Literature DB >> 31203871

Antibacterial efficacy of handrubbing for 15 versus 30 seconds: EN 1500-based randomized experimental study with different loads of Staphylococcus aureus and Escherichia coli.

D Pires1, H Soule2, F Bellissimo-Rodrigues3, M E A de Kraker2, D Pittet4.   

Abstract

OBJECTIVES: Compliance with the World Health Organization 'how to handrub' action is suboptimal. Simplifying the hand-hygiene action may improve practice. However, it is crucial to preserve antibacterial efficacy. We tested the non-inferiority of 15 versus 30 seconds handrubbing for Staphylococcus aureus and Escherichia coli contamination at different loads, using hand-size customized alcohol-based handrub (ABHR) volumes.
METHODS: In an EN1500-based study, 18 health-care workers (HCWs) with extensive experience in hand hygiene rubbed hands with a hand-size customized volume of isopropanol 60% v/v. They repeated the following sequence: hand contamination (E. coli or S. aureus; broth containing 108 or 106 CFU/mL); baseline fingertips sampling; handrubbing (15 or 30 seconds); re-sampling. The main outcome was log10 CFU corrected reduction factor (cRF) on HCWs' hands, applying a generalized linear mixed model with a random intercept for subject.
RESULTS: The median cRF was 2.1 log10 (interquartile range 1.50-3.10). After fitting the model, cRF was significantly higher for S. aureus compared with E. coli but there was no significant effect for duration of handrubbing or contamination fluid concentration. Fifteen seconds of handrubbing was non-inferior to 30 (-0.06 log10, 95% CI -0.34 to 0.22; EN1500 0.60 log10 non-inferiority margin). This was confirmed in all pre-specified subgroups.
CONCLUSION: Among experienced HCWs using a hand-size customized volume of ABHR, handrubbing for 15 seconds was non-inferior to 30 seconds in reducing bacterial load, irrespective of type of bacteria or contamination fluid concentration. This provides further support for a shorter, 15-seconds, hand-hygiene action.
Copyright © 2018 European Society of Clinical Microbiology and Infectious Diseases. Published by Elsevier Ltd. All rights reserved.

Entities:  

Keywords:  Antimicrobial efficacy; Hand hygiene; Handrubbing; Handrubbing duration; Patient safety; WHO ‘how to handrub’

Mesh:

Substances:

Year:  2018        PMID: 31203871     DOI: 10.1016/j.cmi.2018.10.012

Source DB:  PubMed          Journal:  Clin Microbiol Infect        ISSN: 1198-743X            Impact factor:   8.067


  3 in total

1.  Effect of Wearing a Novel Electronic Wearable Device on Hand Hygiene Compliance Among Health Care Workers: A Stepped-Wedge Cluster Randomized Clinical Trial.

Authors:  Daniela Pires; Angele Gayet-Ageron; Chloe Guitart; Yves-Alain Robert; Carolina Fankhauser; Ermira Tartari; Alexandra Peters; Funda Tymurkaynak; Simon Fourquier; Herve Soule; Rene Beuchat; Fernando Bellissimo-Rodrigues; Yves Martin; Walter Zingg; Didier Pittet
Journal:  JAMA Netw Open       Date:  2021-02-01

2.  Systematic review on factors influencing the effectiveness of alcohol-based hand rubbing in healthcare.

Authors:  Lesley Price; Lucyna Gozdzielewska; Julius Cesar Alejandre; Annelysse Jorgenson; Emma Stewart; Didier Pittet; Jacqui Reilly
Journal:  Antimicrob Resist Infect Control       Date:  2022-01-24       Impact factor: 4.887

3.  Rapid-killing efficacy substantiates the antiseptic property of the synergistic combination of carvacrol and nerol against nosocomial pathogens.

Authors:  Thirupathi Kasthuri; Thirukannamangai Krishnan Swetha; James Prabhanand Bhaskar; Shunmugiah Karutha Pandian
Journal:  Arch Microbiol       Date:  2022-09-02       Impact factor: 2.667

  3 in total