| Literature DB >> 31217005 |
Elham Soltanimehr1, Ehsan Bahrampour2, Zeynab Yousefvand3.
Abstract
BACKGROUND: This study aimed to assess the efficacy of a 980-nm diode and 10.6-μm CO2 laser accompanied by tricalcium phosphate-5% sodium fluoride (fTCP) and casein phosphopeptide amorphous calcium phosphate (CPP-ACP) for the remineralization of primary teeth.Entities:
Keywords: CO2 laser; Casein Phosphopeptide amorphous calcium phosphate; Diode laser; Microhardness; Porosity; Remineralization; Tricalcium phosphate fluoride
Mesh:
Substances:
Year: 2019 PMID: 31217005 PMCID: PMC6585004 DOI: 10.1186/s12903-019-0813-6
Source DB: PubMed Journal: BMC Oral Health ISSN: 1472-6831 Impact factor: 2.757
Materials used in this study and their composition
| Material | Composition | Manufacturer |
|---|---|---|
| Tooth Mousse (Recaldent) | Pure water, Glycerol, CPP-ACP, D-sorbitol, CMC-Na, Propylene glycol, Silicone dioxide, Titanium dioxide, Xylitol, Phosphoric acid, Zinc oxide, Sodium Saccharin, Ethyl p-hydroxybenzoate, Magnesium oxide, Guar gum, Propyl p-hydroxybenzoate, Butyl p- hydroxybenzoate | GC, Tokyo, Japan |
| Clinpro White Varnish | Tri-Calcium-Phosphate (TCP), Alcohol, Rosin, Sodium fluoride, Xylitol, Sodium Fluoride | 3 M, Hackensack, NJ, USA |
Fig. 1a Primary microhardness of samples according to the type of laser and material used. b Mean microhardness after demineralization according to the type of laser and type of material. c Microhardness after remineralization according to the type of laser and material. d Percentage of remineralization according to the type of laser and material used
Mean and standard deviation of porosity in the groups
| Group | AFM1 | AFM2 | AFM3 | |||
|---|---|---|---|---|---|---|
| Mean | Standard deviation | Mean | Standard deviation | Mean | Standard deviation | |
| No material | 13.06 | .21 | 115.48 | 5.88 | 101.90 | 3.24 |
| fTCP | 13.33 | 1.54 | 118.35 | 3.59 | 92.74 | 6.69 |
| CPP-ACP | 13.38 | .90 | 121.79 | 6.38 | 96.92 | 1.34 |
| No laser | 12.86 | .23 | 121.57 | 7.42 | 101.34 | 3.75 |
| Diode | 14.09 | 1.08 | 117.69 | 3.78 | 96.14 | 5.35 |
| CO2 | 12.83 | .73 | 116.36 | 5.18 | 94.09 | 5.97 |
AFM1 AFM before demineralization, AFM2 AFM after demineralization, AFM3 AFM after remineralization
Fig. 2a–c Enamel demineralization (5 × 5 μm); mean porosity: 111.65 nm; distance between the highest and lowest point: 290.4 nm (d–f) 5 × 5 μm area treated with fTCP and diode laser; mean porosity: 96.74 nm; distance between the highest and lowest point: 208.1 nm