Literature DB >> 31198665

Ab-interno trabeculotomy-related glaucoma surgeries.

Masaki Tanito1, Masato Matsuo1.   

Abstract

Reductions of intraocular pressure during trabeculotomy result from relieving the resistance to aqueous flow by cleavage of the trabecular meshwork and inner walls of Schlemm's canal at the point of outflow resistance of the aqueous humor. Since trabeculotomy does not result in bleb formation, development of late-onset sight-threatening complications, such as hypotony maculopathy and endophthalmitis, that are associated occasionally with trabeculectomy develop less frequently after trabeculotomy. The ab-interno approach is used in several new procedures, including the Trabectome, Kahook Dual Blade, microhook abinterno trabeculotomy, and 360° suture trabeculotomy, instead of the ab-externo approach as in conventional trabeculotomy. These newly developed novel, minimally invasive, and trabeculotomy-related glaucoma surgeries can be good options for certain glaucoma cases, including early-stage open-angle glaucoma, developmental glaucoma, and glaucoma in elderly patients.

Entities:  

Keywords:  Ab-externo trabeculotomy; Kahook Dual Blade; Trabectome; microhook ab-interno trabeculotomy; minimally invasive glaucoma surgery; suture ab-interno trabeculotomy

Year:  2019        PMID: 31198665      PMCID: PMC6557068          DOI: 10.4103/tjo.tjo_38_19

Source DB:  PubMed          Journal:  Taiwan J Ophthalmol        ISSN: 2211-5056


Introduction

The goal of trabeculotomy is reduction of the intraocular pressure (IOP) in patients with glaucoma.[1234] The mechanism by which this is accomplished may be by elimination of the aqueous flow resistance by cleavage of the trabecular meshwork (TM) and inner walls of Schlemm's canal at the point of outflow resistance of the aqueous humor. The ab-externo approach that involves incision of the TM after a scleral flap is created has been used traditionally to perform trabeculotomy in combination with metal trabeculotomes.[1234] A new technique, i.e., the ab-interno approach, for performing trabeculotomy has been reported recently, in which the TM is incised or excised using specialized devices under direct observation of the anterior-chamber angle structure. These novel trabeculotomy approach included the Trabectome procedure during which the surgeon removes the TM using a small diathermy/irrigation/aspiration handpiece [Figure 1a];[5] the Kahook Dual Blade is used to excise the TM in a strip using a curette with two blades [Figure 1b];[67] microhook ab-interno trabeculotomy, which uses a small metal hook to incise the TM [Figure 1c];[8910] and ab-interno 360° suture trabeculotomy/gonioscopy-assisted transluminal trabeculotomy, by which the entire TM is incised using a suture after circumferential insertion of the suture into Schlemm's canal [Figure 1d].[1112]
Figure 1

Various devices for novel trabeculotomy-related surgeries. (a) The Trabectome provided by Kowa Company Ltd. (http://www.kowa.co.jp). (b) The Kahook Dual Blade provided by JFC sale Plan (http://www.jfcsp.co.jp). (c) The Tanito ab interno Trabeculotomy Microhook provided by Inami and Co., Ltd. (http://inami.co.jp). (d) The Chin trabeculotomy suture provided by Handaya Co., Ltd. (http://www.handaya.co.jp)

Various devices for novel trabeculotomy-related surgeries. (a) The Trabectome provided by Kowa Company Ltd. (http://www.kowa.co.jp). (b) The Kahook Dual Blade provided by JFC sale Plan (http://www.jfcsp.co.jp). (c) The Tanito ab interno Trabeculotomy Microhook provided by Inami and Co., Ltd. (http://inami.co.jp). (d) The Chin trabeculotomy suture provided by Handaya Co., Ltd. (http://www.handaya.co.jp)

