Literature DB >> 31217006

In vitro study of effects of aging and processing conditions on colour change in maxillofacial silicone elastomers.

Ebru Demet Cifter1, Meltem Ozdemir-Karatas2, Adem Cinarli3, Erkan Sancakli2, Ali Balik2, Gulumser Evlioglu2.   

Abstract

BACKGROUND: The inherent colour change in maxillofacial silicone elastomers becomes perceptible 6-12 months after fabrication. Determining the factors that accelerate the degradation of the prosthesis can help the clinicians increase its life span. Therefore, the aim of the study was to investigate the effect of time passage, processing temperature, and molding-stone colour on the colour change of maxillofacial silicone elastomers after darkroom storage for 6000 h.
METHODS: A total of ten study molds, each incorporating ten specimen gaps were fabricated using five different colors of dental stones. The gaps were filled with coloured Cosmesil M511 maxillofacial silicone elastomer. Five of the study molds, one of each stone color, were processed at room temperature (25 °C) for 24 h while the remainder were vulcanized at 100 °C for 1 h. Two stainless-steel molds were also fabricated to obtain a total of twenty control-group specimens of the same dimensions that were processed under the same conditions as the study molds. Colour measurements of the vulcanized silicone samples were performed using a Konica Minolta spectrophotometer. Initial measurements were obtained after the blocks were removed from the molds and the final measurements were recorded 6000 h after storage in the dark at 25 °C and 40% relative humidity. The CIEDE2000 colour-difference formula was used to measure the changes in the colour. One-way and two-way ANOVA, and an independent-sample t-test were used for statistical assessments.
RESULTS: For every group, the colour change exceeded the perceptible thresholds. Thus, either the vulcanization temperature or the colour of the molding stone has a significant effect on the colour change over time. Those samples vulcanized in green and white molding stones at 100 °C exhibited a significantly higher ∆L*, ∆a*, and ∆b* values relative to the samples vulcanized at room temperature.
CONCLUSION: The molding-stone colour and vulcanization temperature both affect the degree of colour change after storage in a dark environment. The L*, a*, and b* values for the maxillofacial silicone elastomers are influenced by the direction of the increase or decrease according to the selected colour. This effect varies as the temperature increases.

Entities:  

Keywords:  Colour; Dark room; Dental stone; Elastomer; Maxillofacial; Silicone; Time passage

Mesh:

Substances:

Year:  2019        PMID: 31217006      PMCID: PMC6585052          DOI: 10.1186/s12903-019-0798-1

Source DB:  PubMed          Journal:  BMC Oral Health        ISSN: 1472-6831            Impact factor:   2.757


  37 in total

1.  Color stability and colorant effect on maxillofacial elastomers. Part III: weathering effect on color.

Authors:  S P Haug; C J Andres; B K Moore
Journal:  J Prosthet Dent       Date:  1999-04       Impact factor: 3.426

2.  Accelerated color change in a maxillofacial elastomer with and without pigmentation.

Authors:  J J Gary; E F Huget; L D Powell
Journal:  J Prosthet Dent       Date:  2001-06       Impact factor: 3.426

3.  Effects of environmental factors on maxillofacial elastomers: Part III--Physical properties.

Authors:  S P Haug; C J Andres; C A Munoz; M Okamura
Journal:  J Prosthet Dent       Date:  1992-10       Impact factor: 3.426

4.  Effect of chemical disinfection and accelerated aging on color stability of maxillofacial silicone with opacifiers.

Authors:  Marcelo Coelho Goiato; Marcela Filié Haddad; Aldiéris Alves Pesqueira; Amália Moreno; Daniela Micheline Dos Santos; Lisiane Cristina Bannwart
Journal:  J Prosthodont       Date:  2011-08-31       Impact factor: 2.752

5.  Color stability of facial prostheses.

Authors:  J C Lemon; M S Chambers; M L Jacobsen; J M Powers
Journal:  J Prosthet Dent       Date:  1995-12       Impact factor: 3.426

6.  Color changes in dry-pigmented maxillofacial elastomer resulting from ultraviolet light exposure.

Authors:  M W Beatty; G K Mahanna; K Dick; W Jia
Journal:  J Prosthet Dent       Date:  1995-11       Impact factor: 3.426

7.  Stain resistance of maxillofacial materials.

Authors:  A Koran; J M Powers; P J Lepeak; R G Craig
Journal:  J Dent Res       Date:  1979-05       Impact factor: 6.116

8.  Color stability of elastomers for maxillofacial appliances.

Authors:  R G Craig; A Koran; R Yu; J Spencer
Journal:  J Dent Res       Date:  1978 Sep-Oct       Impact factor: 6.116

9.  Comparison of the CIELab and CIEDE2000 color difference formulas.

Authors:  Cristina Gómez-Polo; María Portillo Muñoz; Mari Cruz Lorenzo Luengo; Purificación Vicente; Purificanción Galindo; Ana María Martín Casado
Journal:  J Prosthet Dent       Date:  2015-09-26       Impact factor: 3.426

10.  Effect of vulcanization temperature and dental stone colour on colour degradation of maxillofacial silicone elastomers.

Authors:  Ebru Demet Cifter; Meltem Ozdemir-Karatas; Emrah Baca; Adem Cinarli; Ali Balik; Erkan Sancakli; Bilge Gokcen-Rohlig
Journal:  BMC Oral Health       Date:  2017-03-31       Impact factor: 2.757

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.