| Literature DB >> 31206667 |
Ana Laura Bemvenuti Jacques1, Maíra Kerpel Dos Santos1, Renata Pereira Limberger1.
Abstract
A liquid chromatography-mass spectrometry method using dried oral fluid spots was developed and validated for the simultaneous quantification of cocaine, benzoylecgonine, cocaethylene, amphetamine, and 3,4-methylenedioxymethamphetamine. The oral fluid was applied to a Whatman 903 grade paper and submitted to a drying time of 2.5 h. The extraction procedure was optimized by chemometric approach using simplex centroid design. Spots were extracted with a mixture of acetonitrile, buffer, and methanol. Calibration curves covered a linear concentration range of 40-500 ng/mL. Validation parameters of linearity, precision, accuracy, selectivity, carryover, matrix effects, and stability were evaluated and showed satisfactory results. Spot homogeneity was also satisfactory, with less than 15% of deviation from nominal concentration. Spot volume did not influence accuracy when less than 100 μL of the sample was applied to the spot. The validation of the proposed method suggests a potential application in different scenarios in toxicology.Entities:
Keywords: analytic sample preparation methods; analytical chemistry techniques; dried oral fluid spot; forensic science; forensic toxicology; investigative techniques; substance abuse detection
Mesh:
Substances:
Year: 2019 PMID: 31206667 DOI: 10.1111/1556-4029.14112
Source DB: PubMed Journal: J Forensic Sci ISSN: 0022-1198 Impact factor: 1.832