Purpose: To compare the initial fixation strength of osteochondral fragment fixations using osteochondral plugs, bioabsorbable pins, and knotless suture anchors.Entities:
Year: 2022 PMID: 35494288 PMCID: PMC9042741 DOI: 10.1016/j.asmr.2021.08.019
Source DB: PubMed Journal: Arthrosc Sports Med Rehabil ISSN: 2666-061X
Fig 1The medial femoral condyle was cut 5 mm deep (A and B), and the metal screw that was inserted in the osteochondral fragment was directed perpendicular to the articular surface (C), so that the osteochondral fragment could be reduced anatomically and clamped during tensile load testing, with tensile load applied perpendicular to the osteotomy plane (D).
Fig 2The fixation scheme and photo showing the procedure to fix osteochondral fragment created by cutting the articular surface (dotted line) of the porcine femoral condyle. The osteochondral fragment was fixed with two osteochondral plugs (A), with four full-threaded bioabsorbable pins (B), and with three suture anchors with 2-0 tape (C). The location of the osteochondral plug and device is indicated by arrows.
Fig 3Setting of materials in the testing machine. A metal screw was inserted into the osteochondral fragment and clamped during tensile load testing. The tensile load is applied perpendicular to the osteotomy plane. The location of fixation device is indicated by arrows. This figure shows the testing in suture anchor group.
The Results of the Tensile Load at a Displacement of 1 and 2 mm and Ultimate Failure Load
| Osteochondral Plug Group | Bioabsorbable Pin Group | Suture Anchor Group | ||||
|---|---|---|---|---|---|---|
| Mean ± SD (range) | 95% CI | Mean ± SD (range) | 95% CI | Mean ± SD (range) | 95% CI | |
| Tensile load at a displacement of 1 mm (N) | 30.8 ± 18.9 (6.8-63.8) | 9.0-52.6 | 49.8 ± 28.4 (7.0-93.9) | 17.1-82.4 | 55.3 ± 20.2 (23.8-75.7) | 32.0-78.6 |
| Tensile load at a displacement of 2 mm (N) | 37.0 ± 26.0 (12.0-82.4) | 7.0-67.0 | 52.8 ± 24.1 (13.0-87.3) | 25.0-80.5 | 100.4 ± 21.5 (72.4-134.7) | 75.7-125.1 |
| Ultimate failure load (N) | 40.8 ± 25.8 (12.0-85.4) | 11.2-70.4 | 59.9 ± 29.1 (14.2-98.2) | 26.5-93.3 | 188.4 ± 41.7 (145.2-246.2) | 140.5-236.3 |
CI, confidence interval; SD, standard deviation.
P < .05 (vs. the osteochondral plug group);
P < .05 (vs the bioabsorbable pin group).