PURPOSE: To use magnetic resonance imaging (MRI) to investigate the knee joint of children following arthroscopic fixation of osteochondral lesions using bioabsorbable nails and to correlate these imaging findings with time from arthroscopic treatment and with risk factors at the time of imaging.
MATERIALS AND METHODS: Our study included postarthroscopic MRI studies from 58 children (mean age at arthroscopy, 13.8 + 2.1 years) who have undergone bioabsorbable nail fixation of unstable osteochondral lesions between February 1, 2011 and September 30, 2017. All studies were retrospectively reviewed for broken nails, intra-articular debris, and internal knee derangement. Demographic information and information pertaining to active symptoms was obtained from both MRI questionnaire that was completed at the time of the study and clinical note that preceded the study. Marginal logistic regression models estimated using generalized estimating equations (GEE) were used to identify factors associated with a broken nail and joint effusion.
RESULTS: A total of 104 postoperative studies were reviewed, which included 60 with symptoms and 44 without symptoms. Nail breakage was present in 38 (36.6%) studies and associated with presence of symptoms (OR 2.43, p = 0.036) and effusion (OR 2.76, p = 0.025). An effusion was present in 40 (38.5%) studies which decreased with increasing time from treatment (OR 0.89, p = 0.007) and increased with symptoms (OR 10.87, p < 0.001). Meniscal tear was present on 8 (7.7%) and chondral irregularity on 14 (13.5%) studies.
CONCLUSION: Broken nail, effusion, and less commonly, meniscal tears and chondral irregularity, are all complications that can arise following fixation of osteochondral lesions with bioabsorbable nails. MRI can serve as a valuable tool in assessing these complications.

Entities:  

Keywords:  Children; Implant; Knee; MRI; OCD; Osteochondral fracture; Osteochondritis dissecans; Smartnail

Mesh:

Year:  2019        PMID: 31214727     DOI: 10.1007/s00256-019-03258-1

Source DB:  PubMed          Journal:  Skeletal Radiol        ISSN: 0364-2348            Impact factor:   2.199


  2 in total

1.  Arthroscopic Fixation of Knee Osteochondritis Dissecans With Interlinked Knotless All-Suture Anchors.

Authors:  Jim C Hsu; Duong H Tran
Journal:  Arthrosc Tech       Date:  2022-05-11

2.  Biomechanical Analysis of Unstable Osteochondral Fragment Fixation Using Three Different Techniques: Osteochondral Plug, Bioabsorbable Pin, and Suture Anchor with Tape.

Authors:  Shizuka Sasaki; Shohei Yamauchi; Eiji Sasaki; Yuka Kimura; Akane Takahashi; Yasuyuki Ishibashi
Journal:  Arthrosc Sports Med Rehabil       Date:  2022-02-01
  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.