio in prediction of malignant progression in ischemic stroke.

Authors:  Yuan Guo; Yinjuan Chen; Chaoxiong Shen; Daofeng Fan; Xiaohong Hu; Jiaojiao Duan; Yangui Chen
Journal:  Front Neurol       Date:  2022-09-08       Impact factor: 4.086

5.  Optic nerve sheath diameter is associated with outcome in severe Covid-19.

Authors:  Jakob Pansell; Peter C Rudberg; Max Bell; Ola Friman; Charith Cooray
Journal:  Sci Rep       Date:  2022-10-14       Impact factor: 4.996

Review 6.  Optic nerve sheath diameter and spaceflight: defining shortcomings and future directions.

Authors:  Dylan A Fall; Andrew G Lee; Eric M Bershad; Larry A Kramer; Thomas H Mader; Jonathan B Clark; Mohammad I Hirzallah
Journal:  NPJ Microgravity       Date:  2022-10-06       Impact factor: 4.970

7.  The clinical and prognostic values of optic nerve sheath diameter and optic nerve sheath diameter/eyeball transverse diameter ratio in comatose patients with supratentorial lesions.

Authors:  Sha Zhu; Chao Cheng; Dianjiang Zhao; Yuanli Zhao; Xianzeng Liu; Jun Zhang
Journal:  BMC Neurol       Date:  2021-07-02       Impact factor: 2.474

8.  Mean value of B-mode optic nerve sheath diameter as an indicator of increased intracranial pressure: a systematic review and meta-analysis.

Authors:  Lisandro Montorfano; Qian Yu; Stephen J Bordes; Shankarapryan Sivanushanthan; Raul J Rosenthal; Miguel Montorfano
Journal:  Ultrasound J       Date:  2021-07-02
  8 in total