Microhook Ab-Interno Trabeculotomy, A Novel Minimally Invasive Glaucoma Surgery

Three different microhooks are used during microhook ab-interno trabeculotomy. A straight [M-2215S, Figure 1c] hook is used to incise the nasal angle, and angled-right [M-2215R, Figure 1c] and angled-left [M-2215 L, Figure 1c] hooks (all from Inami and Co., Ltd.) are used to incise the temporal angle. A Swan Jacob gonioprism lens (Ocular Instruments) is used to observe the angle opposite to the corneal port, and a microhook is inserted into the anterior chamber through the corneal port [Figure 2a and b]. The microhook tip then is inserted into Schlemm's canal and moved circumferentially to incise the inner wall of the canal and TM over 3 clock hours. Trabeculotomy then is performed in the opposite angle using the same procedure by insertion of the microhook through another corneal port. We recommend perforating the meshwork by gently sliding and not stabbing the tip into the meshwork surface to minimize damage to the outer wall of Schlemm's canal when inserting the tip of the hook into Schlemm's canal. After inserted the tip of the hook, the depth of the tip can be visualized thorough the TM. When the tip cannot be visualized through the TM, this usually indicates that the tip is too deep. With adequate direction and depth, only minor resistance is encountered when the tip is moved circumferentially; any resistance usually indicates that the tip is too deep. Avoiding iatrogenic tissue damage around the TM requires careful monitoring of the correct insertion, direction, and depth of the tip of the hook. Intraoperative use of microscope-integrated optical coherence tomography (OCT) (RESCAN 700, Carl Zeiss Meditec Japan) in combination with a gonioprism[13] or by anterior-segment OCT (Casia 2, Tomey Corporation) postoperatively can visualize correct opening of the TM [Figure 3a and b].[9] The surgical video is available at https://www.youtube.com/watch? v = VPWhsEsfrn8.[14]
Figure 2

Surgical procedure of microhook ab-interno trabeculotomy. (a) Observation of the anterior-chamber angle using a Swan-Jacob gonioprism lens shows the trabecular meshwork and that inner wall of Schlemm's canal is incised circumferentially using the tip of the microhook inserted into the anterior chamber through the small corneal incision. (b) A schematic drawing of the meshwork incision by the tip of the hook. This schema is provided by Inami Co. Ltd

Figure 3

Anterior-chamber angle findings after microhook ab-interno trabeculotomy. (a) Observation of the anterior-chamber angle using anterior-segment optical coherence tomography (Casia 2, Tomey). A trabeculotomy cleft is seen in both the temporal and nasal angles (arrows) postoperatively in the right eye. (b) Observation of the entire anterior-chamber angle using a 360° gonioscope (GS-1, Nidek).[21] Small but interrupted peripheral anterior synechiae (arrows) are seen postoperatively in the right eye

Surgical procedure of microhook ab-interno trabeculotomy. (a) Observation of the anterior-chamber angle using a Swan-Jacob gonioprism lens shows the trabecular meshwork and that inner wall of Schlemm's canal is incised circumferentially using the tip of the microhook inserted into the anterior chamber through the small corneal incision. (b) A schematic drawing of the meshwork incision by the tip of the hook. This schema is provided by Inami Co. Ltd Anterior-chamber angle findings after microhook ab-interno trabeculotomy. (a) Observation of the anterior-chamber angle using anterior-segment optical coherence tomography (Casia 2, Tomey). A trabeculotomy cleft is seen in both the temporal and nasal angles (arrows) postoperatively in the right eye. (b) Observation of the entire anterior-chamber angle using a 360° gonioscope (GS-1, Nidek).[21] Small but interrupted peripheral anterior synechiae (arrows) are seen postoperatively in the right eye An initial case series reported that at the final 6-month examination, microhook ab-interno trabeculotomy alone decreased the IOP from 25.9 mmHg preoperatively to 14.7 mmHg postoperatively, a 43% decrease.[9] Microhook ab-interno trabeculotomy combined with cataract surgery decreased the IOP from 16.4 mmHg preoperatively to 11.8 mmHg postoperatively at the final 9.5-month examination, a 28% decrease.[10] The complications reported included transient IOP spikes, cataract progression, vitreous hemorrhages, and macular edema.[910]

