Literature DB >> 31199403

Fiber-based polarization-sensitive optical coherence tomography of a minimalistic system configuration.

Sucbei Moon, Yusi Miao, Zhongping Chen.   

Abstract

We present a very simple method of constructing a polarization-sensitive optical coherence tomography (PS-OCT) system. An ordinary fiber-based swept-source OCT system was reconfigured for PS-OCT by adding a long section of polarization-maintaining fiber in the sample arm. Two polarization modes of a large group-delay difference formed spatially distinguished polarization channels. The depth-encoded information on the polarization states was retrieved by an amplitude-based analysis. We found that our method provides an economic scheme of PS-OCT. It demonstrates that an ordinary OCT system can be easily reconfigured for PS-OCT imaging if it has sufficient margins in the imaging range.

Entities:  

Year:  2019        PMID: 31199403      PMCID: PMC6922310          DOI: 10.1364/OL.44.003150

Source DB:  PubMed          Journal:  Opt Lett        ISSN: 0146-9592            Impact factor:   3.776


  16 in total

1.  Depth-resolved birefringence and differential optical axis orientation measurements with fiber-based polarization-sensitive optical coherence tomography.

Authors:  Shuguang Guo; Jun Zhang; Lei Wang; J Stuart Nelson; Zhongping Chen
Journal:  Opt Lett       Date:  2004-09-01       Impact factor: 3.776

2.  High-speed fiber based polarization-sensitive optical coherence tomography of in vivo human skin.

Authors:  C E Saxer; J F de Boer; B H Park; Y Zhao; Z Chen; J S Nelson
Journal:  Opt Lett       Date:  2000-09-15       Impact factor: 3.776

3.  Numerical dispersion compensation for Partial Coherence Interferometry and Optical Coherence Tomography.

Authors:  A Fercher; C Hitzenberger; M Sticker; R Zawadzki; B Karamata; T Lasser
Journal:  Opt Express       Date:  2001-12-03       Impact factor: 3.894

4.  Imaging thermally damaged tissue by Polarization Sensitive Optical Coherence Tomography.

Authors:  J De Boer; S Srinivas; A Malekafzali; Z Chen; J Nelson
Journal:  Opt Express       Date:  1998-09-14       Impact factor: 3.894

5.  Polarization-sensitive spectral-domain optical coherence tomography using a single line scan camera.

Authors:  Barry Cense; Mircea Mujat; Teresa C Chen; B H Park; Johannes F de Boer
Journal:  Opt Express       Date:  2007-03-05       Impact factor: 3.894

6.  Polarization Effects in Optical Coherence Tomography of Various Biological Tissues.

Authors:  Johannes F de Boer; Shyam M Srinivas; B Hyle Park; Tuan H Pham; Zhongping Chen; Thomas E Milner; J Stuart Nelson
Journal:  IEEE J Sel Top Quantum Electron       Date:  1999 Jul-Aug       Impact factor: 4.544

7.  Passive optical module for polarization-sensitive optical coherence tomography systems.

Authors:  Sylvain Rivet; Manuel J Marques; Adrian Bradu; Adrian Podoleanu
Journal:  Opt Express       Date:  2017-06-26       Impact factor: 3.894

8.  Phase-stability optimization of swept-source optical coherence tomography.

Authors:  Sucbei Moon; Zhongping Chen
Journal:  Biomed Opt Express       Date:  2018-10-09       Impact factor: 3.732

9.  Characterization of spectral-domain OCT with autocorrelation interference response for axial resolution performance.

Authors:  Sucbei Moon; Yueqiao Qu; Zhongping Chen
Journal:  Opt Express       Date:  2018-03-19       Impact factor: 3.894

10.  Single camera based spectral domain polarization sensitive optical coherence tomography.

Authors:  Bernhard Baumann; Erich Götzinger; Michael Pircher; Christoph K Hitzenberger
Journal:  Opt Express       Date:  2007-02-05       Impact factor: 3.894

View more
  1 in total

1.  Intravascular polarization-sensitive optical coherence tomography based on polarization mode delay.

Authors:  Yan Li; Sucbei Moon; Yuchen Jiang; Saijun Qiu; Zhongping Chen
Journal:  Sci Rep       Date:  2022-04-27       Impact factor: 4.996

  1 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.