OBJECTIVES: Timely diagnosis and treatment of increased intracranial pressure can decrease morbidity and prevent mortality. The present meta-analysis aims to determine the mean value of the ONSD measured in patients with various elevated ICP etiologies under different clinical settings, as well as comparing the value of ONSD between patients with and without elevated ICP.Entities:
Keywords: Intracranial pressure; Optic nerve sheath; Optic nerve sheath diameter; Point-of-care ultrasound; Trauma; ocular ultrasound; traumatic brain injury
Year: 2021 PMID: 34215966 PMCID: PMC8253877 DOI: 10.1186/s13089-021-00235-5
Source DB: PubMed Journal: Ultrasound J ISSN: 2524-8987
Fig. 1Flow-diagram of manuscript screening and selection
Baseline characteristics of included studies
| Study/year | Region | Design | Sample size | Mean | Ultrasound brand | Clinical setting | Diagnosis | Etiology | Measurement technique |
|---|---|---|---|---|---|---|---|---|---|
| Aduayi 2015 [ | Nigeria | Prospective | 69 | 5.7 | Mindray DC-6 | Mixed | CT | Mixed | 3 mm behind the globe; 3 times per eye; averaged |
| Altayar 2020 [ | Saudi Arabia | Prospective | 28 | 6.6 | Unspecified | ICU | Inv | Trauma | 3 mm posterior to the globe in transverse and sagittal planes in both eyes; average diameter was recorded |
| Bhadari 2019 [ | India | Prospective | 57 | 5.8 | Unspecified | OR | Inv | Hydrocephalus | 3 mm behind the posterior sclera |
| Blaivas 2003 [ | USA | Prospective | 14 | 6.27 | Unspecified | ED | CT | Mixed | 3 mm posterior to the globe for both eyes and then averaged. |
| Bäuerle 2011 [ | Finland | Prospective | 10 | 6.4 | Philips iU22 | Mixed | LP | IIH | 3 mm behind the papilla. Measured 3 times and then averaged. |
| Chen 2019 [ | China | Prospective | 29 | 4.53 | DelicaMVU-6300 | Mixed | LP | Mixed | 3 mm behind the globe; averaged two measurements: one sagittal and the other in the transverse plane |
| del Saz-Saucedo 2016 [ | Spain | Prospective | 19 | 6.76 | Toshiba AplioXG | Mixed | LP | IIH | Transverse plane |
| Du 2020 [ | China | Prospective | 49 | 5.7 | Sonosite | ICU | Inv | Trauma | 3 mm behind the globe; transverse plane; averaged two eyes. |
| Geeraerts 2007 [ | France | Prospective | 15 | 6.3 | HP Sonos 5500 | ICU | Inv | Trauma | 3 mm behind the globe; one sagittal and one transverse |
| Goel 2008 [ | India | Prospective | 73 | 5.8 | Unspecified | Mixed | CT | Trauma | 3 mm behind the globe; one sagittal and one transverse; averaged |
| Hanafi 2019 [ | Iran | Prospective | 62 | 6.06 | SONOSCAPE-SSI 6000 | ED | CT | Trauma | 3 mm posterior to the globe; 3 times on each eye in an axial region; averaged. |
| Kimberly 2008 [ | USA | Prospective | 8 | 5.4 | Sonosite Micromaxx | Mixed | Inv | Mixed | 3 mm posterior to the orbit; axial image; six measurements; averaged. |
| Komut 2016 [ | Turkey | Prospective | 50 | 5.4 | Toshiba Aplio 500 Platinum | ED | CT | Mixed | 3 mm proximal to the optic disc; in transverse and sagittal planes. |
| Mohson 2019 [ | Iraq | Prospective | 40 | 5.6558 | Philips HD11XE | Clinic | LP | Mixed | 3 mm posterior to the globe; transverse. |
| Moretti 2009 [ | Italy | Prospective | 19 | 6.2 | Hitachi EUB 405 | ICU | Inv | Trauma | 3 mm behind the globe; one sagittal and one transverse. |
| Nash 2015 [ | USA | Prospective | 9 | 5.8 | SonoSite M-Turbo | Mixed | Inv | Trauma | 3 mm posterior to the optic disk; longitudinal and transverse. |
| Rehman 2016 [ | Pakistan | Cross-sectional | 13 | 6.61 | Toshiba Xario 200 | Mixed | LP | IIH | 3 mm behind the retina; 3 readings were averaged. |
| Shirodikar 2014 [ | India | Prospective | 35 | 5.43 | Unspecified | Mixed | MRI | Mixed | 3 mm behind the globe; averaging three readings from each eye. |
| Tarzamni 2016 [ | Iran | Prospective | 30 | 5.48 | Aloka Model Prosound 3500 | Mixed | CT | Mixed | 3 mm posterior to the globe; transverse and sagittal; averaged. |
| Ussahgij 2020 [ | Thailand | Prospective | 29 | 5.3 | SonoSite M-Turbo | ED | CT | Mixed | 3 mm posterior. |
| Wang 2015 [ | China | Cross-sectional | 101 | 4.58 | Philips iU22 | Mixed | LP | Mixed | 3 mm posterior to the orbit; transverse and sagittal; repeated twice; averaged |
| Zoerle 2020 [ | Italy | Prospective | 20 | 6.44 | Phillips iE33 | ICU | Inv | Trauma | 3 mm behind the globe; transverse and sagittal; repeated twice; averaged |
Fig. 2Optic nerve sheath diameter (ONSD) measured by ultrasound (US) between patients with elevated intracranial pressure (ICP) and normal cohort (A). Funnel plot and Egger’s test evaluating publication bias (B)
Fig. 3Optic nerve sheath diameter (ONSD) measured by ultrasound (US) stratified by clinical settings where measurement was taken place. ICU Intensive care unit, ED Emergency Department, OR operating room
Fig. 4Optic nerve sheath diameter (ONSD) measured by ultrasound (US) stratified by the diagnostic method of increased intracranial pressure (ICP). MRI magnetic resonance imaging, CT computed tomography, LP lumbar puncture, Inv invasive intracranial monitoring
Fig. 5Optic nerve sheath diameter (ONSD) measured by ultrasound (US) stratified by etiology of elevated intracranial pressure