Features of Conventional and Novel Trabeculotomy-Related Surgeries

The features of the new trabeculotomy-related surgeries are shown in Table 1. Since the ab-interno approach does not require conjunctival and scleral incisions, the new trabeculotomy-related procedures are minimally invasive to the ocular surface, which allows these procedures to be performed safely in the eyes with scleral thinning.[8] The smaller surgical incisions created in the ocular surface with ab-interno trabeculotomy-related procedures cause less induced postoperative astigmatism than astigmatism that develops following trabeculectomy.[15] Direct visualization of the anterior-chamber angle achieved using a gonioprism lens during ab-interno trabeculotomy facilitates easier identification of Schlemm's canal compared with identification of the anterior-chamber angle under the scleral flap during conventional ab-externo trabeculotomy. The extent of the trabeculotomy (90–120°) the conventional ab-externo trabeculotomy [Figure 4a], the Trabectome procedure, and the Kahook Dual Blade [Figure 4b] is wider, i.e., 180–240° for microhook ab-interno trabeculotomy [Figure 4c] and 360° with suture trabeculotomy when a suture is inserted successfully into the entire circumference of Schlemm's canal [Figure 4d]. In a perfusion study of autopsy eyes, the investigators reported that incisions in the TM that extended for 1, 4, and 12 clock hours eliminated 30%, 44%, and 51%, respectively, of the outflow resistance at 7 mmHg of perfusion pressure and 30%, 56%, and 72%, respectively, of the outflow resistance at 25 mmHg of perfusion pressure.[16] Those findings indicated that wider trabeculotomies combined with a novel trabeculotomy-related procedure other than conventional ab-externo trabeculotomy are advantageous. However, the future comparative studies are needed to corroborate the results. The Kahook Dual Blade requires a single-use handpiece, and the Trabectome procedure requires a single-use handpiece and a surgical machine, all of which increase the surgical costs compared with other procedures.
Table 1

Comparisons among conventional trabeculotomy and recent trabecular meshwork surgeries

ProcedureTrabeculotomy ab externoGoniotomyTrabectomeKahook Dual BladeMicrohook ab-interno trabeculotomy360° ab-interno trabeculotomy
Trabeculotomy extent1/4 circumference1/4 circumference1/4 circumference1/4 circumference1/2-2/3 circumference~Entire circumference
Ocular surface invasiveness++MinimalMinimalMinimalMinimalMinimal
Procedural difficultyDifficultDifficultEasyModerateModerateDifficult
Reason for difficultyRequire Schlemm’s canal identificationRequire incision depth controlLarge device tip, difficulty in strip excisionRequire left-handed procedureDifficulty in entire circumference suture insertion
Surgical costLowLowHighModerateLowLow

This table was adopted from my previous publication[20] with English translation with the permission of the journal

Figure 4

The typical extents of the incisions created in traditional ab-externo trabeculotomy and novel trabeculotomy-related glaucoma surgeries. (a) Conventional ab-externo trabeculotomy. (b) The Trabectome and Kahook Dual Blade. (c) Microhook ab-interno trabeculotomy. (d) Suture ab-interno trabeculotomy. The red arcs indicate the extent of the trabeculotomy, the blue lines the corneal side ports, and the blue box the scleral flap. These panels are adopted from our previous publication[20] with modification with the permission of the journal

Comparisons among conventional trabeculotomy and recent trabecular meshwork surgeries This table was adopted from my previous publication[20] with English translation with the permission of the journal The typical extents of the incisions created in traditional ab-externo trabeculotomy and novel trabeculotomy-related glaucoma surgeries. (a) Conventional ab-externo trabeculotomy. (b) The Trabectome and Kahook Dual Blade. (c) Microhook ab-interno trabeculotomy. (d) Suture ab-interno trabeculotomy. The red arcs indicate the extent of the trabeculotomy, the blue lines the corneal side ports, and the blue box the scleral flap. These panels are adopted from our previous publication[20] with modification with the permission of the journal

Indications for Ab-Interno Trabeculotomy-Related Surgeries

The indications and contraindications of trabeculotomy-related surgeries are shown in Table 2. Trabeculotomy is the first-choice procedure for most steroid-induced and developmental glaucomas. Early-stage open-angle glaucoma including primary open-angle and exfoliation glaucomas are also candidates for trabeculotomy. Compared with trabeculotomy, trabeculectomy, the gold-standard glaucoma surgery, results in the need for more frequent postoperative procedures, e.g., laser suture lysis and needling, and possibly is associated with bleb-related complications. The IOP reduction achieved with trabeculotomy might be enhanced by older age and simultaneous cataract surgery.[3417] Since elderly patients may have difficulties traveling frequently for hospital visits, they can be good candidates for trabeculotomy.[18] Although the surgical indications for ab-externo and ab-interno surgeries are the same, the safer profile of the latter, i.e., less invasiveness of the ocular surface, less difficult surgical procedure, and shorter surgical duration, enables surgeons to perform these novel procedures in eyes with an earlier stage of glaucoma than conventional trabeculotomy.
Table 2

