Wrist-Sensor Pulse Oximeter Enables Prolonged Patient Monitoring in Chronic Lung Diseases.

Alexander Guber1,2, Gali Epstein Shochet1, Sarah Kohn3, David Shitrit4,5.   

Abstract

Pulse oximetry is an important diagnostic tool in monitoring and treating both in-patients and ambulatory patients. Modern pulse oximeters exploit different body sites (eg fingertip, forehead or earlobe). All those are bulky and uncomfortable, resulting in low patient compliance. Therefore, we evaluated the accuracy and precision of a wrist-sensor pulse oximeter (Oxitone-1000, Oxitone Medical) vs. the traditional fingertip device. Fifteen healthy volunteers and 23 patients were recruited. The patient group included chronic obstructive pulmonary disease (COPD) (N = 8), asthma (N = 6), sarcoidosis (N = 5) and others. Basic demographic data, skin tone type, smoking status and medical history were recorded. Blood oxygen level (SpO2) and pulse-rate values were determined by a non-invasive pulse oximeter (Reference, a conventional FDA-cleared fingertip pulse oximeter) and by Oxitone-1000. All tests were performed in singleton and in a blinded fashion. The measurements were done in sitting and standing positions, as well as after a 6-min walk test. The mean age was 60.4 ± 9.83 years, 55% were male. No significant differences were observed between the wrist-sensor and the traditional fingertip pulse oximeters in all tested parameters. Mean SpO2 was 96.45% vs. 97.18% and the mean pulse was 74.64 vs. 74.6 bpm (Oxitone-1000 vs. Reference, respectively, p < 0.0001). Precision rate was 2.28472% and the accuracy was met (Arms -Root mean-square-error < 3%). The Oxitone-1000 is both accurate and precise for SpO2 and pulse measurements during daily activities of pulmonary patients, and is not inferior to standard devices for spot checking or short period examinations. Its wrist-sensor design is comfortable and provides the advantage of extended use.

Entities:  

Keywords:  6-min walk test; COPD; Device assessment; Pulse oximetry

Mesh:

Substances:

Year:  2019        PMID: 31201528     DOI: 10.1007/s10916-019-1317-2

Source DB:  PubMed          Journal:  J Med Syst        ISSN: 0148-5598            Impact factor:   4.460


  18 in total

1.  ATS statement: guidelines for the six-minute walk test.

Authors: 
Journal:  Am J Respir Crit Care Med       Date:  2002-07-01       Impact factor: 21.405

2.  British Thoracic Society guidelines for home oxygen use in adults.

Authors:  Maxine Hardinge; Joe Annandale; Simon Bourne; Brendan Cooper; Angela Evans; Daryl Freeman; Angela Green; Sabrine Hippolyte; Vikki Knowles; William MacNee; Lynn McDonnell; Kathy Pye; Jay Suntharalingam; Vandana Vora; Tom Wilkinson
Journal:  Thorax       Date:  2015-06       Impact factor: 9.139

3.  Risk indexes for exacerbations and hospitalizations due to COPD.

Authors:  Dennis E Niewoehner; Yuliya Lokhnygina; Kathryn Rice; Ware G Kuschner; Amir Sharafkhaneh; George A Sarosi; Peter Krumpe; Karen Pieper; Steven Kesten
Journal:  Chest       Date:  2007-01       Impact factor: 9.410

4.  Effects of skin pigmentation on pulse oximeter accuracy at low saturation.

Authors:  Philip E Bickler; John R Feiner; John W Severinghaus
Journal:  Anesthesiology       Date:  2005-04       Impact factor: 7.892

Review 5.  Short term ambulatory oxygen for chronic obstructive pulmonary disease.

Authors:  J M Bradley; B O'Neill
Journal:  Cochrane Database Syst Rev       Date:  2005-04-18

6.  Continuous oxygen monitoring--a better way to prescribe long-term oxygen therapy.

Authors:  Zhiwen Zhu; Randal K Barnette; Kevin M Fussell; R Michael Rodriguez; Angelo Canonico; Richard W Light
Journal:  Respir Med       Date:  2005-11       Impact factor: 3.415

7.  Prediction of exacerbation onset in chronic obstructive pulmonary disease patients.

Authors:  Hans Christian Riis; Morten H Jensen; Simon Lebech Cichosz; Ole K Hejlesen
Journal:  J Med Eng Technol       Date:  2016-01-08

8.  Effect of oxygen on health quality of life in patients with chronic obstructive pulmonary disease with transient exertional hypoxemia.

Authors:  Mika L Nonoyama; Dina Brooks; Gordon H Guyatt; Roger S Goldstein
Journal:  Am J Respir Crit Care Med       Date:  2007-04-19       Impact factor: 21.405

9.  Dark skin decreases the accuracy of pulse oximeters at low oxygen saturation: the effects of oximeter probe type and gender.

Authors:  John R Feiner; John W Severinghaus; Philip E Bickler
Journal:  Anesth Analg       Date:  2007-12       Impact factor: 5.108

10.  Chronic obstructive pulmonary disease. National clinical guideline on management of chronic obstructive pulmonary disease in adults in primary and secondary care.

Authors: 
Journal:  Thorax       Date:  2004-02       Impact factor: 9.139

View more
  3 in total

1.  Implementation of ISO/IEEE 11073 PHD SpO2 and ECG Device Specializations over Bluetooth HDP following Health Care Profile for Smart Living.

Authors:  Alexandra Cristobal-Huerta; Angel Torrado-Carvajal; Cristina Rodriguez-Sanchez; Juan Antonio Hernandez-Tamames; Maria Luaces; Susana Borromeo
Journal:  Sensors (Basel)       Date:  2022-07-28       Impact factor: 3.847

2.  Commercial smartwatch with pulse oximeter detects short-time hypoxemia as well as standard medical-grade device: Validation study.

Authors:  Jakub Rafl; Thomas E Bachman; Veronika Rafl-Huttova; Simon Walzel; Martin Rozanek
Journal:  Digit Health       Date:  2022-10-11

Review 3.  An Evaluation of Biometric Monitoring Technologies for Vital Signs in the Era of COVID-19.

Authors:  Christine Manta; Sneha S Jain; Andrea Coravos; Dena Mendelsohn; Elena S Izmailova
Journal:  Clin Transl Sci       Date:  2020-10-12       Impact factor: 4.689

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.