Indications for trabeculotomy-related procedures

Indication
 Early-stage open-angle glaucoma (i.e., primary open-angle glaucoma, exfoliation glaucoma, steroid-induced glaucoma)
 Developmental glaucoma without corneal opacity
 Glaucoma accompanying visual disturbance due to cataract (combined cataract and glaucoma surgeries)
 Primary angle-closure glaucoma (combined cataract and glaucoma surgeries)
 Glaucoma in elderly patients (difficulty with frequent hospital access, life expectancy)
Contraindication
 Ocular inflammation
 Neovascular glaucoma
 Aphakic glaucoma
 Vitreous collapse into the anterior chamber
 Advanced glaucoma

This table is adopted from my previous publication[20] with English translation with the permission of the journal

Indications for trabeculotomy-related procedures This table is adopted from my previous publication[20] with English translation with the permission of the journal

Financial support and sponsorship

Nil.

Conflicts of interest

The microhooks used were codeveloped by Masaki Tanito, MD, PhD, and Inami and Co., Ltd. (Tokyo, Japan) and provided by Inami and Co., Ltd. Dr. Tanito receives royalties from Inami and Co., Ltd.
  17 in total

1.  Microhook ab interno trabeculotomy, a novel minimally invasive glaucoma surgery, in eyes with open-angle glaucoma with scleral thinning.

Authors:  Masaki Tanito; Ichiya Sano; Yoshifumi Ikeda; Etsuko Fujihara
Journal:  Acta Ophthalmol       Date:  2015-09-26       Impact factor: 3.761

2.  Outflow resistance of enucleated human eyes at two different perfusion pressures and different extents of trabeculotomy.

Authors:  R Rosenquist; D Epstein; S Melamed; M Johnson; W M Grant
Journal:  Curr Eye Res       Date:  1989-12       Impact factor: 2.424

3.  Preclinical investigation of ab interno trabeculectomy using a novel dual-blade device.

Authors:  Leonard K Seibold; Jeffrey R Soohoo; David A Ammar; Malik Y Kahook
Journal:  Am J Ophthalmol       Date:  2012-12-04       Impact factor: 5.258

4.  Factors leading to reduced intraocular pressure after combined trabeculotomy and cataract surgery.

Authors:  Masaki Tanito; Akihiro Ohira; Etsuo Chihara
Journal:  J Glaucoma       Date:  2002-02       Impact factor: 2.503

5.  Gonioscopy-assisted transluminal trabeculotomy, ab interno trabeculotomy: technique report and preliminary results.

Authors:  Davinder S Grover; David G Godfrey; Oluwatosin Smith; William J Feuer; Ildamaris Montes de Oca; Ronald L Fellman
Journal:  Ophthalmology       Date:  2014-01-10       Impact factor: 12.079

6.  Surgical outcome of combined trabeculotomy and cataract surgery.

Authors:  M Tanito; A Ohira; E Chihara
Journal:  J Glaucoma       Date:  2001-08       Impact factor: 2.503

7.  Clinical results with the Trabectome for treatment of open-angle glaucoma.

Authors:  Don S Minckler; George Baerveldt; Marina Ramirez Alfaro; Brian A Francis
Journal:  Ophthalmology       Date:  2005-06       Impact factor: 12.079

8.  Short-term results of microhook ab interno trabeculotomy, a novel minimally invasive glaucoma surgery in Japanese eyes: initial case series.

Authors:  Masaki Tanito; Ichiya Sano; Yoshifumi Ikeda; Etsuko Fujihara
Journal:  Acta Ophthalmol       Date:  2016-11-02       Impact factor: 3.761

9.  Prospective, noncomparative, nonrandomized case study of short-term outcomes of 360° suture trabeculotomy ab interno in patients with open-angle glaucoma.

Authors:  Tomoki Sato; Akira Hirata; Takanori Mizoguchi
Journal:  Clin Ophthalmol       Date:  2015-01-05

10.  Optical Coherence Tomography Observation of Gonio Structures during Microhook Ab Interno Trabeculotomy.

Authors:  Masaki Tanito
Journal:  J Ophthalmol       Date:  2017-08-06       Impact factor: 1.909

View more
  11 in total

1.  Outcomes of Microhook ab Interno Trabeculotomy in Consecutive 36 Eyes with Uveitic Glaucoma.

Authors:  Noriyuki Sotani; Sentaro Kusuhara; Wataru Matsumiya; Mina Okuda; Sotaro Mori; Rei Sotani; Kyung Woo Kim; Ryuto Nishisho; Makoto Nakamura
Journal:  J Clin Med       Date:  2022-06-29       Impact factor: 4.964

2.  Proportion of Glaucoma Types and Surgeries Among Young, Pre-Old, Old, and Oldest-Old Age Groups or Different Sex Groups.

Authors:  Masaki Tanito; Yotaro Matsuoka
Journal:  Clin Ophthalmol       Date:  2022-06-07

3.  Comparison of outflow facility before and after the microhook ab interno trabeculotomy.

Authors:  Masaki Tanito; Aika Tsutsui; Kaoru Manabe; Mihoko Mochiji
Journal:  Eye (Lond)       Date:  2021-04-12       Impact factor: 3.775

4.  Observation of Gonio Structures during Microhook Ab Interno Trabeculotomy Using a Novel Digital Microscope with Integrated Intraoperative Optical Coherence Tomography.

Authors:  Akiko Ishida; Kazunobu Sugihara; Tomoki Shirakami; Aika Tsutsui; Kaoru Manabe; Masaki Tanito
Journal:  J Ophthalmol       Date:  2020-07-17       Impact factor: 1.909

5.  Characterization of Peripheral Anterior Synechiae Formation After Microhook Ab-interno Trabeculotomy Using a 360-Degree Gonio-Camera.

Authors:  Masato Matsuo; Yuina Inomata; Nana Kozuki; Masaki Tanito
Journal:  Clin Ophthalmol       Date:  2021-04-19

6.  Reasons for choice of glaucoma surgery in eyes not treated with anti-glaucoma medications.

Authors:  Kazunobu Sugihara; Hiroki Fukuda; Tetsuro Omura; Masaki Tanito
Journal:  BMC Ophthalmol       Date:  2022-03-30       Impact factor: 2.209

7.  Three-dimensional heads-up surgery in ab-interno trabeculotomy: Image processing-assisted trabeculotomy.

Authors:  Takafumi Suzuki; Takashi Fujishiro; Koichiro Sugimoto; Makoto Aihara
Journal:  PLoS One       Date:  2022-02-10       Impact factor: 3.240

8.  Comparison of Postoperative Hyphemas between Microhook Ab Interno Trabeculotomy and iStent Using a New Hyphema Scoring System.

Authors:  Akiko Ishida; Sho Ichioka; Yuji Takayanagi; Aika Tsutsui; Kaoru Manabe; Masaki Tanito
Journal:  J Clin Med       Date:  2021-11-26       Impact factor: 4.241

9.  Automated Focal Plane Merging From a Stack of Gonioscopic Photographs Using a Focus-Stacking Algorithm.

Authors:  Masato Matsuo; Nana Kozuki; Yuina Inomata; Yoshiki Kumagai; Ryosuke Shiba; Koji Hamaguchi; Masaki Tanito
Journal:  Transl Vis Sci Technol       Date:  2022-04-01       Impact factor: 3.048

10.  Fellow-Eye Comparison between Phaco-Microhook Ab-Interno Trabeculotomy and Phaco-iStent Trabecular Micro-Bypass Stent.

Authors:  Yuji Takayanagi; Sho Ichioka; Akiko Ishida; Aika Tsutsui; Masaki Tanito
Journal:  J Clin Med       Date:  2021-05-14       Impact factor: 4.241

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.